Energy-efficient indirect evaporative cooler design framework: An experimental and numerical study

被引:19
|
作者
Jamil, Muhammad Ahmad [1 ]
Shahzad, Muhammad Wakil [1 ]
Bin Xu, Ben [1 ]
Imran, Muhammad [2 ]
Ng, Kim Choon [3 ]
Zubair, Syed M. [4 ]
Markides, Christos N. [5 ]
Worek, William M. [6 ]
机构
[1] Northumbria Univ, Mech & Construct Engn Dept, Newcastle Upon Tyne, Tyne & Wear, England
[2] Aston Univ, Dept Mech Biomed & Design Engn, Birmingham B4 7ET, W Midlands, England
[3] King Abdullah Univ Sci & Technol, Water Desalinat & Reuse Ctr, Thuwal, Saudi Arabia
[4] King Fahd Univ Petr & Minerals, Mech Engn Dept, Dhahran, Saudi Arabia
[5] Imperial Coll London, Dept Chem Engn, Clean Energy Proc CEP Lab, London SW7 2AZ, England
[6] Argonne Natl Lab, Bldg & Ind Technol Energy Syst & Infrastruct Anal, Lemont, IL 60439 USA
基金
英国工程与自然科学研究理事会;
关键词
Novel indirect evaporative cooler; Heat transfer coefficient correlation; Sustainable cooling; Experiments; HEAT-TRANSFER ENHANCEMENT; AIR-CONDITIONING SYSTEM; COUNTER-FLOW; COOLING SYSTEM; M-CYCLE; INTEGRATED-SYSTEM; MASS EXCHANGER; PERFORMANCE; CONSUMPTION; SUMMER;
D O I
10.1016/j.enconman.2023.117377
中图分类号
O414.1 [热力学];
学科分类号
摘要
A remarkable surge in cooling demand is observed in the last decades. Currently, the cooling market is dominated by mechanical vapor compression chillers which are energy intensive and use harmful chemical refrigerants. Therefore, the current focus of the current research in cooling is the development of unconventional, sustainable cooling systems. In this regard, indirect evaporative coolers have shown significant potential (particularly under hot-dry climates) with high energy efficiency, low cost, water-based sustainable operation, and benign emissions. However, these systems are in the development stage and have not yet been fully commercialized because of certain design challenges. An innovative indirect evaporative cooler is proposed, fabricated, and experimentally tested in this study. Particularly, the study is focused on the development of heat transfer coefficient correlation for the system for commercial-scale design and expansion. This is because the earlier available correlation is based on simple airflow between parallel plates assumption and does not incorporate the effect of the evaporative potential of the system resulting in under/over-estimation of the heat transfer characteristics. The results showed that the proposed system achieved a temperature drop of 20 degrees C, a cooling capacity of around 180 W, and an overall heat transfer coefficient of up to 30 W/m2K. Moreover, the study presents an experiment-regression-based heat transfer coefficient correlation that satisfactorily captures the effect of outdoor air temperature and airflow rate ratio which are critical in the design of evaporative coolers. The proposed correlation showed a high (& PLUSMN;5%) with experimental data thus making it suitable for the future design of IEC systems over assorted operating scenarios.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Experimental Study on the Thermal Performances of a Tube-Type Indirect Evaporative Cooler
    Sun, Tiezhu
    Sun, Huan
    Tang, Tingzheng
    Yan, Yongcheng
    Li, Peixuan
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2023, 19 (10): : 2519 - 2531
  • [22] Experimental Study on the Performance of an Air Conditioning Unit with a Baffled Indirect Evaporative Cooler
    Kim, Seong-Bhin
    Moon, Kwang-Am
    Choi, Hwi-Ung
    Choi, Kwang-Hwan
    ENERGIES, 2024, 17 (13)
  • [23] Experimental and numerical investigation of the temperature and humidity distribution inside the channels for a regenerative indirect evaporative cooler
    Xu, Peng
    Mu, Xin
    Chen, Hongbing
    Ma, Xuxian
    Zhao, Xudong
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [24] Experimental study of the optimal design and performance of a mixed-flow dew-point indirect evaporative cooler
    Urso, Alessandra
    Velasco-Gomez, Eloy
    Tejero-Gonzalez, Ana
    Andres-Chicote, Manuel
    Nocera, Francesco
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [25] Optimisation of a desiccant cooling system design with indirect evaporative cooler
    Goldsworthy, M.
    White, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01): : 148 - 158
  • [26] Experimental study of plant fiber-polymer composite for indirect evaporative cooler application
    Chen, Yi
    Huang, Xiang
    Sun, Tiezhu
    Chu, Junjie
    APPLIED THERMAL ENGINEERING, 2021, 199
  • [27] Energy and exergy study on indirect evaporative cooler used in exhaust air heat recovery
    Li, Wuyan
    Li, Yongcai
    Shi, Wenxing
    Lu, Jun
    ENERGY, 2021, 235
  • [28] Numerical study and optimization of the cross-flow Maisotsenko cycle indirect evaporative air cooler
    Pandelidis, Demis
    Anisimov, Sergey
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 103 : 1029 - 1041
  • [29] Numerical study on parametric correlations and regional applicability of a cross-flow indirect evaporative cooler
    Gao, Wenxue
    Yang, Mingchang
    Wang, Yan
    Yang, Lin
    Miao, Qingwei
    Yan, Rongsong
    Hu, Yingjie
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [30] Numerical study and optimization of the combined indirect evaporative air cooler for air-conditioning systems
    Anisimov, Sergey
    Pandelidis, Demis
    Danielewicz, Jan
    ENERGY, 2015, 80 : 452 - 464