Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis

被引:16
|
作者
Diaconu, Alexandru [1 ]
Holte, Michael Boelstoft [1 ,2 ]
Berg-Beckhoff, Gabriele [3 ]
Pinholt, Else Marie [1 ,2 ]
机构
[1] Univ Hosp Southern Denmark, Dept Oral & Maxillofacial Surg, 3D Lab Denmark, Finsensgade 35, DK-6700 Esbjerg, Denmark
[2] Univ Southern Denmark, Fac Hlth Sci, Dept Reg Hlth Res, Finsensgade 35, DK-6700 Esbjerg, Denmark
[3] Univ Southern Denmark, Fac Hlth Sci, Dept Publ Hlth, Degnevej 14, DK-6705 Esbjerg, Denmark
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 01期
关键词
patient-specific implants; orthognathic surgery; accuracy; stability; three-dimensional; systematic review; meta-analysis; CUSTOMIZED SURGICAL GUIDES; PATIENT-SPECIFIC IMPLANTS; TITANIUM PLATES; CUTTING GUIDES; SUPERIMPOSITION; OSTEOSYNTHESIS; FIXATION; REGISTRATION; VALIDATION; PROTOCOL;
D O I
10.3390/jpm13010125
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65 degrees in pitch. PSIs were up to 0.85 mm and 2.35 degrees more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Unveiling the Impact of Three-Dimensional Technology on Rhinoplasty: A Systematic Review and Meta-analysis
    Werathammo, Methini
    Seresirikachorn, Kachorn
    Charoenlux, Prapitphan
    FACIAL PLASTIC SURGERY, 2024,
  • [22] Accuracy of three-dimensional soft tissue profile prediction in orthognathic surgery
    Yamashita, Amanda Lury
    Iwaki Filho, Liogi
    Ferraz, Flavio Wellington da Silva
    Ramos, Adilson Luiz
    Previdelli, Isolde Terezinha dos Santos
    Pereira, Omar Cleo Neves
    Tolentino, Elen de Souza
    Chicarelli, Mariliani
    Iwaki, Lilian Cristina Vessoni
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2022, 26 (02): : 271 - 279
  • [23] Virtual and traditional surgical planning in orthognathic surgery - systematic review and meta-analysis
    Alkaabi, S.
    Maningky, Melvin
    Helder, Marco N.
    Alsabri, G.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (09): : 1184 - 1191
  • [24] Prophylactic Tranexamic Acid Use in Orthognathic Surgery: A Systematic Review and Meta-analysis
    Baghaie, Hooman
    Shukla, Khilan
    Stone, Jennifer
    Breik, Omar
    Munn, Zachary
    AESTHETIC PLASTIC SURGERY, 2025,
  • [25] Virtual Versus Conventional Planning in Orthognathic Surgery: A Systematic Review and Meta-analysis
    Guilherme Strujak
    Daniel Amaral Alves Marlière
    Yuri de Lima Medeiros
    Odilon Guariza Filho
    João Luiz Carlini
    Vânia Portela Ditzel Westphalen
    Journal of Maxillofacial and Oral Surgery, 2024, 23 : 219 - 228
  • [26] Virtual Versus Conventional Planning in Orthognathic Surgery: A Systematic Review and Meta-analysis
    Strujak, Guilherme
    Marliere, Daniel Amaral Alves
    Medeiros, Yuri de Lima
    Guariza Filho, Odilon
    Carlini, Joao Luiz
    Westphalen, Vania Portela Ditzel
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (02): : 219 - 228
  • [27] Piezoelectric versus conventional techniques for orthognathic surgery: Systematic review and meta-analysis
    Alrefai, Mohamad
    Daboul, Ahmad
    Fleischhacker, Boris
    Landes, Constantin
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2022, 123 (05) : E273 - E278
  • [28] Piezoelectric versus conventional techniques for orthognathic surgery: Systematic review and meta-analysis
    Charles Pagotto, Luis Eduardo
    Santos, Thiago de Santana
    de Abreu de Vasconcellos, Sara Juliana
    Santos, Joanes Silva
    Saquete Martins-Filho, Paulo Ricardo
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (10) : 1607 - 1613
  • [29] Accuracy of three-dimensional soft tissue profile prediction in orthognathic surgery
    Amanda Lury Yamashita
    Liogi Iwaki Filho
    Flávio Wellington da Silva Ferraz
    Adilson Luiz Ramos
    Isolde Terezinha dos Santos Previdelli
    Omar Cléo Neves Pereira
    Elen de Souza Tolentino
    Mariliani Chicarelli
    Lilian Cristina Vessoni Iwaki
    Oral and Maxillofacial Surgery, 2022, 26 : 271 - 279
  • [30] Corticosteroid Administration in Oral and Orthognathic Surgery: A Systematic Review of the Literature and Meta-Analysis
    Dan, Anne E. B.
    Thygesen, Torben H.
    Pinholt, Else M.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (09) : 2207 - 2220