Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens

被引:9
|
作者
Al-Amri, Saad Abdulrahman J. [1 ,2 ,3 ]
Alio, Jorge L. [1 ,3 ]
Milan-Castillo, Roberto [1 ]
D'Oria, Francesco [1 ,4 ]
Martinez-Abad, Antonio [1 ]
Yebana, Pilar [1 ]
Subirana, Nuria [1 ]
Al-Harbi, Ziyad [1 ,5 ]
Plaza-Puche, Ana B. [1 ]
Alio del Barrio, Jorge L. [1 ,3 ]
机构
[1] VISSUM Miranza Grp, Cornea Cataract & Refract Surg Unit, Alicante, Spain
[2] Prince Sultan Med Mil City, Dept Ophthalmol, Riyadh, Saudi Arabia
[3] Univ Miguel Hernandez, Dept Ophthalmol, Alicante, Spain
[4] Univ Bari, Sect Ophthalmol, Dept Basic Med Sci Neurosci & Sense Organs, Bari, Italy
[5] Al Nakheel Med Ctr, Riyadh, Saudi Arabia
关键词
PATIENT SATISFACTION; IOL DESIGNS; OUTCOMES; RANGE;
D O I
10.3928/1081597X-20221130-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. METHODS: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). RESULTS: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 +/- 0.12 and 0.31 +/- 0.07, respectively), followed by the AcrySof SA60AT (0.39 +/- 0.10 and 0.27 +/- 0.07) and AcrySof IQ Vivity (0.34 +/- 0.11 and 0.24 +/- 0.09) (P <.001). The AcrySof IQ Vivity and monofocal IOLs were comparable (P >.05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 +/- 0.06 at 3 mm; P <.001) compared to the monofocal AcrySof SA60AT (0.24 +/- 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 +/- 0.06 at 3 mm) groups. The PSF with LOA was comparable (P >.05) among the three groups at both the 3and 4-mm pupil size. CONCLUSIONS: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and monofocal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA).
引用
收藏
页码:103 / +
页数:9
相关论文
共 50 条
  • [41] Extended depth-of-focus (EDOF) AcrySof® IQ Vivity® intraocular lens implant: a real-life experience
    Arrigo, Alessandro
    Gambaro, Gianpiera
    Fasce, Francesco
    Aragona, Emanuela
    Figini, Innocente
    Bandello, Francesco
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (09) : 2717 - 2722
  • [42] Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF)
    Acar, Banu Torun
    Duman, Erkan
    Simsek, Saban
    BMC OPHTHALMOLOGY, 2016, 16
  • [43] AcrySof IQ PanOptix Intraocular Lens Versus Extended Depth of Focus Intraocular Lens and Trifocal Intraocular Lens: A Clinical Overview
    Sudhir, Rachapalle Reddi
    Dey, Arindam
    Bhattacharrya, Shovan
    Bahulayan, Amit
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (04): : 335 - 349
  • [44] Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF)
    Banu Torun Acar
    Erkan Duman
    Saban Simsek
    BMC Ophthalmology, 16
  • [45] Visual Performance of a New Extended Depth-of-Focus Intraocular Lens Compared to a Distance-Dominant Diffractive Multifocal Intraocular Lens
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Balducci, Nicole
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 228 - +
  • [46] Quality of view through extended depth of focus intraocular lens in a model eye
    Makoto Inoue
    Nina Teresa Aicher
    Yuji Itoh
    Hiroko Bissen-Miyajima
    Akito Hirakata
    Japanese Journal of Ophthalmology, 2021, 65 : 569 - 580
  • [47] Quality of view through extended depth of focus intraocular lens in a model eye
    Inoue, Makoto
    Aicher, Nina Teresa
    Itoh, Yuji
    Bissen-Miyajima, Hiroko
    Hirakata, Akito
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (04) : 569 - 580
  • [48] Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular Lens
    Corbett, Dean
    Black, Daniel
    Roberts, Timothy V.
    Cronin, Brendan
    Gunn, David
    Bala, Chandra
    Versace, Patrick
    Tsai, Linda
    Papadatou, Eleni
    Alarcon, Aixa
    Vilupuru, Srividhya
    EYE, 2024, 38 (SUPPL 1) : 9 - 14
  • [49] Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk
    Attia, Mary S. A.
    Auffarth, Gerd U.
    Kretz, Florian T. A.
    Tandogan, Tamer
    Rabsilber, Tanja M.
    Holzer, Mike P.
    Khoramnia, Ramin
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 664 - +
  • [50] Initial clinical evaluation of a novel extended-depth-of-focus intraocular lens
    Schallhorn, Steven
    Schallhorn, Julie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)