Biomechanical Analysis of Axial Gradient Porous Dental Implants: A Finite Element Analysis

被引:3
|
作者
Zhang, Chunyu [1 ,2 ,3 ]
Wang, Yuehong [1 ,2 ,3 ]
机构
[1] Cent South Univ, Xiangya Stomatol Hosp, 72 Xiangya St, Changsha 410008, Peoples R China
[2] Cent South Univ, Xiangya Sch Stomatol, 72 Xiangya St, Changsha 410008, Peoples R China
[3] Hunan 3D Printing Engn Res Ctr Oral Care, 64 Xiangya St, Changsha 410008, Peoples R China
关键词
gradient porous implants; finite element analysis; biomechanics; elasticity modulus; STRESS-DISTRIBUTION; TITANIUM IMPLANTS; BONE STRESS; DESIGN; OPTIMIZATION; SCAFFOLDS;
D O I
10.3390/jfb14120557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The porous structure can reduce the elastic modulus of a dental implant and better approximate the elastic characteristics of the material to the alveolar bone. Therefore, it has the potential to alleviate bone stress shielding around the implant. However, natural bone is heterogeneous, and, thus, introducing a porous structure may produce pathological bone stress. Herein, we designed a porous implant with axial gradient variation in porosity to alleviate stress shielding in the cancellous bone while controlling the peak stress value in the cortical bone margin region. The biomechanical distribution characteristics of axial gradient porous implants were studied using a finite element method. The analysis showed that a porous implant with an axial gradient variation in porosity ranging from 55% to 75% was the best structure. Under vertical and oblique loads, the proportion of the area with a stress value within the optimal stress interval at the bone-implant interface (BII) was 40.34% and 34.57%, respectively, which was 99% and 65% higher compared with that of the non-porous implant in the control group. Moreover, the maximum equivalent stress value in the implant with this pore parameter was 64.4 MPa, which was less than 1/7 of its theoretical yield strength. Axial gradient porous implants meet the strength requirements for bone implant applications. They can alleviate stress shielding in cancellous bone without increasing the stress concentration in the cortical bone margin, thereby optimizing the stress distribution pattern at the BII.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Finite Element Stress Analysis of Dental Prostheses Supported by Straight and Angled Implants
    Cruz, Mauro
    Wassall, Thomaz
    Toledo, Elson Magalhaes
    da Silva Barra, Luis Paulo
    Cruz, Silvia
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (03) : 391 - 403
  • [42] Evaluating parameters of osseointegrated dental implants using finite element analysis.
    Holmgren, EP
    Seckinger, RJ
    Kilgren, LM
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 245 - 245
  • [43] Finite Element Analysis of Zirconia Ceramic Biomaterials Used in Medical Dental Implants
    Sharanraj V.
    Ramesha C.M.
    Kumar V.
    Sadashiva M.
    InterCeram: International Ceramic Review, 2019, 68 (03): : 24 - 31
  • [44] BIOMECHANICAL EVALUATION OF MANDIBULAR OVERDENTURES SUPPORTED BY MINI-IMPLANTS: A FINITE ELEMENT ANALYSIS
    Ganesh, Thiagarajan
    Scully, Jessica
    Walker, Mary P.
    Petrie, Cynthia S.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (06)
  • [45] Biomechanical behavior of dental implants-photoelastic analysis
    Gomes, V. N.
    Tripak, D.
    Oliveira, S.
    Reis Campos, J. C.
    Figueiral, M. H.
    BIODENTAL ENGINEERING V, 2019, : 285 - 291
  • [46] Finite-element study of biomechanical explanations for bone loss around dental implants
    Merdji A.
    Taharou B.
    Hillstrom R.
    Benaissa A.
    Roy S.
    Chong P.L.
    Mukdadi O.
    Della N.
    Bouiadjra B.-A.B.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (01) : 21 - 30
  • [47] A 3D Nonlinear Finite Element Study on Biomechanical Behavior of Dental Implants
    Wu, Ting
    Liao, Wenhe
    Dai, Ning
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 3263 - 3267
  • [48] Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    Barbier, L
    Vander Sloten, J
    Krzesinski, G
    Schepers, E
    Van Der Perre, G
    JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) : 847 - 858
  • [49] STRESS ANALYSIS OF POROUS ROOTED DENTAL IMPLANTS
    WEINSTEIN, AM
    KLAWITTER, JJ
    ANAND, SC
    SCHUESSLER, R
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (05) : 772 - 777
  • [50] Biomechanical Fatigue Behavior of a Dental Implant Due to Chewing Forces: A Finite Element Analysis
    Martinez-Mondragon, Miguel
    Urriolagoitia-Sosa, Guillermo
    Romero-angeles, Beatriz
    Garcia-Laguna, Miguel Angel
    Laguna-Canales, Aldo Saul
    Perez-Partida, Juan Carlos
    Mireles-Hernandez, Jonatan
    Carrasco-Hernandez, Francisco
    Urriolagoitia-Calderon, Guillermo Manuel
    MATERIALS, 2024, 17 (07)