Long-term safety and efficacy of left atrial appendage closure in patients with small appendage orifices measured with transesophageal echocardiography

被引:1
|
作者
Wang, Binhao [1 ,2 ]
Wang, Zhao [3 ]
Chu, Huimin [1 ,2 ]
He, Bin [1 ,2 ]
Fu, Guohua [1 ,2 ]
Feng, Mingjun [1 ,2 ]
Du, Xianfeng [1 ,2 ]
Liu, Jing [1 ,2 ]
Yu, Yibo [1 ,2 ]
机构
[1] Ningbo First Hosp, Arrhythmia Ctr, Liuting Rd 59, Ningbo 315010, Zhejiang, Peoples R China
[2] Key Lab Precis Med Atherosclerot Dis Zhejiang Pro, Ningbo, Peoples R China
[3] Ningbo First Hosp, Dept Ultrasonog, Ningbo, Peoples R China
关键词
atrial fibrillation; left atrial appendage closure; stroke; Watchman; WATCHMAN DEVICE; EMBOLIC PROTECTION; FIBRILLATION; EXPERIENCE; WARFARIN; OUTCOMES; SYSTEM;
D O I
10.1002/clc.23950
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The Watchman device is the most widely used occluder but is indicated in atrial fibrillation (AF) patients with a maximal left atrial appendage (LAA) orifice diameter between 17 and 31 mm. We aimed to compare the long-term safety and efficacy of left atrial appendage closure (LAAC) between patients with a small LAA (<17 mm) and those with an indicated LAA (17-31 mm) measured by transesophageal echocardiography (TEE). Methods A total of 369 AF patients treated with LAAC between March 2015 and February 2019 were included and divided into two groups based on the maximal LAA orifice diameter measured by TEE: small LAA group (n = 22) and indicated LAA group (n = 347). Periprocedural complications and long-term clinical outcomes were compared. Results The Watchman device was successfully implanted in all patients. Mean device compression was higher in the small LAA group. Four patients (1.2%) in the indicated LAA group experienced pericardial effusion, and none experienced pericardial effusion in the small LAA group. Device-related thrombus was detected in one (4.5%) patient in the small LAA group and five (1.4%) in the indicated LAA group (p = .310). After a mean follow-up period of 4.1 +/- 1.6 years, one patient in the small LAA group (4.5%; 1.1/100 person-years) and four in the indicated LAA group (1.2%; 0.3/100 person-years) suffered an ischemic stroke (p = .266). Conclusions The safety and efficacy of LAAC with the Watchman device were comparable between patients with small and indicated LAA orifice diameters measured by TEE.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 50 条
  • [1] Short-term safety and efficacy of left atrial appendage closure with the WATCHMAN device in patients with small left atrial appendage ostia
    Venkataraman, Ganesh
    Strickberger, S. Adam
    Doshi, Shephal
    Ellis, Christopher R.
    Lakkireddy, Dhanunjaya
    Whalen, S. Patrick
    Cuoco, Frank
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (01) : 17 - 21
  • [2] Long-term transesophageal echocardiography follow-up after percutaneous left atrial appendage closure
    Staubach, Stephan
    Schlatterbeck, Leonhard
    Moertl, Moritz
    Strohm, Henning
    Hoppmann, Petra
    Laugwitz, Karl-Ludwig
    Mudra, Harald
    Ledwoch, Jakob
    HEART RHYTHM, 2020, 17 (05) : 728 - 733
  • [3] Long-Term Safety and Efficacy of Percutaneous Left Atrial Appendage Closure with the LAmbre Device
    Wang, Guangji
    Kong, Bin
    Liu, Yu
    Huang, He
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2020, 2020
  • [4] Long-Term Safety and Efficacy in Continued Access Left Atrial Appendage Closure Registries
    Holmes, David R., Jr.
    Reddy, Vivek Y.
    Gordon, Nicole T.
    Delurgio, David
    Doshi, Shephal K.
    Desai, Amish J.
    Stone, James E., Jr.
    Kar, Saibal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) : 2878 - 2889
  • [5] Intraoperative transesophageal echocardiography is essential for left atrial appendage closure
    Guner, Ezgi G.
    corekcioglu, Busra
    Ulutas, Ahmet E.
    Kalcik, Macit
    Guner, Ahmet
    Erturk, Mehmet
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (01) : 412 - 413
  • [6] A novel Morphological Classification for left atrial appendage by transesophageal echocardiography and its impact in left atrial appendage closure
    Qiao, Zhiqing
    Ge, Heng
    Jiang, Lisheng
    Li, Zheng
    Wang, Xinhua
    Shen, Xuedong
    He, Ben
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C201 - C201
  • [7] Safety and efficacy of catheter-based left atrial appendage closure in patients with contraindications for long-term anticoagulation
    Seidel, Adrian
    Parwani, Abdul S.
    Krackhardt, Florian
    Huemer, Martin
    Attanasio, Philipp
    Haverkamp, Wilhelm
    Pieske, Burkert
    Boldt, Leif-Hendrik
    MINERVA CARDIOANGIOLOGICA, 2017, 65 (06): : 545 - 552
  • [8] Left atrial appendage closure in patients with left atrial appendage thrombus guided by intracardiac echocardiography
    Wang, Binhao
    Chu, Huimin
    Wang, Zhao
    Fu, Guohua
    Yu, Yibo
    Feng, Mingjun
    Du, Xianfeng
    HEART RHYTHM, 2024, 21 (06) : 812 - 818
  • [9] Reply: Intraoperative transesophageal echocardiography is essential for left atrial appendage closure
    Shen, Ming
    Liu, Gang
    Wei, Shixiong
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (09) : 3458 - 3458
  • [10] Transnasal Transesophageal Echocardiography Guidance for Percutaneous Left Atrial Appendage Closure
    Wang, Bin
    Zhang, Li
    Sun, Wei
    He, Lin
    Wang, Xinfang
    Lv, Qing
    Li, Yuman
    Xie, Mingxing
    ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E161 - E164