Validation of a handheld single-lead ECG algorithm for atrial fibrillation detection after coronary revascularization

被引:2
|
作者
Skroder, Sofia [1 ,2 ]
Wickbom, Anders [2 ,3 ]
Bjorkenheim, Anna [2 ,4 ]
Ahlsson, Anders [5 ]
Poci, Dritan [2 ,6 ,7 ]
Fengsrud, Espen [2 ,4 ]
机构
[1] Ctr Clin Res & Educ, Karlstad, Region Varmland, Sweden
[2] Orebro Univ, Fac Med & Hlth, Sch Med Sci, Orebro, Sweden
[3] Orebro Univ Hosp, Dept Cardiothorac & Vasc Surg, Orebro, Sweden
[4] Orebro Univ Hosp, Dept Cardiol, Orebro, Sweden
[5] Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden
[6] Sahlgrens Univ Hosp, Dept Clin Physiol, Gothenburg, Sweden
[7] Univ Gothenburg, Inst Med, Sahlgrenska Acad, Dept Mol & Clin Med, Gothenburg, Sweden
来源
关键词
arrhythmia; atrial fibrillation; cardiac electrophysiology; coronary artery disease; coronary revascularization; electrocardiography; STROKE;
D O I
10.1111/pace.14745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial fibrillation (AF) is a rapidly increasing global public health concern entailing a high risk for ischemic stroke that can largely be avoided with anticoagulation therapy. AF is often underdiagnosed and there is a need for a reliable method of detection in individuals with additional risk factors for stroke such as coronary artery disease. We aimed to validate an automatic rhythm interpretation algorithm in thumb ECG in subjects with recent coronary revascularization. MethodsThumb ECG, a patient-operated handheld single-lead ECG recording device with an automatic interpretation algorithm, was performed three times daily for a month after coronary revascularization and 2-week periods 3, 12, and 24 months post-procedure. The detection of AF by the automatic algorithm on subject and single-strip ECG level was compared to manual interpretation. Results48,308 of 30 s thumb ECG recordings from 255 subjects (mean 212 +/- 3.5 recordings per subject) were retrieved from a database (AF 47 subjects/655 recordings; non-AF 208 subjects/47,653 recordings). The algorithm sensitivity at subject level was 100%, specificity 11.2%, positive predictive value (PPV) 20.2%, and negative predictive value (NPV) 100%. At the single-strip ECG level, sensitivity was 87.6%, specificity 94.0%, PPV 16.8%, and NPV 99.8%. The most common reasons for false positive results were technical disturbance and frequent ectopic beats. ConclusionsThe automatic interpretation algorithm in a handheld thumb ECG device can rule out AF in patients recently undergoing coronary revascularization with high accuracy, but manual confirmation is needed to confirm the diagnose of AF because of high false positive rates.
引用
收藏
页码:782 / 787
页数:6
相关论文
共 50 条
  • [21] Validation of Adhesive Single-Lead ECG Device Compared with Holter Monitoring among Non-Atrial Fibrillation Patients
    Kwon, Soonil
    Lee, So-Ryoung
    Choi, Eue-Keun
    Ahn, Hyo-Jeong
    Song, Hee-Seok
    Lee, Young-Shin
    Oh, Seil
    SENSORS, 2021, 21 (09)
  • [22] Prediction of atrial fibrillation from at-home single-lead ECG signals without arrhythmias
    Matteo Gadaleta
    Patrick Harrington
    Eric Barnhill
    Evangelos Hytopoulos
    Mintu P. Turakhia
    Steven R. Steinhubl
    Giorgio Quer
    npj Digital Medicine, 6
  • [23] A Novel Recurrent Neural Network Architecture for Classification of Atrial Fibrillation Using Single-lead ECG
    Banerjee, Rohan
    Ghose, Avik
    Khandelwal, Sundeep
    2019 27TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2019,
  • [24] Explaining the Deep Learning Black Box by Identifying Segments of the Single-Lead ECG Signal Used for Detection of Atrial Fibrillation
    Ivaturi, Praharsh
    Gadaleta, Matteo
    Pandey, Amitabh C.
    Pazzani, Michael
    Steinhubl, Steven R.
    Quer, Giorgio
    CIRCULATION, 2020, 142
  • [25] Prediction of atrial fibrillation from at-home single-lead ECG signals without arrhythmias
    Gadaleta, Matteo
    Harrington, Patrick
    Barnhill, Eric
    Hytopoulos, Evangelos
    Turakhia, Mintu P.
    Steinhubl, Steven R.
    Quer, Giorgio
    NPJ DIGITAL MEDICINE, 2023, 6 (01)
  • [26] Accuracy of a smartwatch based single-lead electrocardiogram device in detection of atrial fibrillation
    Rajakariar, Kevin
    Koshy, Anoop N.
    Sajeev, Jithin K.
    Nair, Sachin
    Roberts, Louise
    Teh, Andrew W.
    HEART, 2020, 106 (09) : 665 - 670
  • [27] Efficient Detection of Atrial Fibrillation and Congestive Heart Failure in Single-Lead Devices
    Moorman, Randall
    Xiao, Yuping
    Lake, Douglas
    CIRCULATION, 2008, 118 (18) : S680 - S680
  • [28] A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG
    Varon, Carolina
    Caicedo, Alexander
    Testelmans, Dries
    Buyse, Bertien
    Van Huffel, Sabine
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2269 - 2278
  • [29] Screening for Atrial Fibrillation (AF) by handheld single-lead ECG and risk of all-cause mortality stratified by non-AF cardiovascular disease
    Sun, W.
    Yan, B.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [30] Screening for Atrial Fibrillation (AF) by handheld single-lead ECG and risk of all-cause mortality stratified by non-AF cardiovascular disease
    Sun, W.
    Yan, B.
    EUROPEAN HEART JOURNAL, 2024, 45