Degradation prediction of proton exchange membrane fuel cell stack using semi-empirical and data-driven methods

被引:40
|
作者
Wang, Yupeng [1 ,2 ]
Wu, Kangcheng [1 ]
Zhao, Honghui [2 ]
Li, Jincheng [2 ]
Sheng, Xia [2 ]
Yin, Yan [1 ]
Du, Qing [1 ]
Zu, Bingfeng [3 ]
Han, Linghai [2 ]
Jiao, Kui [1 ]
机构
[1] Tianjin Univ, State Key Lab Engines, 135 Yaguan Rd, Tianjin 300350, Peoples R China
[2] FAW, Gen R&D Inst, Powertrain Dept, 1 Xinhongqi St, Changchun 130013, Jilin, Peoples R China
[3] Tianjin Univ, Internal Combust Engine Res Inst, 92 Weijin Rd, Tianjin 300072, Peoples R China
关键词
Proton exchange membrane fuel cell system; Data-driven method; Semi-empirical equation; Degradation experiments; HYDROGEN; MODEL; DIFFUSION; LIFETIME; NETWORK;
D O I
10.1016/j.egyai.2022.100205
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Degradation prediction of proton exchange membrane fuel cell (PEMFC) stack is of great significance for improving the rest useful life. In this study, a PEMFC system including a stack of 300 cells and subsystems has been tested under semi-steady operations for about 931 h. Then, two different models are respectively established based on semi-empirical method and data-driven method to investigate the degradation of stack performance. It is found that the root mean square error (RMSE) of the semi-empirical model in predicting the stack voltage is around 1.0 V, while the predicted voltage has no local dynamic characteristics, which can only reflect the overall degradation trend of stack performance. The RMSE of short-term voltage degradation predicted by the DDM can be less than 1.0 V, and the predicted voltage has accurate local variation characteristics. However, for the long-term prediction, the error will accumulate with the iterations and the deviation of the predicted voltage begins to fluctuate gradually, and the RMSE for the long-term predictions can increase to 1.63 V. Based on the above characteristics of the two models, a hybrid prediction model is further developed. The prediction results of the semi-empirical model are used to modify the input of the data-driven model, which can effectively improve the oscillation of prediction results of the data-driven model during the long-term degradation. It is found that the hybrid model has good error distribution (RSEM = 0.8144 V, R2 = 0.8258) and local performance dynamic characteristics which can be used to predict the process of long-term stack performance degradation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A transient semi-empirical voltage model of a fuel cell stack
    Hou, Yongping
    Zhuang, Mingxi
    Wan, Gang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (07) : 857 - 862
  • [22] Comparative study of a new semi-empirical model of the proton exchange membrane fuel cell for online prognostics applications
    Perez, L. M.
    Jemei, Samir
    Boulon, Loic
    Ravey, Alexandre
    Kandidayeni, Mohsen
    Solano, Javier
    ENERGY CONVERSION AND MANAGEMENT, 2025, 331
  • [23] Development of a one-dimensional and semi-empirical model for a high temperature proton exchange membrane fuel cell
    Nalbant, Yagmur
    Colpan, C. Ozgur
    Devrim, Yilser
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (11) : 5939 - 5950
  • [24] AI-assisted proton exchange membrane (PEM) fuel cell performance prediction using CFD and data-driven surrogate models
    Siddiqa, Sadia
    Chang, Kyoungsik
    Naqvi, Sahrish Batool
    Azam, Muhammad
    Molla, Md. Mamun
    Nguyen, K. Hoan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 156
  • [25] An interpretable data-driven method for degradation prediction of proton exchange membrane fuel cells based on temporal fusion transformer and covariates
    Li, Hongwei
    Qiao, Binxin
    Hou, Zhicheng
    Liu, Junnan
    Yang, Yue
    Lu, Guolong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (66) : 25958 - 25971
  • [26] Parameter study of high-temperature proton exchange membrane fuel cell using data-driven models
    Zhu, Guangya
    Chen, Weiwei
    Lu, Shihua
    Chen, Xuewei
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (54) : 28958 - 28967
  • [27] Uncertainty assessment of a semi-empirical output voltage model for proton exchange membrane fuel cells
    Liu, Xiangwan
    Yang, Yang
    Zhang, Lingxian
    Zhou, Shenpei
    Xu, Lamei
    Xie, Changjun
    Zhao, Bo
    Zhang, Leiqi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (29) : 11071 - 11085
  • [28] Performance of a proton exchange membrane fuel cell stack
    Johnson, R
    Morgan, C
    Witmer, D
    Johnson, T
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2001, 26 (08) : 879 - 887
  • [29] Performance of a proton exchange membrane fuel cell stack
    Johnson, R.
    Morgan, C.
    Witmer, D.
    Johnson, T.
    International Journal of Non-Linear Mechanics, 2001, 36 (08) : 879 - 887
  • [30] Performance Degradation and Life Prediction of Proton Exchange Membrane Fuel Cell
    Jia, Xueli
    Liu, Xiaohui
    Zhou, Yilin
    2022 PROGNOSTICS AND HEALTH MANAGEMENT CONFERENCE, PHM-LONDON 2022, 2022, : 433 - 437