Randomized trial in malignant biliary obstruction:Plastic vs partially covered metal stents

被引:7
|
作者
Peter L Moses [1 ]
Khalid M AlNaamani [2 ,3 ]
Alan N Barkun [2 ,3 ,4 ]
Stuart R Gordon [5 ]
Roger D Mitty [6 ]
M Stanley Branch [7 ]
Thomas E Kowalski [8 ]
Myriam Martel [2 ,3 ]
Viviane Adam [2 ,3 ]
机构
[1] Division of Gastroenterology and Hepatology, University of Vermont
[2] Division of Gastroenterology, McGill University Health Center
[3] McGill University
[4] Department of Epidemiology and Biostatistics and Occupational Health, McGill University Health Center
[5] Division of Gastroenterology and Hepatology, Dartmouth Hitchcock Medical Center, Lebanon
[6] Division of Gastroenterology, Tufts University School of Medicine, Boston
[7] Division of Gastroenterology, Duke University Medical Center, Durham
[8] Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital
关键词
Randomized; Biliary; Obstruction; Stent; Plastic; Metal; Palliative; Common bile duct;
D O I
暂无
中图分类号
R735.8 [胆囊、胆道肿瘤];
学科分类号
100214 ;
摘要
AIM:To compare efficacy and complications of par-tially covered self-expandable metal stent(pcSEMS)to plastic stent(PS)in patients treated for malignant,infrahilar biliary obstruction.METHODS:Multicenter prospective randomized clinical trial with treatment allocation to a pcWallstent(SEMS)or a 10 French PS.Palliative patients aged≥18,for infrahilar malignant biliary obstruction and a Karnofsky performance scale index>60%from 6 participating North American university centers.Primary endpoint was time to stent failure,with secondary outcomes of death,adverse events,Karnofsky performance score and short-form-36 scale administered on a three-monthly basis for up to 2 years.Survival analyses were performed for stent failure and death,with Cox proportional hazards regression models to determine significant predictive characteristics.RESULTS:Eighty-five patients were accrued over 37mo,42 were randomized to the SEMS group and 83patients were available for analyses.Time to stent failure was 385.3±52.5 d in the SEMS and 153.3±19.8 d in the PS group,P=0.006.Time to death did not differ between groups(192.3±23.4 d for SEMS vs211.5±28.0 d for PS,P=0.70).The only significant predictor was treatment allocation,relating to the time to stent failure(P=0.01).Amongst other measured outcomes,only cholangitis differed,being more common in the PS group(4.9%vs 24.5%,P=0.029).The small number of patients in follow-up limits longitudinal assessments of performance and quality of life.From an initially planned 120 patients,only 85 patients were recruited.CONCLUSION:Partially covered SEMS result in a longer duration till stent failure without increased complication rates,yet without accompanying measurable benefits in survival,performance,or quality of life.
引用
收藏
页码:8638 / 8646
页数:9
相关论文
共 50 条
  • [21] Nitinol versus steel partially covered self-expandable metal stent for malignant distal biliary obstruction: a randomized trial
    Soderlund, Claes
    Linder, Stefan
    Bergenzaun, Per E.
    Grape, Tomas
    Hakansson, Hans-Olof
    Kilander, Anders
    Lindell, Gert
    Ljungman, Martin
    Ohlin, Bo
    Nielsen, Jorgen
    Rudberg, Claes
    Stotzer, Per-Ove
    Svartholm, Erik
    Toth, Ervin
    Frozanpor, Farshad
    ENDOSCOPY, 2014, 46 (11) : 941 - 948
  • [22] Comparison of three different stents (plastic and metal) for malignant biliary obstruction
    Rosenberg, PM
    Brugge, WR
    Schapiro, RH
    Kelsey, PB
    GASTROINTESTINAL ENDOSCOPY, 1999, 49 (04) : AB236 - AB236
  • [23] METAL STENTS FOR MALIGNANT BILIARY OBSTRUCTION
    LAMERIS, JS
    STOKER, J
    DIGESTIVE DISEASES, 1994, 12 (03) : 161 - 169
  • [24] Self-expandable metal stents versus plastic stents for malignant biliary obstruction
    Almadi, Majid A.
    Barkun, Alan
    Martel, Myriam
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (04) : 852 - 853
  • [25] Paclitaxel Eluting Covered Metal Stents Versus Covered Metal Stents for Malignant Biliary Obstruction; Prospective Comparative Pilot Study
    Song, Tae Jun
    Lee, Sang Soo
    Eum, Junbum
    Moon, Sung-Hoon
    Park, Do Hyun
    Seo, Dong Wan
    Lee, Sung Koo
    Kim, Myung-Hwan
    Choi, Eun Kwang
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB118 - AB118
  • [26] A randomized multicenter trial comparing plastic to covered metal stems for the palliation of lower malignant biliary obstruction: A planned interim analysis
    Moses, PL
    Barkun, AN
    Gordon, SR
    Mitty, RD
    Branch, MS
    Kowalski, TE
    GASTROINTESTINAL ENDOSCOPY, 2004, 59 (05) : AB188 - AB188
  • [27] Uncovered vs Fully Covered Self-Expandable Metal Stents for the Management of Distal Malignant Biliary Obstruction
    Ghazi, Rabih
    Mahmoud, Tala
    Martin, John A.
    Law, Ryan
    Levy, Michael J.
    Abu Dayyeh, Barham K.
    Storm, Andrew C.
    Petersen, Bret T.
    Chandrasekhara, Vinay
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2021, 116 : S30 - S30
  • [28] Partially covered self-expandable metal stents versus polyethylene stents for malignant biliary obstruction: A cost-effectiveness analysis
    Barkun, Alan N.
    Adam, Viviane
    Martel, Myriam
    AlNaamani, Khalid
    Moses, Peter L.
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 29 (07): : 377 - 383
  • [29] RANDOMIZED TRIAL OF SELF-EXPANDING METAL STENTS VERSUS POLYETHYLENE STENTS FOR DISTAL MALIGNANT BILIARY OBSTRUCTION
    DAVIDS, PHP
    GROEN, AK
    RAUWS, EAJ
    TYTGAT, GNJ
    HUIBREGTSE, K
    LANCET, 1992, 340 (8834-5): : 1488 - 1492
  • [30] A PROSPECTIVE, CONTROLLED, RANDOMIZED TRIAL OF EXPANDABLE METAL STENTS IN MALIGNANT BILIARY OBSTRUCTION - FINAL REPORT
    KNYRIM, K
    WAGNER, HJ
    PAUSCH, J
    VAKIL, N
    GASTROINTESTINAL ENDOSCOPY, 1993, 39 (02) : 321 - 321