Box-Behnken Design-Based Optimized Kinetic Approach to Develop an Eco-friendly Analytical Method for the Quantitation of Glimepiride Using Spectrophotometry

被引:2
|
作者
Rahman, Habibur [1 ]
机构
[1] Royal Commiss Jubail, Dept Gen Studies, Jubail Ind Coll, Jubail Ind City 31961, Saudi Arabia
关键词
Kinetic modeling; Box-Behnken design; GLMP; DoE; Validation; Youden's test; Analytical Eco-Scale; POTASSIUM-PERMANGANATE; VALIDATION; HYDROCHLORIDE;
D O I
10.1007/s12247-022-09691-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose The prevalence of type 2 diabetes mellitus is one of the global concerns and almost 80% of diabetic patients are treated with oral antidiabetic drugs. GLMP as a prescribed oral antidiabetic drug for diabetic patients enhanced its necessity. Therefore, it is essential to quantify it in several drug formulations and biological samples. Hence, a simple, eco-friendly, validated kinetic spectrophotometric method was developed for quantifying GLMP in commercial dosage forms. Methods The method was based on the oxidation of the GLMP with potassium permanganate. The reaction was followed spectrophotometrically, measuring an increase in absorbance with time at 605 nm. RSM optimized the influence of preliminary experimental variables for the proposed procedure via BBD, a frequently used DoE. Under the optimized conditions, initial rate, fixed-time (at 6.0 min), and equilibrium method (25.0 min) were adopted for constructing the calibration graphs to determine the amount of GLMP. The robustness of the proposed method was performed, and the effect of selected analytical parameters was investigated with alternative conditions employing Youden and Steiner's test. Results The outcomes of the model were significant. Hence, the performance of the analytical method was validated statistically and through recovery studies using ICH guidelines. Calibration curves were linear in the concentration ranges of 4.0-36.0 mu g/ml with a detection limit of 1.60, 1.02, and 1.13 mu g/ml for the initial rate, fixed-time, and equilibrium method, respectively. The proposed method's greenness profile was assessed using the analytical Eco-Scale and found greener in terms of using harmful reagents, energy consumption, and waste production. Statistical comparison of the results is shown in good agreement with the results found by the reference method, indicating no significant difference in accuracy and precision. Conclusion The proposed validated kinetic method is simple, accurate, low cost, safe, and eco-friendly and might be used in research laboratories, hospitals, and pharmaceutical industries for the routine quality control analysis of GLMP in commercial dosage forms.
引用
收藏
页码:893 / 910
页数:18
相关论文
共 50 条
  • [11] Box-Behnken design for the optimisation of Kabachnik-Fields reaction catalysed by natural kaolinite clay under eco-friendly conditions
    Boukachabia, Mourad
    Guezane-Lakoud, Samia
    Bendjeffal, Hacene
    Haffas, Maamar
    REACTION CHEMISTRY & ENGINEERING, 2024, 9 (05) : 1164 - 1172
  • [12] Condition optimization of eco-friendly RP-HPLC and MCR methods via Box-Behnken design and six sigma approach for detecting antibiotic residues
    Alanazi, Tahani Y. A.
    Pashameah, Rami Adel
    Binsaleh, Ammena Y.
    Mohamed, Mahmoud A.
    Ahmed, Hoda A.
    Nassar, Hossam F.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [13] Box-Behnken design-based optimization for deproteinization of crude polysaccharides in Lycium barbarum berry residue using the Sevag method
    Long, Xiaoyan
    Yan, Quan
    Cai, Linjun
    Li, Guangying
    Luo, Xuegang
    HELIYON, 2020, 6 (05)
  • [14] Eco-friendly and green chromatographic method for the simultaneous determination of chlorocresol and betamethasone dipropionate in topical formulations using Box–Behnken design
    Siva Krishna Muchakayala
    Naresh Kumar Katari
    Thirupathi Dongala
    Vishnu Murthy Marisetti
    Govind Vyas
    Raju V. K. Vegesna
    Journal of the Iranian Chemical Society, 2022, 19 : 1397 - 1412
  • [15] A novel Six Sigma approach and eco-friendly RP-HPLC technique for determination of pimavanserin and its degraded products: Application of Box-Behnken design
    Nassef, Hossam M.
    Ahmed, Hoda A.
    Bashal, Ali H.
    El-Atawy, Mohamed A.
    Alanazi, Tahani Y. A.
    Mahgoub, Samar M.
    Mohamed, Mahmoud A.
    REVIEWS IN ANALYTICAL CHEMISTRY, 2024, 43 (01)
  • [16] Use of hydrogen-bonded supramolecular eutectic solvents for eco-friendly extraction of bioactive molecules from Cymbopogon citratus using Box-Behnken design
    Naseem, Zubera
    Iqbal, Javed
    Zahid, Muhammad
    Shaheen, Asma
    Hussain, Shahid
    Yaseen, Waleed
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2020, 15 (2) : 1487 - 1498
  • [17] A Box-Behnken Design-Based Model for Predicting Power Performance in Microbial Fuel Cells Using Wastewater
    Martinez-Conesa, E. J.
    Ortiz-Martinez, V. M.
    Salar-Garcia, M. J.
    De Los Rios, A. P.
    Hernandez-Fernandez, F. J.
    Lozano, L. J.
    Godinez, C.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2017, 204 (01) : 97 - 104
  • [18] A Box-Behnken design-based chemometric approach to optimize the removal of phosphate ions from water using Punica granatum shells
    Bendjeffal, H.
    Mamine, H.
    Metidji, T.
    Djebli, A.
    Diaf, R.
    Bouhedja, Y.
    PHOSPHORUS SULFUR AND SILICON AND THE RELATED ELEMENTS, 2023, 198 (08) : 632 - 644
  • [19] Dual-action of colloidal ISCOMs: an optimized approach using Box-Behnken design for the management of breast cancer
    Drashti Desai
    Pravin Shende
    Biomedical Microdevices, 2022, 24
  • [20] Optimization of the eco-friendly synthesis of graphene oxide from graphite using Plackett-Burman and Box-Behnken models for industrial production orientation
    Phuc, Nguyen Thien
    Giang, Nguyen Thi Huong
    An, Vu Nguyen Thien Truong
    Nam, Nguyen Thanh Hoai
    Anh, Ly Duc
    Nguyen, Huynh Cam
    An, Hoang
    Phong, Mai Thanh
    Hieu, Nguyen Huu
    CARBON LETTERS, 2023, 33 (02) : 489 - 500