A triple-target reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid and accurate detection of SARS-CoV-2 virus

被引:5
|
作者
Zhang, Cong [1 ]
Lv, Ji [1 ]
Cao, Yanan [1 ]
Yao, Xiaowei [1 ]
Yin, Mingzhu [1 ]
Li, Shuiqing [1 ]
Zheng, Junping [1 ]
Liu, Hongtao [1 ]
机构
[1] Hubei Univ Chinese Med, Coll Basic Med, Huangjiahu West Rd 16, Wuhan 430065, Peoples R China
关键词
COVID-19; SARS-CoV-2; LAMP; Multi; -target; Colorimetry;
D O I
10.1016/j.aca.2023.341146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The spreading of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) across the world has impacted people's health and lives worldwide in recent years. Rapid and accurate diagnosis is crucial for curbing the pandemic of coronavirus disease 2019 (COVID-19). Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has great potential for SARS-CoV-2 detection but fails to completely replace conventional PCR due to the high false-positive rate (FPR). We proposed a triple-target RT-LAMP method for dual-signal, sensitive, and simultaneous detection of conserved genes of SARS-CoV-2. Multiple LAMP primer sets were designed for N, E, and M genes and their amplification efficacy were screened. Then, using artificial plasmids and RNA, the optimal primer set for each gene was examined on specificity, sensitivity, and detection range. The RT-LAMP initiated by these primer sets exhibited better specificity and sensitivity than that of RT-qPCR, and the tripletarget RT-LAMP could determine different variants of SARS-CoV-2. By testing 78 artificial RNA samples, the total FPR of triple-target RT-LAMP was eliminated compared with that of mono-target RT-LAMP. The tripletarget RT-LAMP method precisely identified throat swab specimens through colorimetry and fluorescent signals within 60 min, and the limit of detection (LOD) was as low as 187 copies/reaction. In the future, the tripletarget RT-LAMP can be applied to in-field and on-site diagnosis of symptomatic and asymptomatic virus carriers.
引用
收藏
页数:10
相关论文
共 50 条
  • [22] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) primer design based on Indonesia SARS-CoV-2 RNA sequence
    Irsyad Ibadurrahman
    Journal of Genetic Engineering and Biotechnology, 21
  • [23] Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Lai, Meng Yee
    Bukhari, Fatma Diyana Mohd
    Zulkefli, Nur Zulaikha
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Soh, Tuan Suhaila Tuan
    Hassan, Afifah Haji
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Suppiah, Jeyanthi
    Thayan, Ravindran
    Isa, Mohd Khairi Mat
    Wahid, Nur Zafirah Abdul
    Lau, Yee Ling
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [24] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) primer design based on Indonesia SARS-CoV-2 RNA sequence
    Ibadurrahman, Irsyad
    Suryani
    Desriani
    JOURNAL OF GENETIC ENGINEERING AND BIOTECHNOLOGY, 2023, 21 (01)
  • [25] Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Meng Yee Lai
    Fatma Diyana Mohd Bukhari
    Nur Zulaikha Zulkefli
    Ilyiana Ismail
    Nur Izati Mustapa
    Tuan Suhaila Tuan Soh
    Afifah Haji Hassan
    Kalaiarasu M. Peariasamy
    Yee Leng Lee
    Jeyanthi Suppiah
    Ravindran Thayan
    Mohd Khairi Mat Isa
    Nur Zafirah Abdul Wahid
    Yee Ling Lau
    BMC Infectious Diseases, 22
  • [26] Rapid detection of Banna virus by reverse transcription-loop -mediated isothermal amplification (RT-LAMP)
    Xia, Han
    Zhao, Na
    Zhao, Lu
    Wang, Yujuan
    Zhao, Wang
    Yuan, Zhiming
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2019, 78 : 93 - 98
  • [27] Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting
    Nuchnoi, Pornlada
    Piromtong, Pakorn
    Siribal, Saranya
    Anansilp, Korrarit
    Thichanpiang, Peeradech
    Okada, Pilailuk Akkapaiboon
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2023, 128 : 285 - 289
  • [28] Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
    Curtis, Kelly A.
    Rudolph, Donna L.
    Owen, S. Michele
    JOURNAL OF VIROLOGICAL METHODS, 2008, 151 (02) : 264 - 270
  • [29] Rapid and sensitive detection of porcine torovirus by a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Liu, Xiaowan
    Zhou, Yuancheng
    Yang, Fan
    Liu, Pengjuan
    Cai, Yuhan
    Huang, Jianbo
    Zhu, Ling
    Xu, Zhiwen
    JOURNAL OF VIROLOGICAL METHODS, 2016, 228 : 103 - 107
  • [30] Detection of enterovirus 71 using reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Wang, Xiang
    Zhu, Jun-ping
    Zhang, Qian
    Xu, Zi-gang
    Zhang, Fang
    Zhao, Zhi-hui
    Zheng, Wen-zhi
    Zheng, Li-shu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 330 - 334