Electrochimical determination of uric acid, xanthine and hypoxanthine by poly(xylitol) modified glassy carbon electrode

被引:1
|
作者
窦志宇 [1 ]
崔丽莉 [1 ]
何兴权 [1 ]
机构
[1] Department of Chemistry and Chemical Engineering, Changchun University of Science and Technology
关键词
xylitol; electropolymerization; uric acid; xanthine; hypoxanthine;
D O I
暂无
中图分类号
O657.1 [电化学分析法];
学科分类号
摘要
The novel covalently modified glassy carbon electrode with poly(xylitol) was prepared using an electropolymerization technique for the simultaneous determination of uric acid(UA), xanthine(XA) and hypoxanthine(HX). This new electrode presents an excellent electrocatalytic activity towards the oxidation of UA, XA and HX by cyclic voltammetry(CV) method. The oxidation peaks of the three compounds were well defined and had enhanced the peak currents. The separation potentials of the oxidation peak potentials for UA-XA and XA-HX were 380 and 370 mV in CV, respectively. Using differential pulse voltammetry(DPV) method, the calibration curves in the ranges of 5-55, 1.3-75.3 and 4-59 μmol/L were obtained for HX, XA and UA, respectively. The lowest detection limits(S/N=3) were 4.5, 0.75 and 3.75 μmol/L for HX, XA and UA, respectively. The practical application of the modified electrode was demonstrated by the determination of UA, XA, HX in human urine samples.
引用
收藏
页码:870 / 876
页数:7
相关论文
共 50 条
  • [21] Simultaneous electrochemical determination of uric acid, xanthine and hypoxanthine based on poly(L-arginine)/graphene composite film modified electrode
    Zhang, Fengyuan
    Wang, Zaihua
    Zhang, Yuzhen
    Zheng, Zhixiang
    Wang, Chunming
    Du, Yongling
    Ye, Weichun
    TALANTA, 2012, 93 : 320 - 325
  • [22] Simple method for simultaneous detection of uric acid, xanthine and hypoxanthine in fish samples using a glassy carbon electrode modified with as commercially received multiwalled carbon nanotubes
    Kumar, Annamalai Senthil
    Shanmugam, Ranganathan
    ANALYTICAL METHODS, 2011, 3 (09) : 2088 - 2094
  • [23] Simultaneous determination of uric acid, dopamine and ascorbic acid based on poly(bromocresol green) modified glassy carbon electrode
    Ouyang, Xiaoqian
    Luo, Liqiang
    Ding, Yaping
    Liu, Bingdi
    Xu, Duo
    Huang, Anquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 748 : 1 - 7
  • [24] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [25] A glassy carbon electrode modified with graphene and poly(acridine red) for sensing uric acid
    Li, Yang
    Ran, Gu
    Yi, Wen Jiao
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 115 - 121
  • [26] A glassy carbon electrode modified with graphene and poly(acridine red) for sensing uric acid
    Yang Li
    Gu Ran
    Wen Jiao Yi
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2012, 178 : 115 - 121
  • [27] Characteristics of a Poly(thionine) Modified Glassy Carbon Electrode and the Detection of Dopamine and Uric acid
    Ahammad, A. J. Saleh
    Li, Xiao-bo
    Rahman, Md. Mahbubur
    Noh, Kwang-Mo
    Lee, Jae-Joon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (06): : 7806 - 7815
  • [28] Simultaneous determination of epinephrine and uric acid at ordered mesoporous carbon modified glassy carbon electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Ding, Yaping
    Zhang, Zhao
    Deng, Dongmei
    Lu, Bo
    ANALYTICAL METHODS, 2012, 4 (08) : 2417 - 2422
  • [29] Examination of performance of glassy carbon paste electrode modified with gold nanoparticle and xanthine oxidase for xanthine and hypoxanthine detection
    Cubukcu, Meliha
    Timur, Suna
    Anik, Uelkue
    TALANTA, 2007, 74 (03) : 434 - 439
  • [30] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502