Efficacy of a newly developed guidewire for selective biliary access

被引:2
|
作者
Park, Do Hyun [1 ]
Han, Joung-Ho [2 ]
Lee, Tae Hoon [3 ]
Yang, Jae Kook [3 ]
Lee, Ji Sung [4 ,5 ]
Lee, Yong Hun [6 ]
Takenaka, Mamoru [7 ]
Park, Sang-Heum [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Internal Med, Coll Med, Seoul, South Korea
[2] Chungbuk Natl Univ, Chungbuk Natl Univ Hosp, Dept Internal Med, Coll Med, Cheongju, South Korea
[3] Soonchunhyang Univ, Cheonan Hosp, Dept Internal Med, Coll Med, 31 Sooncheonhyang 6 Gil, Cheonan 31151, Chungcheongnam, South Korea
[4] Univ Ulsan, Asan Inst Life Sci, Clin Res Ctr, Asan Med Ctr,Coll Med, Seoul, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Clin Epidemiol & Biostat, Coll Med, Seoul, South Korea
[6] Sungwon Med Co Ltd, Res & Dev, Cheongju, South Korea
[7] Kindai Univ, Fac Med, Dept Gastroenterol & Hepatol, Osaka, Japan
关键词
POST-ERCP PANCREATITIS; BILE-DUCT; CANNULATION; 0.025-INCH; SPHINCTEROTOME; MULTICENTER;
D O I
10.1038/s41598-023-34846-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A clinical efficacy study of 0.025-inch guidewires (GWs) according to mechanical property analysis has not been reported yet. This study was designed to evaluate the clinical efficacy of a newly developed 0.025-inch GW for biliary access according to the basic mechanical property. Commercially available 0.025-inch GWs were in vitro tested based on parameters of mechanical property. Patients with naive papilla requiring diagnostic or therapeutic ERCP were randomly assigned to an experimental 0.025-inch newly developed GW or a control 0.025-inch GW group. Technical success rate of wire-guided cannulation (WGC), difficult biliary cannulation (DBC), and adverse event rates were measured in this multicenter randomized trial. The technical success rate of primary WGC was 79.1% (151 of 191) in the experimental group and 70.8% (131 of 185) in the control group (95% two-sided confidence interval: 8.25%; p < 0.001; for a noninferiority margin of 15%). The technical success rate including cross-over to each other was also non-inferior. However, the chi-square test showed a statistical difference (81.7% vs. 68.1%; p = 0.002). Median biliary cannulation time was shorter in the experimental group (53 s vs. 77 s; p = 0.047). The rate of DBC was more frequent in the control group (34.6% vs. 50.3% p = 0.002). Multivariate analysis revealed that control group was one of contributing factors for DBC. Overall rate of post-ERCP pancreatitis was not different (4.7% vs. 8.6%; p = 0.125). WGC using a newly developed GW with superior physical performance GW in a bench test showed similar clinical efficacy and the rate of DBC was significantly lower in experimental GW.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Pancreatic Duct Guidewire-indwelling Method for Patients Resistant to Selective Biliary Cannulation and Usefulness of Pre-cut Papillotomy following Unsuccessful Biliary Cannulation with Pancreatic Duct Guidewire-indwelling Method
    Sakai, Yuji
    Tsuyuguchi, Toshio
    Mikata, Rintaro
    Sugiyama, Harutoshi
    Yasui, Shin
    Eto, Reiko
    Fujimoto, Tatsuya
    Tamura, Ryo
    Togo, Seiko
    Tada, Motohisa
    Ishihara, Takeshi
    Yokosuka, Osamu
    HEPATO-GASTROENTEROLOGY, 2011, 58 (107) : 698 - 704
  • [42] A guidewire-assisted biopsy technique to assist advancement through a biliary stricture to perform selective mapping biopsy
    Kawakami, Hiroshi
    Kuwatani, Masaki
    Abe, Yoko
    Kawahata, Shuhei
    Kawakubo, Kazumichi
    Kubo, Kimitoshi
    Sakamoto, Naoya
    ENDOSCOPY, 2015, 47 : E217 - E218
  • [43] Digital single-operator cholangioscopy: a useful tool for selective guidewire placements across complex biliary strictures
    Arne Bokemeyer
    Dina Gross
    Markus Brückner
    Tobias Nowacki
    Dominik Bettenworth
    Hartmut Schmidt
    Hauke Heinzow
    Iyad Kabar
    Hansjoerg Ullerich
    Frank Lenze
    Surgical Endoscopy, 2019, 33 : 731 - 737
  • [44] Cholangioscopy in Recurrent Cholangitis after Liver Transplantation: Selective Guidewire Cannulation of Non-anastomotic Biliary Stricture
    Gambaccini, Dario
    Ruggiero, Luigi
    Marciano, Emanuele
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2022, 31 (04) : 381 - 381
  • [45] Digital single-operator cholangioscopy: a useful tool for selective guidewire placements across complex biliary strictures
    Bokemeyer, Arne
    Gross, Dina
    Brueckner, Markus
    Nowacki, Tobias
    Bettenworth, Dominik
    Schmidt, Hartmut
    Heinzow, Hauke
    Kabar, Iyad
    Ullerich, Hansjoerg
    Lenze, Frank
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (03): : 731 - 737
  • [46] EUS-guided suprapapillary puncture for safe selective biliary access
    Matsushita, Mitsunobu
    Uchida, Kazushige
    Okazaki, Kazuichi
    GASTROINTESTINAL ENDOSCOPY, 2007, 66 (04) : 865 - 866
  • [47] A newly developed kit for dental apical root resorption detection: efficacy and acceptability
    Tan, Jun Hong Steven
    Yazid, Farinawati
    Abu Kasim, Nurfathiha
    Ariffin, Shahrul Hisham Zainal
    Wahab, Rohaya Megat Abdul
    BMC ORAL HEALTH, 2024, 24 (01)
  • [48] The Efficacy of a Newly Developed Cueing Device for Gait Mobility in Parkinson's Disease
    Suputtitada, Areerat
    Chen, Carl P. C.
    Pongmala, Chatkaew
    Sriyudthsak, Mana
    Wilhelm, Agnes
    Somboon, Pakpum
    Janssen, Jessie
    Richards, Jim
    PARKINSONS DISEASE, 2022, 2022
  • [49] Efficacy and tolerance of the newly developed cephalosporin cefquinome in bacterial respiratory diseases of pigs
    Rose, M
    Wissler, R
    Zschiesche, E
    Thomas, E
    TIERARZTLICHE PRAXIS AUSGABE GROBTIERE NUTZTIERE, 2000, 28 (06): : 331 - 336
  • [50] A newly developed kit for dental apical root resorption detection: efficacy and acceptability
    Jun Hong Steven Tan
    Farinawati Yazid
    Nurfathiha Abu Kasim
    Shahrul Hisham Zainal Ariffin
    Rohaya Megat Abdul Wahab
    BMC Oral Health, 24