Applied Research Note: Microbial composition of the biofilm of poultry drinking water system

被引:1
|
作者
Ogundipe, T. T. [1 ]
Beitia, S. [1 ]
Obe, T. [1 ]
机构
[1] Univ Arkansas, Dept Poultry Sci, Fayetteville, AR 72701 USA
来源
JOURNAL OF APPLIED POULTRY RESEARCH | 2024年 / 33卷 / 02期
关键词
poultry drinking water system (DWS); biofilm; broiler; microbial population; water quality;
D O I
10.1016/j.japr.2024.100403
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Ensuring good water quality is one of the key management strategies to promote optimal broiler health and performance. A few studies have assessed the microbial status of drinking water for poultry, but there is insufficient information on biofilm in the drinking water lines within the poultry housing facilities. The buildup of microbes in the drinking water system could potentially result in biofilm formation which eventually deteriorates water quality. Hence, in this preliminary study, we sought to evaluate biofilm formation in the drinking water lines of selected broiler houses and characterize their microbial composition. Three random houses in each of 5 farms were visited representing 15 total houses used in this study. Using a borescope, we confirmed the presence of biofilm in 4 water lines per house on each farm, and a sterile gauze swab was used to collect the biofilm from these water lines. All biofilm samples were analyzed for the total aerobic plate count (APC), presence of yeasts and molds (YM), and Enterobacteriaceae (EB). The data were analyzed with ANOVA, and means were separated with Tukey's HSD test at P <= 0.05 using JMP software. All 15 houses evaluated had aerobic bacteria population and YM, whereas 7 out of the 15 houses had EB counts. For APC, there were significant differences across the farms (P < 0.0001) with Farm 1 having the highest APC (3.65 Log(10) CFU/mL) and Farm 5 having the lowest APC (2.05 Log(10) CFU/mL). For YM, significant differences existed across farms (P < 0.0001), Farm 2 had the highest counts (4.44 Log(10) CFU/mL), whereas Farm 5 had the lowest count (1.19 Log(10) CFU/mL). EB was detected in 3 out of the 5 farms and the counts were not statistically different (P = 0.07). Based on a sample size of 15 commercial broiler houses, these results suggest the need to evaluate water lines for biofilm and develop effective mitigations.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Pyrosequencing Analysis of Bacterial Biofilm Communities in Water Meters of a Drinking Water Distribution System
    Hong, Pei-Ying
    Hwang, Chiachi
    Ling, Fangqiong
    Andersen, Gary L.
    LeChevallier, Mark W.
    Liu, Wen-Tso
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2010, 76 (16) : 5631 - 5635
  • [32] Biofilm formation and chlorine resistance of microbial communities in household drinking water system: Preliminary idea of using bacteria to control bacteria
    Shan, Lili
    Bao, Xiajun
    Xu, Siyang
    Zhu, Zebing
    Pei, Yunyan
    Zheng, Wanjun
    Yuan, Yixing
    PROCESS BIOCHEMISTRY, 2024, 141 : 179 - 189
  • [33] Distribution of microbial activity and specific microorganisms across sediment size fractions and pipe wall biofilm in a drinking water distribution system
    van der Wielen, Paul W. J. J.
    Lut, Maarten C.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2016, 16 (04): : 896 - 904
  • [34] Temporal Variations in the Abundance and Composition of Biofilm Communities Colonizing Drinking Water Distribution Pipes
    Kelly, John J.
    Minalt, Nicole
    Culotti, Alessandro
    Pryor, Marsha
    Packman, Aaron
    PLOS ONE, 2014, 9 (05):
  • [35] Microbial characteristics of a distribution system fed with nanofiltered drinking water
    Sibille, I
    Mathieu, L
    Paquin, JL
    Gatel, D
    Block, JC
    WATER RESEARCH, 1997, 31 (09) : 2318 - 2326
  • [36] Microbial diversity and composition of the sediment in the drinking water reservoir Saidenbach (Saxonia, Germany)
    Roeske, Kerstin
    Sachse, Rene
    Scheerer, Carola
    Roeske, Isolde
    SYSTEMATIC AND APPLIED MICROBIOLOGY, 2012, 35 (01) : 35 - 44
  • [37] Microbial Diversity and their Biofilm Formation Potential in Pipes of Water Distribution System
    Kaur, Rajanbir
    Kaur, Rajinder
    ASIAN JOURNAL OF WATER ENVIRONMENT AND POLLUTION, 2020, 17 (04) : 113 - 117
  • [38] Helicobacter sp recovered from drinking water biofilm sampled from a water distribution system
    Park, SR
    Mackay, WG
    Reid, DC
    WATER RESEARCH, 2001, 35 (06) : 1624 - 1626
  • [39] Characteristics of biofilm bacteria from tapping points of the drinking water distribution system
    Biedron, Izabela
    Traczewska, Teodora M.
    Plaza, Grazyna
    ROCZNIK OCHRONA SRODOWISKA, 2016, 18 : 86 - 99
  • [40] Effect of biofilm on cast iron pipe corrosion in drinking water distribution system: Corrosion scales characterization and microbial community structure investigation
    Teng, F.
    Guan, Y. T.
    Zhu, W. P.
    CORROSION SCIENCE, 2008, 50 (10) : 2816 - 2823