Comparison of the radiographic outcomes and total blood loss between pinless navigation and conventional method in minimally invasive total knee arthroplasty

被引:2
|
作者
Yen, Shih-Hsiang [1 ]
Lin, Po-Chun [1 ]
Wang, Jun-Wen [1 ]
机构
[1] Chang Gung Univ, Kaohsiung Chang Gung Mem Hosp, Coll Med, Dept Orthopaed Surg, 123 Ta Pei Rd, Kaohsiung, Taiwan
关键词
Navigation; Total knee arthroplasty; Blood loss; TRANEXAMIC ACID; COMPONENT ALIGNMENT; REPLACEMENT; SURGERY; FEMUR; LIMB;
D O I
10.1186/s13018-023-03534-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Computer-assisted surgical navigation has been used in total knee arthroplasty (TKA) procedures for years trying to the accuracy of prosthesis placement. We conducted this prospective randomized clinical trial to compare the accuracy of the radiographic parameters of the prosthesis, total blood loss (TBL), and related complications, between a new pinless navigation system (Stryker OrthoMap Express Knee Navigation) and conventional method in patients undergoing minimally invasive (MIS) TKA procedures. Patient and methods A consecutive series of 100 patients underwent unilateral primary TKA were randomly assigned into two groups: navigation group and convention group. The radiographic parameters of the knee implant and the alignment of lower limb were measured at 3 months after surgery. TBL was calculated according to Nadler's method. The duplex ultrasonography of both lower limbs was performed in all patients to detect the presence of deep-vein thrombosis (DVT). Results Totally, 94 patients have completed the radiographic measures. Only the coronal femoral component angle in the navigation group (89.12 degrees +/- 1.83 degrees) had significant differences from that in the convention group (90.09 degrees +/- 2.18 degrees) (p = 0.022). There were no differences in the rate of outliers. The mean TBL in the navigation group was 841 +/- 267 mL, which was similar to that in the convention group at 860 +/- 266 mL (p = 0.721). Postoperative DVT risk did not differ between the two groups (2% vs. 0%, p = 0.315). Conclusion This pinless navigation TKA showed a comparable acceptable alignment compared with conventional MIS-TKA. There were no differences regarding postoperative TBL between the two groups.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Minimally invasive navigation-assisted versus conventional total knee arthroplasty: a meta-analysis
    Young-Soo Shin
    Hyun-Jung Kim
    Young-Rok Ko
    Jung-Ro Yoon
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3425 - 3432
  • [32] Comparision of blood loss between computer assisted and conventional total knee arthroplasty
    Mohanlal, Paras Kumar
    Sandiford, Nemandra
    Skinner, John A.
    Samsani, S. R.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (01) : 63 - 66
  • [33] Comparision of blood loss between computer assisted and conventional total knee arthroplasty
    Paras Kumar Mohanlal
    Nemandra Sandiford
    John A. Skinner
    S. R. Samsani
    Indian Journal of Orthopaedics, 2013, 47 : 63 - 66
  • [34] Functional results of navigated minimally invasive and conventional total knee arthroplasty: A comparison in bilateral cases
    Song, Eun Kyoo
    Seon, Jong Keun
    Yoon, Taek Rim
    Park, Sang Jin
    Bae, Bong Hyun
    Cho, Sang Gwon
    ORTHOPEDICS, 2006, 29 (10) : S145 - S147
  • [36] Results of computer assisted navigation in Total Knee Arthroplasty (TKA): Comparison with the conventional method
    Thein, E.
    Loecherbach, C.
    Rousson, V.
    Manueddu, C. A.
    SWISS MEDICAL WEEKLY, 2009, 139 (23-24) : 40S - 40S
  • [37] Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation
    Patrick Weber
    Sandra Utzschneider
    Patrick Sadoghi
    Matthias F. Pietschmann
    Andreas Ficklscherer
    Volkmar Jansson
    Peter E. Müller
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 281 - 288
  • [38] Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation
    Weber, Patrick
    Utzschneider, Sandra
    Sadoghi, Patrick
    Pietschmann, Matthias F.
    Ficklscherer, Andreas
    Jansson, Volkmar
    Mueller, Peter E.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (02) : 281 - 288
  • [39] Functional impact of navigation-assisted minimally invasive total knee arthroplasty
    Seon, JK
    Song, EK
    ORTHOPEDICS, 2005, 28 (10) : S1251 - S1254
  • [40] Minimally invasive revision total knee arthroplasty
    Bonutti, Peter M.
    Seyler, Thorsten M.
    Kester, Mark
    McMahon, Margo
    Mont, Michael A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (446) : 69 - 75