1 INTRODUCTIONAnnular pulsed-sieve-plate extraction column is an unique extraction equipment that can beused to ensure critical safety in reprocssing of irradiated nuclear fuel,The study of this kind ofextraction column has been carried out and some results were published in resent years [1—9]. It is known that axial mixing is one of most important parameters effecting column be-
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [41] AXIAL MIXING AND MASS TRANSFER PERFORMANCE OF AN ANNULAR PULSED DISC-AND-DOUGHNUT COLUMN
    Liu, Jian-Quan
    Li, Shao-Wei
    Jing, Shan
    SOLVENT EXTRACTION AND ION EXCHANGE, 2015, 33 (06) : 592 - 606
  • [42] Mechanism Analysis on the Two-Phase Flow Characteristics in Coalescence-Dispersion Pulsed-Sieve-Plate Extraction Columns
    Tang Xiaojin
    Luo Guangsheng
    Wang Jiading
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (23) : 9724 - 9727
  • [43] Investigation of mass transfer performance in an L-shaped pulsed sieve plate extraction column using axial dispersion model
    Rafiei, Vahid
    Safdari, Jaber
    Moradi, Sadegh
    Amani, Pouria
    Mallah, Mohammad H.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 128 : 130 - 145
  • [44] SOLVENT-EXTRACTION CALCULATION MODEL FOR PUREX PROCESS IN PULSED SIEVE PLATE COLUMN
    GONDA, K
    MATSUDA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1986, 23 (10) : 883 - 895
  • [45] Characteristic velocity of drops in a liquid-liquid extraction pulsed sieve plate column
    Hussain, A.A.
    Liang, T.-B.
    Slater, M.J.
    Chemical Engineering Research and Design, 1988, 66 (06) : 541 - 554
  • [46] Numerical analysis of dispersed drop behavior in the pulsed sieve-plate extraction column
    Ohta, M
    Suzuki, M
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1998, 25 (04) : 521 - 530
  • [47] CHARACTERISTIC VELOCITY OF DROPS IN A LIQUID-LIQUID-EXTRACTION PULSED SIEVE PLATE COLUMN
    HUSSAIN, AA
    LIANG, TB
    SLATER, MJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1988, 66 (06): : 541 - 554
  • [48] Mass transfer performance in a coalescence-dispersion pulsed sieve plate extraction column
    Li, HB
    Luo, GS
    Fei, WY
    Wang, JD
    CHEMICAL ENGINEERING JOURNAL, 2000, 78 (2-3) : 225 - 229
  • [49] CFD Simulations of Pulsed Sieve Plate Column: Axial Dispersion in Single-Phase Flow
    Sen, Nirvik
    Singh, K. K.
    Patwardhan, A. W.
    Mukhopadhyay, S.
    Shenoy, K. T.
    SEPARATION SCIENCE AND TECHNOLOGY, 2015, 50 (16) : 2485 - 2495
  • [50] CFD and experimental studies of single phase axial dispersion coefficient in pulsed sieve plate column
    Kolhe, N. S.
    Mirage, Y. H.
    Patwardhan, A. V.
    Rathod, V. K.
    Pandey, N. K.
    Mudali, U. Kamachi
    Natarajan, R.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (10A): : 1909 - 1918