Aptamer-based fluorescent sensor for highly sensitive detection of methamphetamine

被引:4
|
作者
Wang, Yandan [1 ,2 ,3 ]
Wang, Zheyu [1 ,2 ,3 ]
Tong, Yishuo [1 ,2 ,3 ]
Zhang, Dan [1 ,2 ,3 ]
Yun, Keming [1 ,2 ,3 ]
Yan, Jiangwei [1 ,2 ,3 ,4 ]
Niu, Weifen [1 ,2 ,3 ,4 ]
机构
[1] Shanxi Med Univ, Sch Forens Med, Jinzhong, Shanxi, Peoples R China
[2] Shanxi Key Lab Forens Med, Jinzhong, Shanxi, Peoples R China
[3] Key Lab Forens Toxicol, Minist Publ Secur, Jinzhong, Shanxi, Peoples R China
[4] Shanxi Med Univ, Sch Forens Med, Jinzhong 030600, Shanxi, Peoples R China
关键词
binding active site; fluorescent aptasensor; graphene oxide (GO); methamphetamine (METH); IN-VITRO SELECTION; PHASE MICROEXTRACTION; ORAL FLUID; AMPHETAMINE; METHYLAMPHETAMINE; NANOPARTICLES; BIOSENSORS; ASSAY;
D O I
10.1002/bio.4687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a fluorescence aptamer sensor was achieved by employing the fundamental principle of fluorescence resonance energy transfer. By employing molecular modeling technologies to identify the binding site, the high-affinity aptamer APT-40nt was derived from the whole sequence and utilized on the graphene oxide (GO) fluorescent platform for the purpose of achieving a highly sensitive detection of methamphetamine (METH). The aptamer tagged with fluorescein (FAM) dye undergoes quenching in the presence of GO due to pi-stacking interaction. With the addition of the target, the aptamer that has been tagged was detached from the GO surface, forming a stable complex with METH. This process resulted in fluorescence restoration of the system, and the degree of fluorescence restoration was proportional to METH concentration in the linear range of 1-50 and 50-200 nM. Notably, under optimized conditions, the detection limit of this aptasensor was as low as 0.78 nM, which meets the detection limit requirements of METH detection in saliva and urine in some countries and regions. Moreover, other common illicit drugs and metabolites had minimizing interference with the determination. The established aptasensor, therefore, has been successfully applied to detect METH in saliva and urine samples and exhibited satisfactory recoveries (87%-111%). This aptasensor has the advantages of low detection limit, excellent selectivity, ease of operation, and low cost, providing a promising strategy for on-site detection of METH in saliva and urine. A straightforward, selective, and low-cost fluorescence aptamer sensor based on graphene oxide (GO) as a fluorescence quencher for highly sensitive detection of methamphetamine (METH) was developed. The aptasensor has a low detection limit (0.78 nM) and excellent selectivity, which has been successfully applied to detect METH in saliva and urine samples. image
引用
收藏
页数:11
相关论文
共 50 条
  • [21] RNA aptamer-based optical nanostructured sensor for highly sensitive and label-free detection of antigen–antibody reactions
    Ha Minh Hiep
    Masato Saito
    Yoshikazu Nakamura
    Eiichi Tamiya
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2575 - 2581
  • [22] Highly sensitive protein detection by aptamer-based single-molecule kinetic fingerprinting
    Chatterjee, Tanmay
    Johnson-Buck, Alexander
    Walter, Nils G.
    BIOSENSORS & BIOELECTRONICS, 2022, 216
  • [23] Highly Sensitive Aptamer-Based Method for the Detection of Cardiac Biomolecules on Silicon Dioxide Surfaces
    Hlukhova, H.
    Menger, M.
    Offenhaeusser, A.
    Vitusevich, S.
    MRS ADVANCES, 2018, 3 (27): : 1535 - 1541
  • [24] Aptamer-Based Fluorescent Biosensors
    Wang, R. E.
    Zhang, Y.
    Cai, J.
    Cai, W.
    Gao, T.
    CURRENT MEDICINAL CHEMISTRY, 2011, 18 (27) : 4175 - 4184
  • [25] Highly Sensitive Aptamer-Based Method for the Detection of Cardiac Biomolecules on Silicon Dioxide Surfaces
    H. Hlukhova
    M. Menger
    A. Offenhäusser
    S. Vitusevich
    MRS Advances, 2018, 3 (27) : 1535 - 1541
  • [26] Sensitive and Homogeneous Detection System with Aptamer-Based Biosensor
    Tsukakoshi, Kaori
    Ikebukuro, Kazunori
    SENSORS AND MATERIALS, 2016, 28 (10) : 1083 - 1089
  • [27] Aptamer-based Upconversion Fluorescence Sensor for Doxorubicin Detection
    Jingwen Mo
    Shichang Wang
    Jiaying Zeng
    Xiong Ding
    Journal of Fluorescence, 2023, 33 : 1897 - 1905
  • [28] Aptamer-based Upconversion Fluorescence Sensor for Doxorubicin Detection
    Mo, Jingwen
    Wang, Shichang
    Zeng, Jiaying
    Ding, Xiong
    JOURNAL OF FLUORESCENCE, 2023, 33 (05) : 1897 - 1905
  • [29] Aptamer-based sensor arrays for the detection and quantitation of proteins
    Kirby, R
    Cho, EJ
    Gehrke, B
    Bayer, T
    Park, YS
    Neikirk, DP
    McDevitt, JT
    Ellington, AD
    ANALYTICAL CHEMISTRY, 2004, 76 (14) : 4066 - 4075
  • [30] A simple and label-free fluorescent DNA sensor for visual detection of aptamer-based berberine
    Zhang, Wenjuan
    Luo, Mingwan
    Chen, Juan
    Li, Zhengxing
    Wei, Xian
    Wu, Miqi
    Yang, Shengli
    He, Yuanju
    Wang, Xiaoping
    Xiao, Zhiyou
    ANALYTICAL METHODS, 2024, 16 (42) : 7130 - 7138