Electrochemical Sensor for Simple and Sensitive Determination of Hydroquinone in Water Samples Using Modified Glassy Carbon Electrode

被引:12
|
作者
Karami-Kolmoti, Parisa [1 ]
Beitollahi, Hadi [2 ]
Modiri, Sina [3 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman 7631133131, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman 7631133131, Iran
[3] Grad Univ Adv Technol, Polymer Dept, Kerman 7631133131, Iran
关键词
electrochemical sensing; hydroquinone; voltammetry; modified electrode; MnO2; NRs; GO nanocomposite; GRAPHENE OXIDE; VOLTAMMETRIC SENSOR; NANOPARTICLE; COMPOSITE; OXIDATION; CATECHOL; NANOCOMPOSITE; FABRICATION; NANOSHEETS; ARBUTIN;
D O I
10.3390/biomedicines11071869
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study addressed the use of manganese dioxide nanorods/graphene oxide nanocomposite (MnO2 NRs/GO) for modifying a glassy carbon electrode (GCE). The modified electrode (MnO2 NRs/GO/GCE) was used as an electrochemical sensor for the determination of hydroquinone (HQ) in water samples. Differential pulse voltammetry (DPV), cyclic voltammetry (CV), and chronoamperometry were used for more analysis of the HQ electrochemical behavior. Analyses revealed acceptable electrochemical functions with lower transfer resistance of electrons and greater conductivity of the MnO2 NRs/GO/GCE. The small peak-to-peak separation is an indication of a rapid electron transfer reaction. Therefore, this result is probably related to the effect of the MnO2 NRs/GO nanocomposite on the surface of GCE. In the concentration range of 0.5 & mu;M to 300.0 & mu;M with the detection limit as 0.012 & mu;M, there was linear response between concentration of HQ and the current. The selectivity of the modified electrode was determined by detecting 50.0 & mu;M of HQ in the presence of various interferent molecules. At the end, the results implied the acceptable outcome of the prepared electrode for determining HQ in the water samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Electrochemical Determination of Hydroquinone and Catechol Using Multi-walled Carbon Nanotubes/eosin Y Modified Glassy Carbon Electrode
    Zheng, Shengbiao
    Liu, Jing
    Liu, Renhao
    Hui, Zhenzhen
    Tang, Jing
    Wang, Xuchun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6234 - 6246
  • [32] A Novel Sensitive Electrochemical Sensor Based on Nickel Chloride Solution Modified Glassy Carbon Electrode for Curcumin Determination
    Zokhtareh, Rosan
    Rahimnejad, Mostafa
    ELECTROANALYSIS, 2018, 30 (05) : 921 - 927
  • [33] Highly Sensitive and Selective Electrochemical Sensor Based on Polyglycine Modified Glassy Carbon Electrode for Simultaneous Determination of Amlodipine and Ramipril from Biological Samples
    Doulache, Merzak
    Bakirhan, Nurgul K.
    Saidat, Boubakeur
    Ozkan, Sibel A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [34] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Lemma Teshome Tufa
    Khalid Siraj
    Tesfaye Refera Soreta
    Russian Journal of Electrochemistry, 2013, 49 : 59 - 66
  • [35] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Tufa, Lemma Teshome
    Siraj, Khalid
    Soreta, Tesfaye Refera
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (01) : 59 - 66
  • [36] Electrochemical Determination of Rutin in Herbal Samples Using CuO/CNT composite Modified Glassy Carbon Electrode
    Liu, Zhiyang
    Liu, Yan
    Tan, Zhongyu
    Liu, Ying
    Meng, Linglong
    Yang, Sheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (07):
  • [37] Electrochemical Determination of Caffeine Content in Ethiopian Coffee Samples Using Lignin Modified Glassy Carbon Electrode
    Amare, Meareg
    Aklog, Senait
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
  • [38] A simple electrochemical platform for detection of nitrobenzene in water samples using an alumina polished glassy carbon electrode
    Thirumalraj, Balamurugan
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Thangavelu, Kokulnathan
    Periakaruppan, Prakash
    Liu, Xiao-Heng
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 475 : 154 - 160
  • [39] Fabrication of a composite modified glassy carbon electrode: a highly selective, sensitive and rapid electrochemical sensor for silver ion detection in river water samples
    Azhari, Syaza
    Sathishkumar, Palanivel
    Ahamad, Rahmalan
    Ahmad, Farediah
    Yusoff, Abdull Rahim Mohd
    ANALYTICAL METHODS, 2016, 8 (28) : 5712 - 5721
  • [40] Electrochemical Determination of Carbendazim in Water Base on Carbon Dots Modified Glassy Carbon Electrode
    Bian, Linyan
    Li, Chunli
    Zong, Haitao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (05): : 3675 - 3685