Diagnosis of Interturn Short-Circuit of SRM Based on Ratio of Current Components

被引:7
|
作者
Chen, Hao [1 ,2 ,3 ,4 ]
Fang, Chenghui [1 ,2 ,3 ,4 ]
Dong, Jinlong [5 ]
Lu, Shengli [6 ]
Pires, Vitor [7 ,8 ]
Martins, Joao [9 ]
Aguirre, Miguel Pablo [10 ]
机构
[1] China Univ Min & Technol, Sch Elect Engn, Xuzhou 221116, Peoples R China
[2] Int Joint Res Ctr Cent & Eastern European Countrie, Xuzhou 221008, Peoples R China
[3] Int Cooperat Joint Lab New Energy Power Generat &, Xuzhou 221008, Peoples R China
[4] Xuzhou Key Lab New Energy Elect Vehicle Technol &, Xuzhou 221008, Peoples R China
[5] State Grid Laiwu Power Supply Serv Command Ctr, Jinan 250102, Peoples R China
[6] Nanjing Res Inst Elect Technol, Nanjing 210012, Peoples R China
[7] Polytech Inst Setubal, Setubal Sch Technol, P-2914508 Setubal, Portugal
[8] INESC ID, P-1049001 Lisbon, Portugal
[9] CTS UNINOVA, FCT UNL, Dept Elect Engn, P-2829517 Caparica, Portugal
[10] Inst Tecnol Buenos Aires, C1106ACD, Buenos Aires, Argentina
基金
中国国家自然科学基金;
关键词
Fault diagnosis; interturn short-circuit; switched reluctance motor (SRM); symmetrical component; FAULT-DIAGNOSIS;
D O I
10.1109/TTE.2022.3224596
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interturn short-circuit is a common fault mode of switched reluctance motors (SRMs) that cause changes in the parameters of the motor that can cause vibrations and noise. In this article, a diagnosis method is proposed to detect short-circuit fault. First, the model of a phase winding with interturn short-circuit is built and the fault characteristics are analyzed. Under normal condition, the sinusoidal components of phase currents are mostly a positive sequence with minimum distortion. The frequency signature of the motor is extracted by Fourier analysis when operating in normal conditions. When a fault condition occurs, the symmetry of the phase currents is broken, and both negative and zero sequence components of the phase currents appear. According to the asymmetry, an index, the ratio of negative to positive sequence components of the phase currents, is defined to identify whether the motor is working normally. The proposal is verified by simulations and experiments on a three-phase 12/8 structure SRM under different mechanical operating conditions. In normal condition, the fault index is about 0.02; in 12.5% fault condition, the fault index rises to about 0.07; in 25% fault condition, the fault index rises to about 0.08. According to the experimental results, fault index is robust because it is not influenced by the following parameters: turn on angle, turn off angle, rotor speed, load torque, and so on.
引用
收藏
页码:3319 / 3327
页数:9
相关论文
共 50 条
  • [21] IMPROVED MPPT SHORT-CIRCUIT CURRENT METHOD BY A FUZZY SHORT-CIRCUIT CURRENT ESTIMATOR
    Diaz, Nelson
    Luna, Adriana
    Duarte, Oscar
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 211 - 218
  • [22] PWM Harmonic-Current-Based Interturn Short-Circuit Fault Diagnosis for the Aerospace FTPMSM System Even in the Fault-Tolerant Operation Condition
    Xu, Jinquan
    Tian, Xinlei
    Jin, Wenbo
    Guo, Hong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (04) : 5432 - 5441
  • [23] Diagnosis and Fault-Tolerant Control of Permanent Magnet Synchronous Motors With Interturn Short-Circuit Fault
    Zhang, Jiayuan
    Zhan, Wei
    Ehsani, Mehrdad
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2023, 31 (04) : 1909 - 1916
  • [24] INTERTURN SHORT-CIRCUIT DETECTOR FOR TURBINE-GENERATOR ROTOR WINDINGS
    ALBRIGHT, DR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (02): : 478 - &
  • [25] Accurate Interturn Short-Circuit Faults Diagnosis in PMSMs Under Variable Operating Conditions by Signal Compensation
    Niu, Feng
    Xu, Mingge
    Zhou, Feng
    Huang, Shaopo
    Xu, Zijun
    Zhang, Lu
    Aggarwal, Anmol
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (02) : 3530 - 3542
  • [26] Detection of Interturn Short-Circuit Fault for PMSM With Simple Fault Indicator
    Hang, Jun
    Ding, Shichuan
    Zhang, Jianzhong
    Cheng, Ming
    Chen, Wen
    Wang, Qunjing
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1697 - 1699
  • [27] SHORT-CIRCUIT CURRENT RATINGS
    Neeser, Daniel R.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2014, 20 (05) : 44 - 49
  • [28] Short-circuit Current calculations
    不详
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2005, 122 (05): : A6 - A6
  • [29] Fault Phase Location for Interturn Short-Circuit Faults in Symmetrical Six-Phase PMSMs Based on Subspace Current Residual
    Wang, Huidong
    Hu, Jianhui
    Li, Yong
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (04): : 8336 - 8345
  • [30] PV Control System Based On Short-Circuit Current
    Gana, O.
    Vasar, C.
    Babescu, M.
    Vartosu, A.
    2013 IEEE 8TH INTERNATIONAL SYMPOSIUM ON APPLIED COMPUTATIONAL INTELLIGENCE AND INFORMATICS (SACI 2013), 2013, : 387 - 390