Study on seismic performance of green fiber-reinforced concrete shear wall

被引:4
|
作者
Li, Yan [1 ]
Li, Dong-yi [1 ]
Zhao, Rong-hua [1 ]
Ying, Dao-heng [1 ]
机构
[1] Jilin Jianzhu Univ, Sch Civil Engn, Changchun, Jilin, Peoples R China
关键词
Shear wall; Seismic performance; Green fibers; Incorporation height; Abaqus;
D O I
10.1016/j.istruc.2023.105116
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete shear walls are widely used in civil engineering and it is necessary to study new environ-mental protection methods to improve its seismic performance. The green fibers (namely recycled steel fibers, collectively referred to as green fibers in this article) formed by cutting high quality steel wires extracted from waste tires and have good tensile, flexural, and yield strength. So the improvement effect of green fibers on the seismic performance of concrete shear wall is studied in this paper. Cyclic loading experiments are used to explore the seismic performance of plain concrete shear wall specimen, green fiber-reinforced concrete shear wall specimen mixed with green fibers 1.0 L (L is the length of shear wall, the same as below) and 1.5 L height and fiber volume ratio of 1.5%. The results show that with the addition of green fibers and the increases in incorporation height of green fibers, the ultimate bearing capacity, ductility, and energy dissipation capacity of concrete shear wall specimens gradually increase. As the specimen increases the fiber incorporation height, the ultimate bearing capacity of the shear wall increases, and the ductility and energy dissipation capacity increase, and stiffness degradation of specimens gradually slows down. That is, the seismic performance of shear wall specimens is gradually improved. The error between the experimental values and calculated values obtained by the deduced calculation formula is within the allowable range. The results of Abaqus finite element numerical simulation are in good agreement with the experimental results. And through the numerical simulation of the other two specimens, it can be concluded that the flexural performance of green fiber-reinforced concrete shear wall specimens increases with the increases in fiber volume ratio and the decreases in axial compression ratio. This study can provide a reference for the research on the seismic performance of fiber-reinforced concrete shear wall and the application of steel wires extracted from waste tires in practical engineering.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Seismic Behavior and Detailing of High-Performance Fiber-Reinforced Concrete Coupling Beams and Coupled Wall Systems
    Lequesne, Remy D.
    Parra-Montesinos, Gustavo J.
    Wight, James K.
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (08) : 1362 - 1370
  • [32] PERFORMANCE OF FIBER-REINFORCED CONCRETE PAVEMENT
    PACKARD, RG
    RAY, GK
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1984, 81 (05): : 516 - 516
  • [33] Experimental Study on the Seismic Performance of Macro-Synthetic Fiber-Reinforced Concrete Ductile Columns
    Ma, Hua
    Wang, Honghuan
    Li, Zhenbao
    Sun, Xinyu
    Zhang, Xuewei
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 2345 - 2350
  • [34] Study on the Seismic Behavior of Green High-performance Fiber-reinforced Cementitious Composites Column
    Li, Xiuling
    Luo, Min
    ADVANCED BUILDING MATERIALS AND SUSTAINABLE ARCHITECTURE, PTS 1-4, 2012, 174-177 : 806 - 809
  • [35] Experimental and analytical study on channel shear connectors in fiber-reinforced concrete
    Maleki, Shervin
    Mahoutian, Mehrdad
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (8-9) : 1787 - 1793
  • [36] Behavior and modeling of infill fiber-reinforced concrete damper element for steel-concrete shear wall
    Xia, ZM
    Naaman, AE
    ACI STRUCTURAL JOURNAL, 2002, 99 (06) : 727 - 739
  • [37] Seismic Performance Parameters for Reinforced Concrete-Block Shear Wall Construction
    Shedid, Marwan T.
    El-Dakhakhni, Wael W.
    Drysdale, Robert G.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2010, 24 (01) : 4 - 18
  • [38] Seismic Performance of High-Ductile Fiber-Reinforced Concrete Short Columns
    Deng, Mingke
    Zhang, Yangxi
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [39] Seismic performance of fiber-reinforced concrete interior beam-column joints
    Liang, Xing-wen
    Wang, Ying-jun
    Tao, Yi
    Deng, Ming-ke
    ENGINEERING STRUCTURES, 2016, 126 : 432 - 445
  • [40] Performance Evaluation of Glass Fiber-Reinforced Polymer Shear Reinforcement for Concrete Beams
    Ahmed, Ehab A.
    El-Salakawy, Ehab F.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2010, 107 (01) : 53 - 62