Comparison of the radiographic outcomes and total blood loss between pinless navigation and conventional method in minimally invasive total knee arthroplasty

被引:2
|
作者
Yen, Shih-Hsiang [1 ]
Lin, Po-Chun [1 ]
Wang, Jun-Wen [1 ]
机构
[1] Chang Gung Univ, Kaohsiung Chang Gung Mem Hosp, Coll Med, Dept Orthopaed Surg, 123 Ta Pei Rd, Kaohsiung, Taiwan
关键词
Navigation; Total knee arthroplasty; Blood loss; TRANEXAMIC ACID; COMPONENT ALIGNMENT; REPLACEMENT; SURGERY; FEMUR; LIMB;
D O I
10.1186/s13018-023-03534-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Computer-assisted surgical navigation has been used in total knee arthroplasty (TKA) procedures for years trying to the accuracy of prosthesis placement. We conducted this prospective randomized clinical trial to compare the accuracy of the radiographic parameters of the prosthesis, total blood loss (TBL), and related complications, between a new pinless navigation system (Stryker OrthoMap Express Knee Navigation) and conventional method in patients undergoing minimally invasive (MIS) TKA procedures. Patient and methods A consecutive series of 100 patients underwent unilateral primary TKA were randomly assigned into two groups: navigation group and convention group. The radiographic parameters of the knee implant and the alignment of lower limb were measured at 3 months after surgery. TBL was calculated according to Nadler's method. The duplex ultrasonography of both lower limbs was performed in all patients to detect the presence of deep-vein thrombosis (DVT). Results Totally, 94 patients have completed the radiographic measures. Only the coronal femoral component angle in the navigation group (89.12 degrees +/- 1.83 degrees) had significant differences from that in the convention group (90.09 degrees +/- 2.18 degrees) (p = 0.022). There were no differences in the rate of outliers. The mean TBL in the navigation group was 841 +/- 267 mL, which was similar to that in the convention group at 860 +/- 266 mL (p = 0.721). Postoperative DVT risk did not differ between the two groups (2% vs. 0%, p = 0.315). Conclusion This pinless navigation TKA showed a comparable acceptable alignment compared with conventional MIS-TKA. There were no differences regarding postoperative TBL between the two groups.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of the radiographic outcomes and total blood loss between pinless navigation and conventional method in minimally invasive total knee arthroplasty
    Shih-Hsiang Yen
    Po-Chun Lin
    Jun-Wen Wang
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Blood loss after navigation-assisted minimally invasive total knee arthroplasty
    Eum, Dae Sub
    Lee, Ho Kyu
    Hwang, Seok Young
    Park, Jin Uck
    ORTHOPEDICS, 2006, 29 (10) : S152 - S154
  • [3] Navigation in Minimally Invasive Total Knee Arthroplasty and Total Hip Arthroplasty
    Hafez, Mahmoud A.
    Seel, Michael J.
    Jaramaz, Branislav
    DiGioia, Anthony M., III
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2006, 16 (03) : 207 - 210
  • [4] BLOOD LOSS AFTER MINIMALLY INVASIVE TOTAL KNEE ARTHROPLASTY: EFFECTS OF IMAGELESS NAVIGATION
    Chang, Chih-Wei
    Wu, Po-Ting
    Yang, Chyun-Yu
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (05): : 237 - 242
  • [5] Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty
    Jerry Yongqiang Chen
    Pak Lin Chin
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1827 - 1832
  • [6] Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty
    Chen, Jerry Yongqiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1827 - 1832
  • [7] Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum?
    Günther Maderbacher
    Jens Schaumburger
    Armin Keshmiri
    Magdalena Barthel
    Hans-Robert Springorum
    Benjamin Craiovan
    Joachim Grifka
    Clemens Baier
    International Orthopaedics, 2015, 39 : 455 - 460
  • [8] Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum?
    Maderbacher, Guenther
    Schaumburger, Jens
    Keshmiri, Armin
    Barthel, Magdalena
    Springorum, Hans-Robert
    Craiovan, Benjamin
    Grifka, Joachim
    Baier, Clemens
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (03) : 455 - 460
  • [9] No Difference in Functional Outcomes after Total Knee Arthroplasty with or without Pinless Navigation
    Zhu, Meng
    Chen, Jerry Yongqiang
    Chong, Hwei Chi
    Pang, Hee Nee
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF KNEE SURGERY, 2018, 31 (07) : 649 - 653
  • [10] A New Navigation System for Minimally Invasive Total Knee Arthroplasty
    Yokoyama, Yusuke
    Abe, Nobuhiro
    Fujiwara, Kazuo
    Suzuki, Masahiko
    Nakajima, Yoshikazu
    Sugita, Naohiko
    Mitsuishi, Mamoru
    Nakashima, Yoshio
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2013, 67 (06) : 351 - 358