Deep inspiratory breath hold assisted by continuous positive airway pressure ventilation for lung stereotactic body radiotherapy

被引:3
|
作者
Appel, S. [1 ,2 ]
Lawrence, Y. R. [1 ,2 ]
Bar, J. [2 ,3 ]
Jacobson, G. [1 ,2 ]
Marom, E. M. [2 ,4 ]
Katzman, T. [1 ,2 ]
Ben-Ayun, M. [1 ,2 ]
Dubinski, S. [1 ,2 ]
Haisraely, O. [1 ,2 ]
Weizman, N. [5 ]
Davidson, T. [6 ]
Weiss, I. [1 ,2 ]
Mansano, A. [1 ,2 ]
Goldstein, J. D. [7 ]
Symon, Z. [1 ,2 ]
机构
[1] Sheba Med Ctr, Dept Radiat Oncol, Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Inst Oncol, Tel Hashomer, Israel
[4] Sheba Med Ctr, Dept Radiol, Tel Hashomer, Israel
[5] Hadassah Med Ctr, Dept Radiat Oncol, Jerusalem, Israel
[6] Sheba Med Ctr, Nucl Med, Tel Hashomer, Israel
[7] Ichilov Hosp, Dept Radiat Oncol, Tel Aviv, Israel
来源
CANCER RADIOTHERAPIE | 2023年 / 27卷 / 01期
关键词
CONE-BEAM CT; RADIATION-THERAPY SBRT; MOTION MANAGEMENT; EARLY-STAGE; ABLATIVE RADIOTHERAPY; RESPIRATORY MOTION; TUMORS; CANCER; IMMOBILIZATION; IMPACT;
D O I
10.1016/j.canrad.2022.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Continuous positive airway pressure (CPAP) ventilation hyperinflates the lungs and reduces diaphragmatic motion. We hypothesized that CPAP could be safely combined with deep inspiratory breath hold (CPAP-DIBH) during lung stereotactic radiotherapy (SBRT). Material and methods. - Patients with stage-1 lung cancer or lung metastasis treated with CPAP-DIBH SBRT between 3/20175/2021 were analyzed retrospectively. Patient characteristics, treatment parameters, duration of breath holds in all sessions and tolerance to CPAP-DIBH were recorded. Local control (LC) was assessed from CT or PET-CT imaging. The distances between the tumor and mediastinal organs at risk (OAR) in centrally located tumors using either free breathing (FB) or CPAP-DIBH were compared. Toxicity was graded retrospectively. Results. - Forty-five patients with 71 lesions were treated with CPAP-DIBH SBRT. Indications for CPAP-DIBH were prior radiation (35/71, 65%), lower lobe location (34/71, 48%), multiple lesions (26/71, 36.6%) and proximity to mediastinal OAR (7/71, 10%). Patient characteristics were: F:M 43%: 57%; mean gross tumor volume 4.5 cm3 (SD 7.9), mean planning target volume 20 cm3 (SD 27), primary: metastatic lesions (7%:93%). Mean radiation dose was 52.5 Gray (SD3.5). Mean lung volume was 5292 cm3 (SD 1106). Mean duration of CPAP-DIBH was 41.3 s (IQR 3146.8). LC at 2 years was 89.5% (95% CI 7695.5). In patients with central lesions, the distance between the tumor and mediastinal OAR increased from 0.84 cm (SD 0.65) with FB to 1.23 cm (SD 0.8) with CPAP-DIBH (p = 0.002). Most patients tolerated CPAP well and completed all treatments after starting therapy. Three patients did not receive treatment: 2 were unable to tolerate CPAP and 1 had syncope (pre-existing). Toxicity was grade 2 in 4/65 (6%) and grade 3 in 1/65 (1.5%). There was no grade 2 or higher esophageal or tracheal toxicities. Conclusion. - CPAP-DIBH assisted lung SBRT was tolerated well and was associated with minimal toxicity and favorable LC. This technique may be considered when treating multiple lung lesions, lesions located in the lower lobes or adjacent to mediastinal OAR. (c) 2022 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [1] Dosimetric evaluation of continuous positive airway pressure with deep inspiratory breath hold for left sided breast cancer
    Singh, P.
    ANNALS OF ONCOLOGY, 2022, 33 : S182 - S182
  • [2] Lung Stereotactic Body Radiation Using Deep Inspiratory Breath Hold: A Dosimetric Evaluation of Targeting and Safety
    Waxer, J. F.
    Kim, F. S. H.
    Kim, D. W.
    Alfaro, A.
    Rahimian, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E359 - E360
  • [3] Characteristics of Tumor Motions with Deep Inspiration Breath Hold for Lung Stereotactic Body Radiotherapy Patients
    Zhao, G.
    Jayarathna, S. Y.
    Peeler, C. R.
    Pollard-Larkin, J. M.
    Sadagopan, R.
    Nitsch, P. L.
    Ohrt, J. D.
    Gao, S.
    Balter, P.
    Wang, X.
    MEDICAL PHYSICS, 2024, 51 (10) : 7861 - 7862
  • [4] CARDIORESPIRATORY EFFECTS OF AN INSPIRATORY HOLD AND CONTINUOUS POSITIVE PRESSURE VENTILATION IN GOATS
    PEREZCHADA, RD
    GARDAZ, JP
    MADGWICK, RG
    SYKES, MK
    INTENSIVE CARE MEDICINE, 1983, 9 (05) : 263 - 269
  • [5] CARDIORESPIRATORY EFFECTS OF AN INSPIRATORY HOLD AND CONTINUOUS POSITIVE PRESSURE VENTILATION IN GOATS
    PEREZCHADA, RD
    GARDAZ, JP
    MADGWICK, RG
    SYKES, MK
    BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (07) : P783 - P783
  • [6] Early Experiences of Deep Inspiration Breath Hold Technique in Stereotactic Body Radiotherapy for Localized Lung Tumor
    Mani, K. R.
    Sumon, M. A.
    Chaudhuri, S.
    Nabi, R.
    Sengupta, A. K.
    Ahmed, S.
    Uddin, A. Kamal
    Bhuiyan, M. A.
    Haque, K. A.
    Lingaiah, R.
    Ahmed, S. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E330 - E330
  • [7] Dosimetric Impact of Deep Inspiration Breath Hold Uncertainty on Pancreas Stereotactic Body Radiotherapy
    Han-Oh, S.
    Hill, C.
    Wang, K. K. H.
    Ding, K.
    Li, H.
    Chen, H.
    Meyer, J. J.
    Narang, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E373 - E374
  • [8] Investigating Stability and Reproducibility of Deep Inspiration Breath Hold for Liver Stereotactic Body Radiotherapy
    Parsons, D.
    Iqbal, Z.
    Sanford, N. N.
    Reynolds, R.
    Stojadinovic, S.
    Aguilera, T. A.
    Chiu, T.
    Lu, W.
    Folkert, M. R.
    Gu, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E632 - E632
  • [9] Continuous positive airway pressure with deep inspiration breath hold in left-sided breast radiation therapy
    Reckhow, Jensen
    Kaidar-Person, Orit
    Ben-David, Merav A.
    Ostrovski, Anna
    Ilinsky, Dina
    Goldstein, Jeffrey
    Symon, Zvi
    Galper, Shira
    MEDICAL DOSIMETRY, 2021, 46 (02) : 127 - 131
  • [10] Application and dosimetric comparison of surface-guided deep inspiration breath-hold for lung stereotactic body radiotherapy
    Wang, Jiaxin
    Dong, Tingting
    Meng, Xiangyin
    Li, Wenbo
    Li, Nan
    Wang, Yijun
    Yang, Bo
    Qiu, Jie
    MEDICAL DOSIMETRY, 2024, 49 (04) : 372 - 379