Dynamic modeling and thermodynamic analysis of lithium bromide absorption refrigeration system using Modelica

被引:9
|
作者
Zhou, Yujie [1 ]
Pan, Lei [1 ]
Han, Xu [2 ]
Sun, Li [1 ]
机构
[1] Southeast Univ, Natl Engn Res Ctr Power Generat Control & Safety, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Harvard Univ, Ctr Green Bldg & Cities, Grad Sch Design, Cambridge, MA 02138 USA
基金
中国国家自然科学基金;
关键词
Lithium bromide absorption refrigeration; Dynamic modeling; Modelica; Finite volume method; Energy and exergy analysis; SIMULATION; CHILLER; PERFORMANCE; ENERGY; WATER; PAIR;
D O I
10.1016/j.applthermaleng.2023.120106
中图分类号
O414.1 [热力学];
学科分类号
摘要
Lithium bromide absorption refrigeration system (ARS) is promising in utilizing industrial exhaust heat and improving energy efficiency. ARS consists of a generator, absorber, condenser, evaporator, solution heat exchanger, pump, and valves. To better operate ARS in a changing environment, it is essential to conduct dy- namic modeling and analysis, which might be challenging and cumbersome with conventional modeling tools. Object-oriented, acausal modeling language Modelica can effectively address the modeling limitations on this multi-domain energy system, which provides an opportunity for rapid prototyping and dynamic modeling. Therefore, a customized Modelica library for dynamic modeling of the single-effect lithium bromide ARS is developed. Specifically, the dynamics of the main components including the generator, absorber and heat ex- changers are modeled based on the mass/energy/momentum conservation laws. To capture the alteration of the medium state, the finite volume method is adopted in the modeling of heat exchangers. The model is well - validated under on-design and off-design conditions. Then, energy analysis is conducted to find the optimal working point. The COP reaches the maximum value of 0.793 when hot/cold water flowrate is 0.9 m3/h and 3 m3/h. And exergy analysis supports the above analysis from the perspective of the second law. At last, dynamic responses of the hot/cold water flowrate/temperature are investigated. Dynamic simulation reveals the response rapidity of variables, strong coupling, and different transient trends (overshoot or initial inverse). Additionally, the maximum/minimum vapor quality at the evaporator/condenser outlet is 1.005/0.022.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Thermodynamic evaluation of new absorbent mixtures of lithium bromide and organic salts for absorption refrigeration machines
    Donate, M
    Rodriguez, L
    De Lucas, A
    Rodríguez, JF
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (01): : 30 - 35
  • [12] OPTIMUM PARAMETRIC ANALYSIS BASED ON THERMODYNAMIC MODELING OF A COMPRESSION ABSORPTION CASCADE REFRIGERATION SYSTEM
    Ansari, Naushad Ahmad
    Arora, Akhilesh
    Samsher
    Manjunath, K.
    JOURNAL OF THERMAL ENGINEERING, 2020, 6 (04): : 559 - 576
  • [13] Dynamic testing and modeling of a diffusion absorption refrigeration system
    Ben Jemaa, Radhouane
    Mansouri, Rami
    Bellagi, Ahmed
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 249 - 258
  • [14] Energy economic comparison of vapor compression and lithium bromide absorption refrigeration system
    Zhang, DC
    Zou, SH
    Chen, HX
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 629 - 635
  • [15] THERMODYNAMIC ANALYSIS OF A SINGLE EFFECT LITHIUM BROMIDE WATER ABSORPTION SYSTEM USING WASTE HEAT IN SUGAR INDUSTRY
    Kumar, Balaji
    Selvarasan, Iniyan
    Annadurai, Gurubalan
    Ramalingam, Senthilkumar
    THERMAL SCIENCE, 2018, 22 (01): : 507 - 517
  • [16] Thermodynamic analysis of a single effect lithium bromide water absorption system using waste heat in sugar industry
    Kumar B.
    Selvarasan I.
    Annadurai G.
    Ramalingam S.
    Kumar, Balaji (mr.kbalaj@gmail.com), 2018, Serbian Society of Heat Transfer Engineers (22): : 507 - 517
  • [17] LITHIUM BROMIDE ABSORPTION REFRIGERATION - A CALCULATOR PROGRAM.
    Bogart, Marcel J.P.
    ASHRAE Journal, 1982, 24 (08) : 23 - 28
  • [18] Thermodynamic modeling and sensitivity analysis of ejector in refrigeration system
    Liu, Jiapeng
    Wang, Lei
    Jia, Lei
    Wang, Xinli
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 485 - 492
  • [19] Application of air-gap membrane distillation in lithium bromide absorption refrigeration system
    Li, Lian
    Chen, Zhi
    Yang, Jinfei
    Wang, Jihui
    Li, Jianming
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2020, 39 (01): : 80 - 88
  • [20] Thermodynamic analysis of absorption refrigeration system based on entropy generation
    Kaynakli, Omer
    Yamankaradeniz, Recep
    CURRENT SCIENCE, 2007, 92 (04): : 472 - 479