Characterization of SiN/SiO2-based MEMS-VCSEL at 1550 nm for Optical Coherence Tomography

被引:0
|
作者
Lamoso, I. Rodriguez [1 ]
Jimenez, A. Martinez [2 ]
Cesar, J. [1 ]
Preu, S. [1 ]
Podoleanu, A. [2 ]
机构
[1] Tech Univ Darmstadt, Inst Microwave Engn & Photon, Darmstadt, Germany
[2] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
基金
欧盟地平线“2020”;
关键词
Swept source Optical Coherent Tomography; Microelectromechanical Movable Mirror Vertical Cavity Emission Laser; channelled spectrum; Complex Master Slave;
D O I
10.1117/12.2652961
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Due to its superior imaging performance Swept Source Optical Coherent Tomography (SS-OCT) has become an established 3D imaging methodology. One of the key elements of this technique is the swept source as its tuning range and tuning speed will define the axial resolution and the time required to acquire an A-scan. This work presents the characterization of the performance in SS-OCT of an electrically pumped Microelectromechanical Movable Mirror Vertical Cavity Surface Emitting Laser (MEMS-VCSEL) in the range from 1540-1600nm. To investigate the tuning performance of the MEMS-VCSEL its output signal is amplified with and Erbium doped (Er+) fiber amplifier connected to an OCT system where the channelled spectrum is processed by using a Complex Master Slave (CMS) method that evaluates the nonlinearity in tuning in both forwards and backwards tuning for tuning frequencies of 10, 50 and 100 Hz. The results obtained show that the linearity of the device increases as the tuning frequency does and it has a sensitivity roll-off at 6dB of 12.65 mm which is equivalent to an instantaneous linewidth of 85pm.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Wettability characterization method based on optical coherence tomography imaging
    Fabritius, Tapio
    Myllyla, Risto
    Makita, Shuichi
    Yasuno, Yoshiaki
    OPTICS EXPRESS, 2010, 18 (22): : 22859 - 22866
  • [32] Characterization of Cell Distribution Based on Optical Coherence Tomography Scattering
    Shen R.
    Wang L.
    Xu M.
    Peng S.
    Wang, Ling (lingw@hdu.edu.cn), 2020, Science Press (47):
  • [33] A Miniaturized Electrothermal-MEMS-Based Optical Coherence Tomography (OCT) Handheld Microscope
    Chen, Qian
    Zhao, Hui
    Qi, Tingxiang
    Wang, Hua
    Xie, Huikai
    PHOTONICS, 2024, 11 (01)
  • [34] Design Optimization and Implementation of a Miniature Optical Coherence Tomography Probe Based on a MEMS Mirror
    Wang, Donglin
    Fu, Linlai
    Sun, Jingjing
    Jia, Hongzhi
    Xie, Huikai
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: SENSOR AND MICROMACHINED OPTICAL DEVICE TECHNOLOGIES, 2011, 8191
  • [35] Compact MEMS-based adaptive optics: Optical coherence tomography for clinical use
    Chen, Diana C.
    Olivier, Scot S.
    Jones, Stever M.
    Zawadzki, Robert J.
    Evans, Julie W.
    Choi, Stacey S.
    Werner, John S.
    MEMS ADAPTIVE OPTICS II, 2008, 6888
  • [36] Handheld MEMS-based Optical Coherence Tomography in Anterior and Posterior Segment Diagnosis
    Sayegh, Samir
    Taibl, Jessica
    Jung, Woongyu
    McCormick, Daniel
    Shelton, Ryan
    Nolan, Ryan
    Boppart, Stephen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [37] MEMS based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography
    Xu, Yingshun
    Singh, Janak
    Jason, Teo Hui Siang
    Ramakrishna, Kotlanka
    Premchandran, C. S.
    Kelvin, Chen Wei Sheng
    Kuan, Chuah Tong
    Chen, Nanguang
    Olivo, Malini C.
    Sheppard, Colin J. R.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES III, 2007, 6627
  • [38] Synthesis and characterization of SiO2-based porous glass membranes for CO2 separation
    Park, JJ
    Kawai, C
    Nakahata, S
    Yamagiwa, M
    Nishioka, T
    Takeuchi, H
    Yamakawa, A
    INNOVATIVE PROCESSING AND SYNTHESIS OF CERAMICS, GLASSES, AND COMPOSITES II, 1999, 94 : 337 - 346
  • [39] Growth, characterization and the limits of ultrathin SiO2-based dielectrics for future CMOS applications
    Buchanan, DA
    Lo, SH
    PHYSICS AND CHEMISTRY OF SIO(2) AND THE SI-SIO(2) INTERFACE-3, 1996, 1996, 96 (01): : 3 - 14
  • [40] Optical alignment of dual-axis MEMS based scanning optical probe for Optical Coherence Tomography (OCT) application
    Khairyanto, Ahmad
    Premachandran, C. S.
    Chen, Kelvin W. S.
    Singh, Janak
    Chandrappan, Jayakrishnan
    Lau, John H.
    Xu, Yingshun
    EPTC: 2008 10TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, VOLS 1-3, 2008, : 945 - 950