CORONARY ANGIOGRAPHY WITH DUAL SOURCE COMPUTED TOMOGRAPHY:INITIAL EXPERIENCE

被引:3
|
作者
Zhu-hua Zhang1
机构
关键词
computed tomography; coronary angiography; coronary heart disease;
D O I
暂无
中图分类号
R816.2 [心脏血管系];
学科分类号
1001 ; 100105 ; 100207 ; 100602 ;
摘要
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [21] Dual-source computed tomography angiography in patients after bypass grafting - comparison with invasive coronary angiography
    Kepka, Cezary
    Opolski, Maksymilian P.
    Kruk, Mariusz
    Pregowski, Jerzy
    Michalowska, Ilona
    Demkow, Marcin
    Witkowski, Adam
    Ruzyllo, Witold
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2010, 6 (01): : 12 - 20
  • [22] Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual-Source Computed Tomography
    Sagsoz, M. Erdem
    Bayraktutan, Ummugulsum
    Ogul, Hayri
    Kantarci, Mecit
    EURASIAN JOURNAL OF MEDICINE, 2013, 45 (01): : 43 - 46
  • [23] Coronary computed tomography angiography using 128-slice dual-source computed tomography in patients with severe calcification
    Suguru Sato
    Yosuke Horii
    Norihiko Yoshimura
    Takuya Yagi
    Hidefumi Aoyama
    Japanese Journal of Radiology, 2017, 35 : 432 - 439
  • [24] Coronary computed tomography angiography using 128-slice dual-source computed tomography in patients with severe calcification
    Sato, Suguru
    Horii, Yosuke
    Yoshimura, Norihiko
    Yagi, Takuya
    Aoyama, Hidefumi
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (08) : 432 - 439
  • [25] Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography
    Kirchhoff, S.
    Herzog, P.
    Johnson, T.
    Boehm, H.
    Nikolaou, K.
    Reiser, M. F.
    Becker, C. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : E182 - E186
  • [26] New approach to noninvasive coronary angiography by multidetector computed tomography:: Initial experience using gadolinium
    Carrascosa, Patricia
    Merletti, Pablo Garcia
    Capunay, Carlos
    Goldsmit, Alejandro
    Bettinotti, Marcelo
    Carrascosa, Jorge
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (03) : 441 - 443
  • [27] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [28] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):
  • [29] Dual-source Computed Tomography Angiography for the Assessment of In-stent Restenosis in Coronary Arteries
    Pugliese, F.
    Alberghina, F.
    Weustink, A. C.
    Otsuka, M.
    Mollet, N. R.
    de Feyter, P. J.
    Krestin, G. P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [30] Noninvasive Coronary Angiography Using Dual-Source Computed Tomography in Patients With Atrial Fibrillation
    Rist, Carsten
    Johnson, Thorsten R.
    Mueller-Starck, Jens
    Arnoldi, Elisabeth
    Saam, Tobias
    Becker, Alexander
    Leber, Alexander W.
    Wintersperger, Bernd J.
    Becker, Christoph R.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    INVESTIGATIVE RADIOLOGY, 2009, 44 (03) : 159 - 167