Broadband dual-comb hyperspectral imaging and adaptable spectroscopy with programmable frequency combs

被引:3
|
作者
Giorgetta, Fabrizio R. [1 ,2 ]
Deschenes, Jean-Daniel [3 ]
Lieber, Richard L. [4 ,5 ]
Coddington, Ian [1 ]
Newbury, Nathan R. [1 ]
Baumann, Esther [1 ,2 ]
机构
[1] Natl Inst Stand & Technol, Commun Technol Lab, Boulder, CO 80305 USA
[2] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
[3] Octosig Consulting, Quebec City, PQ G2K1X6, Canada
[4] Shirley Ryan Abil Lab Chicago, Chicago, IL 60611 USA
[5] Hines VA Med Ctr Chicago, Chicago, IL 60141 USA
基金
美国国家卫生研究院;
关键词
We thank T. Bui and B. Washburn for their technical comments and acknowledge funding from the Rehabilitation Institute of Chicago (Shirley Ryan AbilityLab) subaward No. 80335 UCB.Y1 and NIST;
D O I
10.1063/5.0179270
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We explore the advantages of a free-form dual-comb spectroscopy (DCS) platform based on time-programmable frequency combs for real-time, penalty-free apodized scanning. In traditional DCS, the fundamental spectral point spacing, which equals the comb repetition rate, can be excessively fine for many applications. While fine point spacing is not itself problematic, it comes with the penalty of excess acquisition time. Post-processing apodization (windowing) can be applied to tailor the resolution to the sample, but only with a deadtime penalty proportional to the degree of apodization. The excess acquisition time remains. With free-form DCS, this deadtime is avoided by programming a real-time apodization pattern that dynamically reverses the pulse periods between the dual frequency combs. In this way, one can tailor the spectrometer's resolution and update rate to different applications without penalty. We show the operation of a free-form DCS system where the spectral resolution is varied from the intrinsic fine 160 MHz up to 822 GHz by applying tailored real-time apodization. Because there is no deadtime penalty, the spectral signal-to-noise ratio increases linearly with resolution by 5000x over this range, as opposed to the square root increase observed for post-processing apodization in traditional DCS. We explore the flexibility to change resolution and update rate to perform hyperspectral imaging at slow camera frame rates, where the penalty-free apodization allows for optimal use of each frame. We obtain dual-comb hyperspectral movies at a 20 Hz spectrum update rate with broad optical spectral coverage of over 10 THz. (c) 2024 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license(http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Compressive dual-comb spectroscopy
    Akira Kawai
    Takahiro Kageyama
    Ryoichi Horisaki
    Takuro Ideguchi
    Scientific Reports, 11
  • [42] Microring Electro-optic Frequency Comb Sources for Dual-Comb Spectroscopy
    Shams-Ansari, Amirhassan
    Yu, Mengjie
    Chen, Zaijun
    Reimer, Christian
    Zhang, Mian
    Picque, Nathalie
    Loncar, Marko
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [43] Dual-comb photothermal spectroscopy
    Wang, Qiang
    Wang, Zhen
    Zhang, Hui
    Jiang, Shoulin
    Wang, Yingying
    Jin, Wei
    Ren, Wei
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [44] Agri-combs: Open-path dual-comb spectroscopy of livestock emissions
    Herman, Daniel, I
    Hutcherson, Lindsay C.
    Weerasekara, Chinthaka
    Giorgetta, Fabrizio R.
    Cossel, Kevin C.
    Colacion, Gabriel M.
    Newbury, Nathan R.
    Welch, Stephen M.
    DePaola, Brett D.
    Coddington, Ian
    Santos, Eduardo A.
    Washburn, Brian R.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [45] Dual-comb spectroscopy of methan based on an Erbium dual-comb fiber laser
    Chen, Jie
    Zhao, Xin
    Wu, Yuehan
    Li, Ting
    Wang, Ruliu
    Li, Qian
    Yin, Siyao
    Liu, Jiansheng
    Zheng, Zheng
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [46] Bidirectional frequency-shifting loop for dual-comb spectroscopy
    Duran, Vicente
    Djevarhidjian, Leo
    Guillet de Chatellus, Hugues
    OPTICS LETTERS, 2019, 44 (15) : 3789 - 3792
  • [47] Combined time and frequency spectroscopy with engineered dual-comb spectrometer
    Ghosh, Sutapa
    Eisenstein, Gadi
    PHYSICAL REVIEW RESEARCH, 2023, 5 (03):
  • [48] Dual-comb single-pixel imaging for scan-less hyperspectral imaging
    Shibuya, Kyuki
    Minamikawa, Takeo
    Mizutani, Yasuhiro
    Yasui, Takeshi
    Iwata, Tetsuo
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,
  • [49] Two-crystal Optical Parametric Oscillator for Broadband Dual-comb Spectroscopy
    Jin, Yuwei
    Cristescu, Simona M.
    Harren, Frans J. M.
    Mandon, Julien
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [50] Dual-Comb Hyperspectral Imaging with a High-Framerate Infrared Detector Array
    Voumard, Thibault
    Wildi, Thibault
    Brasch, Victor
    Gutierrez Alvarez, Raul
    Vergara Ogando, German
    Herr, Tobias
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,