Thermal parameter inversion of low-heat cement concrete for Baihetan arch dam

被引:5
|
作者
Wang, Feng [1 ,2 ]
Song, Rui [1 ,2 ]
Yu, Hu [1 ,2 ]
Zhang, Ao [1 ,2 ]
Wang, Linwei [1 ,2 ]
Chen, Xia [3 ]
机构
[1] China Three Gorges Univ, Hubei Key Lab Construct & Management Hydropower En, Yichang 443002, Peoples R China
[2] China Three Gorges Univ, Coll Hydraul & Environm Engn, Yichang 443002, Peoples R China
[3] Changjiang River Sci Res Inst, Dept Mat & Struct, Wuhan 430010, Peoples R China
基金
中国国家自然科学基金;
关键词
Arch dam; Concrete thermal parameters; Hybrid swarm intelligence; Inverse analysis; Artificial bee colony; Low-heat cement; ARTIFICIAL BEE COLONY; PARTICLE SWARM; OPTIMIZATION ALGORITHM; MECHANICAL PERFORMANCE; TEMPERATURE-FIELD; DESIGN; TESTS; ABC; INTELLIGENCE; EVOLUTIONARY;
D O I
10.1016/j.engappai.2023.107823
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For the first time, low-heat cement was used in the entire dam section of Baihetan Dam, but the thermal properties of low-heat cement under construction conditions have yet to be fully studied. The thermal parameter values of low-heat cement may differ significantly from the indoor test values or specification values due to factors such as ambient temperature, cooling through water, and surface insulation under actual site conditions. Therefore, in order to obtain more accurate values of the thermal parameters, the hybrid swarm intelligence algorithm and field temperature monitoring data are used to identify the concrete thermal parameters of Baihetan arch dam. To overcome the shortcomings of Particle Swarm Optimization (PSO) that is easy to fall into local optimum and Artificial Bee Colony (ABC) that has insufficient development ability, an Integrated Algorithm Based on ABC and PSO (IABAP) is established. Through eight different test functions and comparing with other different algorithms, it is verified that the IABAP algorithm has certain advantages in terms of convergence speed and accuracy. Considering the influence of ambient air temperature and multi-shift water cooling during construction, IABAP is applied to the inversion of concrete thermal parameters with the same strength, different strength and different gradation of Baihetan arch dam. The computational results show the good performance of the IABAP algorithm in engineering applications on the one hand, and the applicability and reliability of the parameter inversion on the other hand, which can meet the accuracy requirements of practical engineering. At the same time, the conjecture that the thermal parameters are consistent in adjacent dam sections was verified by bringing the thermal parameters into the adjacent dam sections for simulation calculations. Finally, the experimental values of thermal parameters of low-heat cement concrete of Baihetan Dam were compared with the inverse values to analyze the change law of thermal parameters, and it was found that the final adiabatic temperature rise of low-heat concrete was smaller than the indoor experimental values during the actual construction.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Physical Properties and Hydration Characteristics of Low-Heat Portland Cement at High-Altitude
    Wang, Ning
    Liu, Qiang
    Xia, Yanqing
    Li, Jun
    Lu, Zhongyuan
    Xu, Yigang
    Zhong, Wen
    Lin, Yan
    MATERIALS, 2023, 16 (08)
  • [42] Effect of low-heat cement Portland cement on alkali-silica reaction of aggregates with different alkali-reactivities
    Yang, Shuqing
    Feng, Wei
    Xu, Qing
    Cui, Hongzhi
    Poon, Chi Sun
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 447
  • [43] Formulating a low-alkalinity, high-resistance and low-heat concrete for radioactive waste repositories
    Coumes, Celine Cau Dit
    Courtois, Simone
    Nectoux, Didier
    Leclercq, Stephanie
    Bourbon, Xavier
    CEMENT AND CONCRETE RESEARCH, 2006, 36 (12) : 2152 - 2163
  • [44] Effect of gypsum on low-heat Portland cement early mechanical properties and hydration in the presence of DEIPA
    Yao, Guang
    Wan, Hao
    Tang, Guanbao
    Gao, Xianshu
    Zhang, Kunyue
    Huang, Wen
    Yu, Yang
    Shen, Xin
    Cui, Suping
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 449
  • [45] Macro-Mesoscale Mechanical Properties of Basalt-Polyvinyl Alcohol Hybrid Fiber-Reinforced Low-Heat Portland Cement Concrete
    Zhang, Yu
    Zheng, Yuanxun
    POLYMERS, 2023, 15 (03)
  • [46] Diffusion Behavior of Organic Carbon and Iodine in Low-Heat Portland Cement Containing Fly Ash
    Chida, Taiji
    Sugiyama, Daisuke
    SCIENTIFIC BASIS FOR NUCLEAR WASTE MANAGEMENT XXXII, 2009, 1124 : 379 - 384
  • [47] Effect of Particle Size of Periclase on the Periclase Hydration and Expansion of Low-Heat Portland Cement Pastes
    Yan, Man
    Deng, Min
    Wang, Chen
    Chen, Zhiyang
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [48] Optimized inversion method for thermal parameters of concrete dam under the insulated condition
    Bo, Chen
    Qingyi, Wang
    Weinan, Chen
    Hao, Gu
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 126
  • [49] Experimental study on fracture energy of low-heat concrete by three-point bend tets
    Jo, BW
    Tae, GH
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2001, 37 (12) : 907 - 915
  • [50] Elastic Strength Diagnosis of the Dez Concrete Arch Dam Using Thermal Inverse Analysis
    Labibzadeh, Mojtaba
    Khajehdezfuly, Amin
    Khayat, Majid
    Arab, Yaqub
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (06)