Dynamic modeling and thermodynamic analysis of lithium bromide absorption refrigeration system using Modelica

被引:9
|
作者
Zhou, Yujie [1 ]
Pan, Lei [1 ]
Han, Xu [2 ]
Sun, Li [1 ]
机构
[1] Southeast Univ, Natl Engn Res Ctr Power Generat Control & Safety, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Harvard Univ, Ctr Green Bldg & Cities, Grad Sch Design, Cambridge, MA 02138 USA
基金
中国国家自然科学基金;
关键词
Lithium bromide absorption refrigeration; Dynamic modeling; Modelica; Finite volume method; Energy and exergy analysis; SIMULATION; CHILLER; PERFORMANCE; ENERGY; WATER; PAIR;
D O I
10.1016/j.applthermaleng.2023.120106
中图分类号
O414.1 [热力学];
学科分类号
摘要
Lithium bromide absorption refrigeration system (ARS) is promising in utilizing industrial exhaust heat and improving energy efficiency. ARS consists of a generator, absorber, condenser, evaporator, solution heat exchanger, pump, and valves. To better operate ARS in a changing environment, it is essential to conduct dy- namic modeling and analysis, which might be challenging and cumbersome with conventional modeling tools. Object-oriented, acausal modeling language Modelica can effectively address the modeling limitations on this multi-domain energy system, which provides an opportunity for rapid prototyping and dynamic modeling. Therefore, a customized Modelica library for dynamic modeling of the single-effect lithium bromide ARS is developed. Specifically, the dynamics of the main components including the generator, absorber and heat ex- changers are modeled based on the mass/energy/momentum conservation laws. To capture the alteration of the medium state, the finite volume method is adopted in the modeling of heat exchangers. The model is well - validated under on-design and off-design conditions. Then, energy analysis is conducted to find the optimal working point. The COP reaches the maximum value of 0.793 when hot/cold water flowrate is 0.9 m3/h and 3 m3/h. And exergy analysis supports the above analysis from the perspective of the second law. At last, dynamic responses of the hot/cold water flowrate/temperature are investigated. Dynamic simulation reveals the response rapidity of variables, strong coupling, and different transient trends (overshoot or initial inverse). Additionally, the maximum/minimum vapor quality at the evaporator/condenser outlet is 1.005/0.022.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Second law-based thermodynamic analysis of water-lithium bromide absorption refrigeration system
    Kilic, Muhsin
    Kaynakli, Omer
    ENERGY, 2007, 32 (08) : 1505 - 1512
  • [2] Analysis of Aqueous Lithium Bromide Absorption Refrigeration Systems
    You, Dongchuan
    Metghalchi, Hameed
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (01):
  • [3] COP optimization analysis of a lithium bromide absorption refrigeration system based on AGMD
    Song Y.
    Li L.
    Chen Z.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (S1): : 150 - 155
  • [4] Dynamic modeling of an absorption refrigeration system using ionic liquids
    Cai, Weihua
    Sen, Mihir
    Paolucci, Samuel
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 6: ENERGY SYSTEMS: ANALYSIS, THERMODYNAMICS AND SUSTAINABILITY, 2008, : 227 - 236
  • [5] Energetic analysis of single stage lithium bromide water absorption refrigeration system.
    Patel, Haresh A.
    Patel, L. N.
    Jani, Darshan
    Christian, Amit
    3RD INTERNATIONAL CONFERENCE ON INNOVATIONS IN AUTOMATION AND MECHATRONICS ENGINEERING 2016, ICIAME 2016, 2016, 23 : 488 - 495
  • [6] Thermodynamic analysis of a lithium bromide/water absorption system for cooling and heating applications
    Lee, SF
    Sherif, SA
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (11) : 1019 - 1031
  • [7] Efficiency Comparison of Thermodynamic Cycles of Lithium Bromide-Water Absorption Refrigeration Machines
    Malinina, O. S.
    Baranenko, A., V
    OIL AND GAS ENGINEERING (OGE-2020), 2020, 2285
  • [8] Application of vacuum membrane distillation to lithium bromide absorption refrigeration system
    Wang, Zanshe
    Gu, Zhaolin
    Feng, Shiyu
    Li, Yun
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07): : 1587 - 1596
  • [9] LITHIUM BROMIDE ABSORPTION REFRIGERATION - A CALCULATOR PROGRAM
    BOGART, MJP
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1982, 24 (08): : 23 - 28
  • [10] Simulation on the Performance of Lithium Bromide Absorption-Refrigeration System using Heat Pipe Exchangers
    Zhang, Ying-cai
    Zhang, Yun-feng
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 321 - 324