Deep Learning for Improved Precision and Reproducibility of Left Ventricular Strain in Echocardiography: A Test-Retest Study

被引:0
|
作者
Salte, Ivar M. [1 ,2 ,7 ]
Ostvik, Andreas [3 ,4 ,5 ]
Olaisen, Sindre H. [3 ,4 ]
Karlsen, Sigve [2 ,6 ]
Dahlslett, Thomas [6 ]
Smistad, Erik [3 ,4 ,5 ]
Eriksen-Volnes, Torfinn K. [3 ,4 ,10 ]
Brunvand, Harald [6 ]
Haugaa, Kristina H. [2 ,7 ,8 ,9 ]
Edvardsen, Thor [2 ,7 ]
Dalen, Havard [3 ,4 ,10 ,11 ]
Lovstakken, Lasse [3 ,4 ]
Grenne, Bjornar [3 ,4 ,10 ]
机构
[1] Hosp Southern Norway, Dept Med, Kristiansand, Norway
[2] Univ Oslo, Fac Med, Oslo, Norway
[3] Norwegian Univ Sci & Technol, Ctr Innovat Ultrasound Solut, Trondheim, Norway
[4] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[5] SINTEF Digital, Med Image Anal, Hlth Res, Trondheim, Norway
[6] Hosp Southern Norway, Dept Med, Arendal, Norway
[7] Oslo Univ Hosp, ProCardio Ctr Innovat, Dept Cardiol, Rikshosp, Oslo, Norway
[8] Karolinska Inst, Fac Med, Stockholm, Sweden
[9] Karolinska Univ Hosp, Cardiovasc Div, Stockholm, Sweden
[10] St Olavs Univ Hosp, Clin Cardiol, Postbox 3250, NO-7006 Trondheim, Norway
[11] Levanger Hosp, Nord Trondelag Hosp Trust, Levanger, Norway
关键词
Left ventricular function; Echocardiography; Strain; Reproducibility; Artificial intelligence; SPECKLE-TRACKING ECHOCARDIOGRAPHY; GLOBAL LONGITUDINAL STRAIN; EUROPEAN ASSOCIATION; CONSENSUS DOCUMENT; EXPERT CONSENSUS; AMERICAN SOCIETY; TASK-FORCE; QUANTIFICATION; GUIDELINES; AGREEMENT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Assessment of left ventricular (LV) function by echocardiography is hampered by modest test-retest reproducibility. A novel artificial intelligence (AI) method based on deep learning provides fully automated mea-surements of LV global longitudinal strain (GLS) and may improve the clinical utility of echocardiography by reducing user-related variability. The aim of this study was to assess within-patient test-retest reproducibility of LV GLS measured by the novel AI method in repeated echocardiograms recorded by different echocardi-ographers and to compare the results to manual measurements.Methods: Two test-retest data sets (n = 40 and n = 32) were obtained at separate centers. Repeated record-ings were acquired in immediate succession by 2 different echocardiographers at each center. For each data set, 4 readers measured GLS in both recordings using a semiautomatic method to construct test-retest inter-reader and intrareader scenarios. Agreement, mean absolute difference, and minimal detectable change (MDC) were compared to analyses by AI. In a subset of 10 patients, beat-to-beat variability in 3 cardiac cycles was assessed by 2 readers and AI.Results: Test-retest variability was lower with AI compared with interreader scenarios (data set I: MDC = 3.7 vs 5.5, mean absolute difference = 1.4 vs 2.1, respectively; data set II: MDC = 3.9 vs 5.2, mean absolute differ-ence = 1.6 vs 1.9, respectively; all P < .05). There was bias in GLS measurements in 13 of 24 test-retest inter-reader scenarios (largest bias, 3.2 strain units). In contrast, there was no bias in measurements by AI. Beat-to-beat MDCs were 1,5, 2.1, and 2.3 for AI and the 2 readers, respectively. Processing time for analyses of GLS by the AI method was 7.9 6 2.8 seconds.Conclusion: A fast AI method for automated measurements of LV GLS reduced test-retest variability and removed bias between readers in both test-retest data sets. By improving the precision and reproducibility, AI may increase the clinical utility of echocardiography. (J Am Soc Echocardiogr 2023;36:788-99.)
引用
收藏
页码:788 / 799
页数:12
相关论文
共 50 条
  • [21] INTER-MODALITY AGREEMENT AND TEST-RETEST REPRODUCIBILITY OF CMR AND ECHOCARDIOGRAPHY FOR ASSESSING MYOCARDIAL DEFORMATION IN TYPE 2 DIABETES MELLITUS
    Alfuhied, Aseel
    Gulsin, Gaurav S.
    Brady, Emer M.
    Yeo, Jian L.
    Parke, Kelly
    Marsh, Anna-Marie
    Arnold, Jayanth Ranjit
    McCann, Gerry P.
    Singh, Anvesha
    HEART, 2021, 107 : A2 - A3
  • [22] Interstudy reproducibility of parameters of left ventricular diastolic function: A Doppler echocardiography study
    Palmieri, V
    Arezzi, E
    Sabatella, M
    Celentano, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (11) : 1128 - 1135
  • [23] Measurement of serotonin transporter binding with PET and [11C]MADAM:: A test-retest reproducibility study
    Lundberg, Johan
    Halldin, Christer
    Farde, Lars
    SYNAPSE, 2006, 60 (03) : 256 - 263
  • [24] Using deep learning method to identify left ventricular hypertrophy on echocardiography
    Yu, Xiang
    Yao, Xinxia
    Wu, Bifeng
    Zhou, Hong
    Xia, Shudong
    Su, Wenwen
    Wu, Yuanyuan
    Zheng, Xiaoye
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (04): : 759 - 769
  • [25] Test-retest variability of volumetric right ventricular measurements using real-time three-dimensional echocardiography
    Van Der Zwaan, H. B.
    Geleijnse, M. L.
    Soliman, O. I. I.
    Mcghie, J. S.
    Wiegers-Groeneweg, E. J. A.
    Helbing, W. A.
    Roos-Hesselink, J. W.
    Meijboom, F. J.
    EUROPEAN HEART JOURNAL, 2011, 32 : 442 - 443
  • [26] Test-Retest Variability of Volumetric Right Ventricular Measurements Using Real-Time Three-Dimensional Echocardiography
    van der Zwaan, Heleen B.
    Geleijnse, Marcel L.
    Soliman, Osama I. I.
    McGhie, Jackie S.
    Wiegers-Groeneweg, Ellen J. A.
    Helbing, Willem A.
    Roos-Hesselink, Jolien W.
    Meijboom, Folkert J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) : 671 - 679
  • [27] Multimodal deep learning enhances diagnostic precision in left ventricular hypertrophy
    Soto, Jessica Torres
    Hughes, J. Weston
    Sanchez, Pablo Amador
    Perez, Marco
    Ouyang, David
    Ashley, Euan A.
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2022, 3 (03): : 380 - 389
  • [28] TEST-RETEST REPRODUCIBILITY OF DIETARY PATTERNS ASSESSED WITH A FOOD FREQUENCY QUESTIONNAIRE (KOMPAN): STUDY IN POLISH ADOLESCENTS AND ADULTS
    Kowalkowska, Joanna
    Wadolowska, Lidia
    Czarnocinska, Jolanta
    Czlapka-Matyasik, Magdalena
    Galinski, Grzegorz
    Jezewska-Zychowicz, Marzena
    Bronkowska, Monika
    Dlugosz, Anna
    Loboda, Dorota
    Wyka, Joanna
    ANNALS OF NUTRITION AND METABOLISM, 2017, 71 : 1043 - 1044
  • [29] A test-retest multisite reproducibility study of cardiovascular four-dimensional flow MRI without respiratory gating
    Zhang, Y.
    Tang, X-Q
    Ma, Y.
    Shi, H-F
    Wang, X.
    Wang, X-Q
    Pan, C-J
    CLINICAL RADIOLOGY, 2021, 76 (03) : 236.e1 - 236.e8
  • [30] Reliability of the 123I-mIBG heart/mediastinum ratio: Results of a multicenter test-retest reproducibility study
    Bateman, Timothy M.
    Ananthasubramaniam, Karthikeyan
    Berman, Daniel S.
    Gerson, Myron
    Gropler, Robert
    Henzlova, Milena
    Mendoza, Fernando
    Miyamoto, Michael
    Shah, Mahesh
    Weiland, Frederick
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (05) : 1555 - 1565