Performance evaluation of the backprojection filtered (BPF) algorithm in circular fan-beam and cone-beam CT

被引:1
|
作者
LI Liang CHEN Zhi-Qiang ZHANG Li KANG Ke-Jun Department of Engineering Physics
机构
关键词
Cone-beam; PI-line; Backprojection filtered (BPF) algorithm; Hilbert transform;
D O I
暂无
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
In this article we introduce an exact backprojection filtered (BPF) type reconstruction algorithm for cone-beam scans based on Zou and Pan’s work. The algorithm can reconstruct images using only the projection data passing through the parallel PI-line segments in reduced scans. Computer simulations and practical experiments are carried out to evaluate this algorithm. The BPF algorithm has a higher computational efficiency than the famous FDK algorithm. The BPF algorithm is evaluated using the practical CT projection data on a 450 keV X-ray CT system with a flat-panel detector (FPD). From the practical experiments, we get the spatial resolution of this CT system. The algo- rithm could achieve the spatial resolution of 2.4 lp/mm and satisfies the practical applications in industrial CT inspec- tion.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 50 条
  • [41] Wavelet filtering algorithm for fan-beam CT
    Zhao, SY
    Wang, G
    Hsieh, J
    ELECTRONICS LETTERS, 1998, 34 (25) : 2395 - 2396
  • [42] Comparison of fan-beam, cone-beam and spiral scan reconstruction for x-ray micro-CT
    Sasov, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 711 - 718
  • [43] Exact fan-beam reconstruction via ramp-filtered backprojection and local compensation
    Chen, GH
    Tolakanahalli, R
    Zhuang, TL
    Nett, BE
    Hsieh, J
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1014 - 1024
  • [44] Comparison of fan-beam, cone-beam and spiral scan reconstruction in X-ray micro-CT
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 124 - 131
  • [45] A New Curve-filtered FDK-type Algorithm for Circular Cone-beam CT Reconstruction
    Li, Liang
    Xing, Yuxiang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2243 - 2247
  • [46] A curve-filtered FDK (C-FDK) reconstruction algorithm for circular cone-beam CT
    Li, Liang
    Xing, Yuxiang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (03) : 355 - 371
  • [47] Evaluation of non-helical (circular) fan beam scan with cone-beam reconstruction in 18-slice CT
    Hein, IA
    Taguchi, K
    Mori, I
    Kazama, M
    Silver, MD
    RADIOLOGY, 2002, 225 : 496 - 496
  • [48] Performance Evaluation of Reconstruction with Fan-Beam Algorithm with no Backprojection Weight in Truncated Projection Completion using Linear Prediction
    Sumith, K.
    Narasimhadhan, A. V.
    Rajgopal, Kasi
    2011 IEEE REGION 10 CONFERENCE TENCON 2011, 2011, : 344 - 348
  • [49] Evaluation of a CT to cone-beam CT deformable registration algorithm
    Piper, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S418 - S419
  • [50] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT
    Tang, QL
    Zeng, GSL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3153 - 3170