Improvement of the Treatment Performance of the Conventional Wastewater Treatment Plant: A Case Study of the Central Wastewater Treatment Plant in Ulaanbaatar, Mongolia

被引:0
|
作者
Nyamjav, Boldbaatar [1 ]
Badarch, Ayurzana [1 ]
Sangi, Chuluunkhuyag [2 ]
Khurelbaatar, Ganbaatar [3 ]
机构
[1] Mongolian Univ Sci & Technol, Sch Civil Engn & Architecture, Dept Engn Facil, Ulaanbaatar 14191, Mongolia
[2] Mongolian Univ Sci & Technol, Sch Civil Engn & Architecture, Dept Environm Engn, Ulaanbaatar 14191, Mongolia
[3] UFZ Helmholtz Ctr Environm Res, Ctr Environm Biotechnol, D-04318 Leipzig, Germany
关键词
wastewater; total suspended solids; biochemical oxygen demand; equalization tank; pre-aeration;
D O I
10.3390/su15054528
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study is carried out within the framework of the requirements of ensuring reliable operation of the Central Wastewater Treatment Plant of Ulaanbaatar to increase the treatment performance and mitigate the adverse impacts of the current poor performance on nature and ecology. The dynamic of the current influent was studied in order to find the best-suited solution as a means of improvement for the WWTP. As an immediate and fast-to-build solution, an equalization tank and pre-aeration facilities were proposed. The positive effect of the facilities on the biological treatment stage and the overall treatment performance was estimated both theoretically and empirically. The results showed that the overall performance of the treatment for BOD5 and TSS will be increased by up to 30% and 10%, respectively. Furthermore, the high fluctuation problems the central WWTP in terms of hydraulic and pollution load will be positively affected by the intervention, eliminating the main cause of the current poor treatment performance.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Performance analysis of a denitrifying wastewater treatment plant
    Miguel Mussati
    Krist Gernaey
    Rafiqul Gani
    Sten Jørgensen
    Clean Technologies and Environmental Policy, 2002, 4 (3) : 171 - 182
  • [22] Environmental performance of a municipal wastewater treatment plant
    Hospido, A
    Moreira, MT
    Fernández-Couto, M
    Feijoo, G
    INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2004, 9 (04): : 261 - 271
  • [23] Performance evaluation of the main units of a refinery wastewater treatment plant - A case study
    Santos, Carlos E.
    Fonseca, Andre
    Kumar, Eva
    Bhatnagar, Amit
    Vilar, Vitor J. P.
    Botelho, Cidalia M. S.
    Boaventura, Rui A. R.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2015, 3 (03) : 2095 - 2103
  • [24] A typical case study of the operational performance of municipal wastewater treatment plant in China
    Zhang, Xiaoxin
    Huang, Jin
    Lin, Ling
    Liu, Shuming
    Wang, Yueping
    Zhang, Sinan
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2020, 15 (S1)
  • [25] Impact of Climate Change on the Performance of Wastewater Treatment Plant: Case study Central Irbid WWTP (Jordan)
    Abdulla, Fayez
    Farahat, Saif
    1ST INTERNATIONAL CONFERENCE ON OPTIMIZATION-DRIVEN ARCHITECTURAL DESIGN (OPTARCH 2019), 2020, 44 : 205 - 212
  • [26] SOLUTIONS FOR ENERGY EFFICIENCY IMPROVEMENT IN WASTEWATER TREATMENT PLANT
    Cruceru, Mihai
    Diaconu, Bogdan
    Popescu, Luminita Georgeta
    Anghelescu, Lucica
    ENERGY AND CLEAN TECHNOLOGIES CONFERENCE PROCEEDINGS, SGEM 2016, VOL I, 2016, : 647 - 652
  • [27] Performance of direct filtration with multi-media filters for reuse of wastewater treatment plant effluent: a case study. Baharan industrial wastewater treatment plant
    Seidmohammadi, Abdolmotaleb
    Asgari, Ghorban
    Rahmani, Alireza
    Ghelichi, Faezeh
    DESALINATION AND WATER TREATMENT, 2021, 229 : 31 - 39
  • [28] The Distribution of Microalgae in a Stabilization Pond System of a Domestic Wastewater Treatment Plant in a Tropical Environment (Case Study: Bojongsoang Wastewater Treatment Plant)
    Ariesyady, Herto Dwi
    Fadilah, Rifka
    Kurniasih
    Sulaeman, Aminudin
    Kardena, Edwan
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2016, 48 (01): : 86 - 98
  • [29] Simulation of a transient failure in a wastewater treatment plant: A case study
    Rouleau, S
    Lessard, P
    Bellefleur, D
    WATER SCIENCE AND TECHNOLOGY, 1997, 36 (05) : 349 - 355
  • [30] Effect of FeCl3 concentration in chemically enhanced primary treatment on the performance of a conventional wastewater treatment plant. A case study
    Ruiz, L. M.
    Checa, A.
    Perez, J. I.
    Torre-Marin, J. M.
    Munoz-Ubina, A.
    Gomez, M. A.