Long-term safety and efficacy of left atrial appendage closure in patients with small appendage orifices measured with transesophageal echocardiography

被引:1
|
作者
Wang, Binhao [1 ,2 ]
Wang, Zhao [3 ]
Chu, Huimin [1 ,2 ]
He, Bin [1 ,2 ]
Fu, Guohua [1 ,2 ]
Feng, Mingjun [1 ,2 ]
Du, Xianfeng [1 ,2 ]
Liu, Jing [1 ,2 ]
Yu, Yibo [1 ,2 ]
机构
[1] Ningbo First Hosp, Arrhythmia Ctr, Liuting Rd 59, Ningbo 315010, Zhejiang, Peoples R China
[2] Key Lab Precis Med Atherosclerot Dis Zhejiang Pro, Ningbo, Peoples R China
[3] Ningbo First Hosp, Dept Ultrasonog, Ningbo, Peoples R China
关键词
atrial fibrillation; left atrial appendage closure; stroke; Watchman; WATCHMAN DEVICE; EMBOLIC PROTECTION; FIBRILLATION; EXPERIENCE; WARFARIN; OUTCOMES; SYSTEM;
D O I
10.1002/clc.23950
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The Watchman device is the most widely used occluder but is indicated in atrial fibrillation (AF) patients with a maximal left atrial appendage (LAA) orifice diameter between 17 and 31 mm. We aimed to compare the long-term safety and efficacy of left atrial appendage closure (LAAC) between patients with a small LAA (<17 mm) and those with an indicated LAA (17-31 mm) measured by transesophageal echocardiography (TEE). Methods A total of 369 AF patients treated with LAAC between March 2015 and February 2019 were included and divided into two groups based on the maximal LAA orifice diameter measured by TEE: small LAA group (n = 22) and indicated LAA group (n = 347). Periprocedural complications and long-term clinical outcomes were compared. Results The Watchman device was successfully implanted in all patients. Mean device compression was higher in the small LAA group. Four patients (1.2%) in the indicated LAA group experienced pericardial effusion, and none experienced pericardial effusion in the small LAA group. Device-related thrombus was detected in one (4.5%) patient in the small LAA group and five (1.4%) in the indicated LAA group (p = .310). After a mean follow-up period of 4.1 +/- 1.6 years, one patient in the small LAA group (4.5%; 1.1/100 person-years) and four in the indicated LAA group (1.2%; 0.3/100 person-years) suffered an ischemic stroke (p = .266). Conclusions The safety and efficacy of LAAC with the Watchman device were comparable between patients with small and indicated LAA orifice diameters measured by TEE.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 50 条
  • [41] Safety and Efficacy of Transcatheter Left Atrial Appendage Closure for Stroke Prevention in Patients with Atrial Fibrillation
    Price, Matthew J.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2018, 60 (4-5) : 542 - 549
  • [42] Percutaneous left atrial appendage closure in patients with persistent left atrial appendage thrombus
    Del Marmol, G.
    Dourte, E.
    Ceulemans, A.
    Lepiece, C.
    Aminian, A.
    De Meester, A.
    ACTA CARDIOLOGICA, 2019, 74 (05) : 450 - 451
  • [43] Percutaneous closure of the left atrial appendage: The value of real time 3D transesophageal echocardiography and the intraoperative change in the size of the left atrial appendage
    Zhang, Lizi
    Cong, Tao
    Liu, Ansheng
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (03): : 537 - 545
  • [44] Assessment of transesophageal echocardiography to describe left atrial appendage morphology
    Morello, M.
    Anselmino, M. A.
    Jorfida, M.
    Gili, S.
    Perversi, J.
    Frea, S.
    Marra, W. Grosso
    Faletti, R.
    Righi, D.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2014, 35 : 281 - 281
  • [45] Left Atrial Appendage Occlusion Guided Only by Transesophageal Echocardiography
    Zhao, Jinlong
    Li, Feng
    Zhang, Yueli
    Zhuang, Zhongyun
    Wang, Man
    Fu, Liang
    Ni, Yinkai
    Lu, Zhexin
    Chen, Zonghui
    Zhang, Cheng
    CARDIOLOGY RESEARCH AND PRACTICE, 2019, 2019
  • [46] SAFETY OF LEFT ATRIAL APPENDAGE CLOSURE IN HEART FAILURE PATIENTS
    Das, Subrat
    Wu, Lingling
    Mehta, Davendra
    Suri, Ranjit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 349 - 349
  • [47] Safety of left atrial appendage closure in heart failure patients
    Das, Subrat
    Lorente-Ros, Marta
    Wu, Lingling
    Mehta, Davendra
    Suri, Ranjit
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (12) : 2578 - 2584
  • [48] Left atrial appendage orifice dimensions in Japanese atrial fibrillation population measured by multiplane transesophageal echocardiography
    Miyoshi, Miho
    Watanabe, Nozomi
    Fukuda, Tomoko
    Nishino, Shun
    Kimura, Toshiyuki
    Furugen, Makoto
    Ashikaga, Keiichi
    Takahashi, Naohiko
    Shibata, Yoshisato
    JOURNAL OF ECHOCARDIOGRAPHY, 2022, 20 (04) : 201 - 207
  • [49] Left atrial appendage orifice dimensions in Japanese atrial fibrillation population measured by multiplane transesophageal echocardiography
    Miho Miyoshi
    Nozomi Watanabe
    Tomoko Fukuda
    Shun Nishino
    Toshiyuki Kimura
    Makoto Furugen
    Keiichi Ashikaga
    Naohiko Takahashi
    Yoshisato Shibata
    Journal of Echocardiography, 2022, 20 : 201 - 207
  • [50] RADIATION DOSES TO PHYSICIANS PERFORMING TRANSESOPHAGEAL ECHOCARDIOGRAPHY DURING PERCUTANEOUS LEFT ATRIAL APPENDAGE CLOSURE
    McNamara, Michael W.
    Decker, Jeffrey
    Vanoosterhout, Stacie
    Mulder, Abbey
    Ten Brock, Taylor
    Berkompas, Duane
    Dahu, Musa
    Parker, Jessica
    Madder, Ryan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1089 - 1089