Deep Learning-Based Intraoperative Stent Graft Segmentation on Completion Digital Subtraction Angiography During Endovascular Aneurysm Repair

被引:6
|
作者
Kappe, Kaj O. [1 ,2 ]
Smorenburg, Stefan P. M. [1 ,2 ]
Hoksbergen, Arjan W. J. [1 ,2 ]
Wolterink, Jelmer M. [3 ]
Yeung, Kak Khee [1 ,2 ]
机构
[1] Vrije Univ, Amsterdam Univ Med Ctr, Dept Surg, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Univ Twente, Tech Med Ctr, Dept Appl Math, Enschede, Netherlands
关键词
Deep learning; Artificial Intelligence; Digital Subtraction Angiography; Endovascular Aneurysm Repair; EVAR; Segmentation; Automatic; Intraoperative; Abdominal Aortic Aneurysm; AAA; DEFORMATIONS; PREDICTION; EVAR;
D O I
10.1177/15266028221105840
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Modern endovascular hybrid operating rooms generate large amounts of medical images during a procedure, which are currently mostly assessed by eye. In this paper, we present fully automatic segmentation of the stent graft on the completion digital subtraction angiography during endovascular aneurysm repair, utilizing a deep learning network. Technique: Completion digital subtraction angiographies (cDSAs) of 47 patients treated for an infrarenal aortic aneurysm using EVAR were collected retrospectively. A two-dimensional convolutional neural network (CNN) with a U-Net architecture was trained for segmentation of the stent graft from the completion angiographies. The cross-validation resulted in an average Dice similarity score of 0.957 +/- 0.041 and median of 0.968 (IQR: 0.950 - 0.976). The mean and median of the average surface distance are 1.266 +/- 1.506 mm and 0.870 mm (IQR: 0.490 - 1.430), respectively. Conclusion: We developed a fully automatic stent graft segmentation method based on the completion digital subtraction angiography during EVAR, utilizing a deep learning network. This can provide the platform for the development of intraoperative analytical applications in the endovascular hybrid operating room such as stent graft deployment accuracy, endoleak visualization, and image fusion correction.
引用
收藏
页码:822 / 827
页数:6
相关论文
共 50 条
  • [41] Prevention of Kinked Stent Graft Limb Due to Severe Angulated Proximal Neck during Endovascular Repair for Abdominal Aortic Aneurysm
    Oh, Pyung Chun
    Kim, Minsu
    Shin, Eak Kyun
    Kang, Woong Chol
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 24 (02) : 106 - 109
  • [42] Diagnosis of intracranial aneurysms by computed tomography angiography using deep learning-based detection and segmentation
    You, Wei
    Feng, Junqiang
    Lu, Jing
    Chen, Ting
    Liu, Xinke
    Wu, Zhenzhou
    Gong, Guoyang
    Sui, Yutong
    Wang, Yanwen
    Zhang, Yifan
    Ye, Wanxing
    Chen, Xiheng
    Lv, Jian
    Wei, Dachao
    Tang, Yudi
    Deng, Dingwei
    Gui, Siming
    Lin, Jun
    Chen, Peike
    Wang, Ziyao
    Gong, Wentao
    Wang, Yang
    Zhu, Chengcheng
    Zhang, Yue
    Saloner, David A.
    Mitsouras, Dimitrios
    Guan, Sheng
    Li, Youxiang
    Jiang, Yuhua
    Wang, Yan
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [43] Automated Deep Learning-Based Region-of-Interest Segmentation in Ultra-widefield Angiography
    Harwood, Samuel
    Whitney, Jon
    Karla, Gagan
    Yordi, Sari
    Cakir, Yavuz
    Budrevich, Jordan
    Bonnay, Michelle
    Srivastava, Sunil
    Ehlers, Justis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (09)
  • [44] Dislodgement of a renal stent causing renal infarct during endovascular abdominal aortic aneurysm repair with chimney graft for juxtarenal aortic aneurysm: A rare complication
    Tsang, Yi-Po
    Yien, Renny Ling-Chu
    Tang, Kendrick Yip-Kan
    Lo, Sherwin Shing-Wai
    Li, Michael Ka-Wah
    SURGICAL PRACTICE, 2014, 18 (02) : 102 - 104
  • [45] Investigating Staining Variance Effects on Deep Learning-Based Semantic Segmentation in Digital Pathology
    Marzouki, Amine
    Vagena, Zografoula
    Kurtz, Camille
    Lomenie, Nicolas
    DIGITAL AND COMPUTATIONAL PATHOLOGY, MEDICAL IMAGING 2024, 2024, 12933
  • [46] Deep learning-based automatic segmentation of bone graft material after maxillary sinus augmentation
    Tao, Baoxin
    Xu, Jiangchang
    Gao, Jie
    He, Shamin
    Jiang, Shuanglin
    Wang, Feng
    Chen, Xiaojun
    Wu, Yiqun
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 964 - 972
  • [47] Comparison of time-resolved CT-angiography, contrast-enhanced ultrasound and digital subtraction angiography in a patient with a small type II endoleak after endovascular aneurysm repair
    Sommer, Wieland H.
    Hoffmann, Ralf. T.
    Becker, Christoph R.
    Reiser, Maximilian F.
    Clevert, Dirk A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2010, 45 (01) : 19 - 25
  • [48] Internal iliac artery occlusion using a stent-graft tunnel during endovascular aneurysm repair: A new alternative to coil embolization
    Rajasinghe, HA
    Pigott, JP
    Kritpracha, B
    Corbey, MJ
    Beebe, HG
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (06) : 1082 - 1086
  • [49] A case report of intentional occlusion of an aberrant right subclavian artery during endovascular stent-graft repair of a descending aortic aneurysm
    Hutton, M
    Wolf, B
    Boyne, N
    Tripathi, R
    Sieunarine, K
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (02) : 222 - 224
  • [50] First in man: PERCUTEK Tianyi® stent-graft greatly facilitated in situ fenestration during thoracic aortic aneurysm endovascular repair
    Wang, Shuangjing
    Fu, Weiguo
    Wang, Lixin
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2025, 9 (01)