Numerical investigation of airborne transmission of respiratory infections on the subway platform

被引:0
|
作者
Jianjian Wei [1 ,2 ]
Sirui Zhu [1 ,3 ]
Feiwu He [4 ]
Qianfang Guo [5 ]
Xinxin Huang [5 ,6 ]
Jianxiang Yu [5 ]
Lirong Zou [5 ]
Tao Jin [1 ]
Jie Wu [5 ,6 ]
机构
[1] Institute of Refrigeration and Cryogenics/Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Zhejiang University
[2] Center for Balance Architecture, Zhejiang University
[3] The Architectural Design & Research Institute of Zhejiang University Co, Ltd
[4] Guangdong Medicine and Food Consulting and Research Center
[5] Guangdong Provincial Center for Disease Control and Prevention
[6] School of Public Health, Southern Medical University
关键词
D O I
暂无
中图分类号
U231.4 []; R126.4 [公共场所卫生];
学科分类号
0814 ; 082301 ; 100402 ;
摘要
Underground subway platforms are among the world’s busiest public transportation systems, but the airborne transmission mechanism of respiratory infections on these platforms has been rarely studied. Here,computational fluid dynamics(CFD) modeling is used to investigate the airflow patterns and infection risks in an island platform under two common ventilation modes: Mode 1-both sides have air inlets and outlets; Mode 2-air inlets are present at the two sides and outlets are present in the middle.Under the investigated scenario, airflow structure is characterized by the ventilation jet and human thermal plumes. Their interaction with the infector’s breathing jet imposes the front passenger under the highest exposure risk by short-range airborne route, with intake fractions up to 2.57%(oral breathing)or 0.63%(nasal breathing) under Mode 1; oral breathing of the infector may impose higher risks for the front passenger compared with nasal breathing. Pathogen are efficiently diluted as they travel further,in particular to adjacent crowds. The maximum and median value of intake fractions of passengers in adjacent crowds are respectively 0.093% and 0.016%(oral breathing), and 0.073% and 0.014%(nasal breathing) under Mode 1. Compared with Mode 1, the 2nd mode minimizes the interaction of ventilation jet and breathing jet, where the maximum intake fraction is only 0.34%, and the median value in the same crowd and other crowds are reduced by 23–63%. Combining published quanta generation rate data of COVID-19 and influenza infectors, the predicted maximum and median infection risks for passengers in the same crowds are respectively 1.46%–40.23% and 0.038%–1.67% during the 3–10 min waiting period, which are more sensitive to ventilation rate and exposure time compared with return air. This study can provide practical guidance for the prevention of respiratory infections in subway platforms.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [31] Effect of platform subway depth on the presence of Airborne PM2.5, metals, and toxic organic species
    Figueroa-Lara, J. J.
    Murcia-Gonzalez, J. M.
    Garcia-Martinez, R.
    Romero-Romo, M.
    Torres Rodriguez, M.
    Mugica-Alvarez, V.
    JOURNAL OF HAZARDOUS MATERIALS, 2019, 377 : 427 - 436
  • [32] Investigation on the Effect of Platform Height on Smoke Characteristics of Fire Scenarios for Subway Stations
    Xu, Desheng
    Li, Yanfeng
    Li, Junmei
    Zhang, Jin
    Li, Jiaxin
    SUSTAINABILITY, 2021, 13 (19)
  • [33] Prevalence of airborne fungi in Brazil and correlations with respiratory diseases and fungal infections
    Suehara, Marcelo Batista
    da Silva, Mayara Cristina Pinto
    CIENCIA & SAUDE COLETIVA, 2023, 28 (11): : 3289 - 3300
  • [34] Numerical investigation of airborne radars for remote sensing applications
    da Costa, Igor F.
    da Silva, Luis G.
    Mologni, Juliano F.
    Arismar Cerqueira Jr, S.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (06) : 1473 - 1478
  • [35] A Numerical Evaluation of Airborne Transmission Control through Saliva Modification
    Shrestha, Rajendra
    Fontes, Douglas
    Kinzel, Michael
    FLUIDS, 2024, 9 (10)
  • [36] Investigation of bacterial infections of the lower respiratory tract
    Boersma, WG
    Holloway, Y
    CURRENT OPINION IN INFECTIOUS DISEASES, 1996, 9 (02) : 76 - 84
  • [37] Numerical simulation of effect of fresh air rates on transmission of cough droplet transmission in subway passenger cabin
    Li, Hengkui
    Wu, Fan
    Liang, Xifeng
    Dong, Hang
    Li, Xuan
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2024, 55 (05): : 1691 - 1701
  • [38] Etiological investigation of multiple respiratory infections in cats
    Di Martino, B.
    Di Francesco, C. E.
    Meridiani, I.
    Marsilio, F.
    NEW MICROBIOLOGICA, 2007, 30 (04): : 455 - 461
  • [39] Transmission and Control of Respiratory Viral Infections in the Healthcare Setting
    Bonvehi, Pablo E.
    Temporiti, Elena R.
    CURRENT TREATMENT OPTIONS IN INFECTIOUS DISEASES, 2018, 10 (02) : 182 - 196
  • [40] Transmission of respiratory tract infections at mass gathering events
    Petersen, Eskild
    Memish, Ziad A.
    Zumla, Alimuddin
    Al Maani, Amal
    CURRENT OPINION IN PULMONARY MEDICINE, 2020, 26 (03) : 197 - 202