A new method for determining the effective length factor of columns in partially braced frames on elastic supports

被引:2
|
作者
Slimani, Adel [1 ]
Belaid, Toufik [1 ]
Saidani, Messaou [2 ]
Ammari, Fatiha [1 ]
Adman, Redouane [1 ]
机构
[1] Univ Sci & Technol Houari Boumediene USTHB, Fac Civil Engn, Built Environm Res Lab, BP 32 El Alia, Algiers 16111, Algeria
[2] Coventry Univ, Inst Clean Growth & Future Mobil, Friars House, Coventry CV1 2TE, England
关键词
critical load; effective length factor; elastic buckling; instability; stability functions; K-FACTOR; MULTISTORY FRAMES; BUCKLING LENGTHS; SEMIRIGID JOINTS; STABILITY; SWAY; LOAD;
D O I
10.12989/sem.2023.85.6.825
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effective buckling length factor is an important parameter in the elastic buckling analysis of steel structures. The present article aims at developing a new method that allows the determination of the buckling factor values for frames. The novelty of the method is that it considers the interaction between the bracing and the elastic supports for asymmetrical frames in particular. The approach consists in isolating a critical column within the frame and evaluating the rotational and translational stiffness of its restraints to obtain the critical buckling load. This can be achieved by introducing, through a dimensionless parameter phi(i), the effects of coupling between the axial loading and bending stiffness of the columns, on the classical stability functions. Subsequently, comparative, and parametric studies conducted on several frames are presented for assessing the influence of geometry, loading, bracing, and support conditions of the frame columns on the value of the effective buckling length factor K. The results show that the formulas recommended by different approaches can give rather inaccurate values of K, especially in the case of asymmetric frames. The expressions used refer solely to local stiffness distributions, and not to the overall behavior of the structure.
引用
收藏
页码:825 / 835
页数:11
相关论文
共 50 条
  • [11] EVALUATION OF EFFECTIVE LENGTH FACTORS IN BRACED FRAMES
    FRASER, DJ
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1983, 10 (01) : 18 - 26
  • [12] Effective length factor of columns in semirigid and unbraced frames - Discussion
    Essa, HS
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10): : 1230 - 1231
  • [13] The effective length factor of columns in unsymmetrical frames asymmetrically loaded
    Slimani A.
    Ammari F.
    Adman R.
    Asian Journal of Civil Engineering, 2018, 19 (4) : 487 - 499
  • [14] NEW STABILITY EQUATION FOR COLUMNS IN BRACED FRAMES
    GONCALVES, R
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (07): : 1853 - 1870
  • [15] Fuzzy logic based estimation of effective lengths of columns in partially braced multi-storey frames
    Menon, D
    STRUCTURAL ENGINEERING AND MECHANICS, 2001, 11 (03) : 287 - 299
  • [16] EFFECTIVE LENGTH OF COLUMNS IN UNBRACED FRAMES
    GOGATE, AB
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1971, 8 (03): : 110 - &
  • [17] EFFECTIVE LENGTH OF COLUMNS IN UNBRACED FRAMES
    YURA, JA
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1971, 8 (02): : 37 - &
  • [18] Effective Lengths of Columns in Braced Multi-Storey Frames
    Girgin, Konuralp
    Ozmen, Guenay
    TEKNIK DERGI, 2008, 19 (01): : 4333 - 4346
  • [19] Effective lengths of columns in braced multi-storey frames
    Istanbul Technical University, Istanbul, Turkey
    不详
    Teknik Dergi/Technical Journal of Turkish Chamber of Civil Engineers, 2008, 19 (SPEC. ISS.): : 1203 - 1216
  • [20] Effective length factor of columns in sway and semi-rigid composite frames
    Wang, Jing-Feng
    Li, Guo-Qiang
    Gongcheng Lixue/Engineering Mechanics, 2007, 24 (03): : 71 - 77