Non-destructive operando measurements of muonic x-rays on Li-ion battery

被引:1
|
作者
Umegaki, I. [1 ,2 ,3 ]
Kondo, Y. [3 ]
Tampo, M. [1 ,2 ]
Nishimura, S. [1 ,2 ]
Takeshita, S. [1 ,2 ]
Higuchi, Y. [3 ]
Kondo, H. [3 ]
Sasaki, T. [3 ]
Shimomura, K. [1 ,2 ]
Miyake, Y. [1 ,2 ]
机构
[1] IMSS, Muon Sci Div, High Energy Accelerator Res Org KEK, Tokai, Ibaraki 3191106, Japan
[2] J PARC Ctr, Mat & Life Sci Div, Muon Sci Sect, Tokai, Ibaraki 3191195, Japan
[3] Toyota Cent Res Dev Lab Inc, Yokomichi 41-1, Nagakute, Aichi 4801192, Japan
来源
15TH INTERNATIONAL CONFERENCE ON MUON SPIN ROTATION, RELAXATION AND RESONANCE | 2023年 / 2462卷
关键词
D O I
10.1088/1742-6596/2462/1/012018
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have developed a non-destructive technique to observe Li in an electrode and metallic Li deposition on an anode using muonic x-rays. With high intent negative muon beam at J-PARC, we have attempted operando measurements of Li and metallic Li deposition in LIBs for the first time. Both increase and decrease of Li in a cathode during charging and discharging processes were observed. We also observed significant increase of muonic x-rays of Li with cycles, which may correspond to the degradation of charge capacity with the cycles.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Non-destructive elemental depth-profiling with muonic X-rays
    Kubo, M. K.
    Moriyama, H.
    Tsuruoka, Y.
    Sakamoto, S.
    Koseto, E.
    Saito, T.
    Nishiyama, K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 777 - 781
  • [2] Non-destructive elemental depth-profiling with muonic X-rays
    M. K. Kubo
    H. Moriyama
    Y. Tsuruoka
    S. Sakamoto
    E. Koseto
    T. Saito
    K. Nishiyama
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 777 - 781
  • [3] Non-destructive elemental analysis of vertebral body trabecular bone using muonic X-rays
    Hosoi, Y
    Watanabe, Y
    Sugita, R
    Tanaka, Y
    Nagamine, K
    Ono, T
    Sakamoto, K
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (816): : 1325 - 1331
  • [4] Application of Analysis with Muonic X-rays for Battery
    Umegaki, Izumi
    Kondo, Yasuhito
    Higuchi, Yuki
    JOURNAL OF COMPUTER CHEMISTRY-JAPAN, 2020, 19 (03) : 99 - 105
  • [5] A NON-DESTRUCTIVE CORE ANALYSIS TECHNIQUE USING X-RAYS
    BAKER, SR
    FRIEDMAN, GM
    JOURNAL OF SEDIMENTARY PETROLOGY, 1969, 39 (04): : 1371 - &
  • [6] Spectroscopic Measurements of L X-rays with a TES Microcalorimeter for a Non-destructive Assay of Transuranium Elements
    Nakamura, Keisuke
    Morishita, Yuki
    Takasaki, Koji
    Maehata, Keisuke
    Sugimoto, Tetsuya
    Kiguchi, Yu
    Iyomoto, Naoko
    Mitsuda, Kazuhisa
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (3-4) : 314 - 320
  • [7] Spectroscopic Measurements of L X-rays with a TES Microcalorimeter for a Non-destructive Assay of Transuranium Elements
    Keisuke Nakamura
    Yuki Morishita
    Koji Takasaki
    Keisuke Maehata
    Tetsuya Sugimoto
    Yu Kiguchi
    Naoko Iyomoto
    Kazuhisa Mitsuda
    Journal of Low Temperature Physics, 2018, 193 : 314 - 320
  • [8] Non-destructive quality determination of pecans using soft X-rays
    Kotwaliwale, Nachiket
    Weckler, Paul R.
    Brusewitz, Glenn H.
    Kranzler, Glenn A.
    Maness, Niels O.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2007, 45 (03) : 372 - 380
  • [9] A non-destructive view with X-rays into the strain state of bronze axes
    Glaser, L.
    Rothkirch, A.
    Techert, S.
    Freudenberg, M.
    MICROCHEMICAL JOURNAL, 2016, 126 : 322 - 325
  • [10] A compact imaging system with a CdTe double-sided strip detector for non-destructive analysis using negative muonic X-rays
    Katsuragawa, Miho
    Tampo, Motonobu
    Hamada, Koji
    Harayama, Atsushi
    Miyake, Yasuhiro
    Oshita, Sayuri
    Sato, Goro
    Takahashi, Tadayuki
    Takeda, Shin'ichiro
    Watanabe, Shin
    Yabu, Goro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 140 - 143