Two- and Four-Electrode Configurations for Contactless Reinforced Concrete Corrosion Monitoring

被引:2
|
作者
Diaz, B. [1 ]
Novoa, X. R. [1 ]
Perez, C. [1 ]
Pintos, A. [1 ]
Vivier, V. [2 ]
机构
[1] Univ Vigo, CINTECX, EEI, ENCOMAT Grp, Vigo 36310, Spain
[2] Sorbonne Univ, CNRS, Lab React Surface, Paris, France
关键词
contactless method; corrosion rate determination; impedance spectroscopy; steel in concrete; NONINVASIVE SURFACE MEASUREMENT; STEEL-BAR CORROSION; IMPEDANCE;
D O I
10.5006/4200
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper addresses the need for a fast and reliable method for field monitoring reinforced concrete structures. A proof of concept is presented where a noncontact procedure provides quantitative information on the concrete resistivity and reinforcement corrosion rate. A Wenner-type probe is presented, where a combination of two- and four-electrode measurements in a relatively high-frequency domain allows obtaining the information of interest. The method is based on the fact, verified by numerical simulations, that the embedded rebar works as an effective floating counter electrode and, thus, for distances higher than a critical value (1 cm in the simulations done), the ratio of concrete resistivity to the measured impedance at 1 kHz is constant and only dependent on the electrode diameter. The apparent polarization resistance measured with the four-electrode arrangement and normalized to the concrete resistivity allows obtaining the actual polarization resistance without contacting the rebar whose distance to the electrodes shall be known.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 50 条
  • [21] Wireless sensors for monitoring corrosion in reinforced concrete members
    Simonen, JT
    Andringa, MM
    Grizzle, KM
    Wood, SL
    Neikirk, DP
    SMART STRUCTURES AND MATERIALS 2004: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS, 2004, 5391 : 587 - 596
  • [22] Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures
    Verma, Sanjeev Kumar
    Bhadauria, Sudhir Singh
    Akhtar, Saleem
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [23] Corrosion monitoring system for a reinforced concrete transit tunnel
    Galimberti, P
    Gaddi, F
    Alberizzi, M
    Lazzari, L
    MATERIALS PERFORMANCE, 1999, 38 (03) : 26 - 31
  • [24] Monitoring and Accelerating Methods of Corrosion for Reinforced Concrete: A Review
    Nayak, Chittaranjan
    Disale, Anil
    Suryawanshi, Nagesh
    Jadhav, Nitin
    Jagdale, Umesh
    Bhoite, Gauri
    Thakare, Sunil
    Pandey, Shri Prakash
    MACROMOLECULAR SYMPOSIA, 2024, 413 (01)
  • [25] Advances of monitoring corrosion in reinforced concrete based on UGW
    Zheng, Zhupeng
    DEVELOPMENT OF INDUSTRIAL MANUFACTURING, 2014, 525 : 499 - 503
  • [26] Remote monitoring of corrosion potentials in reinforced concrete bridges
    Calderon, F. Almeraya
    Tiburcio, C. Gaona
    Borunda, A.
    Carmona, V. Orozco
    Olvera, G. Vazquez
    Villafane, A. Martinez
    Gonzalez, Jose Castorena
    Avila, J. Castaneda
    Flores, J. C. Huerta
    MATERIALS PERFORMANCE, 2006, 45 (11) : 20 - 24
  • [27] Kelvin Probe electrode for contactless potential measurement on concrete - Properties and corrosion profiling application
    Saguees, Alberto A.
    Walsh, Michael T.
    CORROSION SCIENCE, 2012, 56 : 26 - 35
  • [28] Studies on corrosion monitoring of reinforced concrete in a chloride environment using an embedded solid-state reference electrode
    Subbiah, Karthick
    Lee, Han-Seung
    Park, Taejoon
    Annamalai, Sivasankar
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 364
  • [29] Screen-printed electrode as a cost-effective and miniaturized analytical tool for corrosion monitoring of reinforced concrete
    Sassolini, Alessandro
    Colozza, Noemi
    Papa, Elena
    Hermansson, Kersti
    Cacciotti, Ilaria
    Arduini, Fabiana
    ELECTROCHEMISTRY COMMUNICATIONS, 2019, 98 : 69 - 72
  • [30] Non-destructive reinforced concrete corrosion monitoring techniques
    Bjegovic, D
    Mikulic, D
    Sekulic, D
    PREVIOUS EXPERIENCE AND CURRENT INNOVATIONS IN NON-DESTRUCTIVE TESTING, 2001, : 265 - 274