Performance evaluation of the backprojection filtered (BPF) algorithm in circular fan-beam and cone-beam CT

被引:1
|
作者
LI Liang CHEN Zhi-Qiang ZHANG Li KANG Ke-Jun Department of Engineering Physics
机构
关键词
Cone-beam; PI-line; Backprojection filtered (BPF) algorithm; Hilbert transform;
D O I
暂无
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
In this article we introduce an exact backprojection filtered (BPF) type reconstruction algorithm for cone-beam scans based on Zou and Pan’s work. The algorithm can reconstruct images using only the projection data passing through the parallel PI-line segments in reduced scans. Computer simulations and practical experiments are carried out to evaluate this algorithm. The BPF algorithm has a higher computational efficiency than the famous FDK algorithm. The BPF algorithm is evaluated using the practical CT projection data on a 450 keV X-ray CT system with a flat-panel detector (FPD). From the practical experiments, we get the spatial resolution of this CT system. The algo- rithm could achieve the spatial resolution of 2.4 lp/mm and satisfies the practical applications in industrial CT inspec- tion.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 50 条
  • [1] A Filtered Backprojection Algorithm for Triple-Source Helical Cone-Beam CT
    Zhao, Jun
    Jin, Yannan
    Lu, Yang
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) : 384 - 393
  • [2] Fan-beam filtered-backprojection reconstruction without backprojection weight
    Dennerlein, Frank
    Noo, Frederic
    Hornegger, Joachim
    Lauritsch, Guenter
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 3227 - 3240
  • [3] New approximate filtered backprojection algorithm for helical cone-beam CT with redundant data
    Kudo, H
    Noo, F
    Defrise, M
    Rodet, T
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3211 - 3215
  • [4] A filtered backprojection algorithm for axial head motion correction in fan-beam SPECT
    Li, JY
    Jaszczak, RJ
    Coleman, RE
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2053 - 2063
  • [7] Regularized iterative weighted filtered backprojection for helical cone-beam CT
    Sunnegardh, Johan
    Danielsson, Per-Erik
    MEDICAL PHYSICS, 2008, 35 (09) : 4173 - 4185
  • [8] Composite cone-beam filtered backprojection algorithm based on nutating line
    Wang Yu
    Ou Zong-ying
    Su Tie-ming
    Wang Feng
    OPTOELECTRONICS LETTERS, 2006, 2 (03) : 221 - 224
  • [9] Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data
    Zhuang, TL
    Leng, S
    Nett, BE
    Chen, GH
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24): : 5489 - 5503
  • [10] Composite cone-beam filtered backprojection algorithm based on nutating line
    Yu Wang
    Zong-ying Ou
    Tie-ming Su
    Feng Wang
    Optoelectronics Letters, 2006, 2 (3) : 221 - 224