Fabrication of a single-crystal diamond neutron detector and its application in 14.1 MeV neutron detection in deuterium–tritium fusion experiments

被引:0
|
作者
许平 [1 ]
余羿 [2 ]
周海洋 [3 ]
机构
[1] School of Physics, Xihua University
[2] Sino-French Institute of Nuclear Engineering and Technology, Sun Yat-sen University
[3] Department of Plasma Physics and Fusion Engineering, University of Science and Technology of China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TL816.3 []; TQ163 [人造超硬度材料的生产];
学科分类号
0817 ; 082704 ;
摘要
A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm × 4.5 mm × 500 μm.This film is sandwiched by a flat,strip-patterned gold electrode.The dark current of this detector is experimentally measured to be lower than 0.1 nA under an electric field of 30 kV cm-1.This diamond detector is used to measure D-T fusion neutrons with a flux of about 7.5 × 105 s-1cm-2.The pronounced peak with a central energy of 8.28 MeV characterizing the12C(n,α)9Be reaction in the neutron energy spectrum is experimentally diagnosed,and the energy resolution is better than 1.69%,which is the best result reported so far using a diamond detector.A clear peak with a central energy of 6.52 MeV characterizing the12C(n,n’) 3α reaction is also identified with an energy resolution of better than 7.67%.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [31] Simultaneous measurements for fast neutron flux and tritium production rate using pulse shape discrimination and single crystal CVD diamond detector
    Kobayashi, M. I.
    Yoshihashi, S.
    Ogawa, K.
    Isobe, M.
    Aso, T.
    Hara, M.
    Sangaroon, S.
    Tamaki, S.
    Murata, I.
    Toyama, S.
    Miwa, M.
    Matsuyama, S.
    Osakabe, M.
    NUCLEAR FUSION, 2024, 64 (06)
  • [32] Measurement of Neutron Reaction Cross Sections in Carbon using a Single Crystal Diamond Detector
    Pillon, M.
    Angelone, M.
    Krasa, A.
    Plompen, A. J. M.
    Schillebeeckx, P.
    Sergi, M. L.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [33] A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector
    Reginatto, Marcel
    Gagnon-Moisan, Francis
    Araque, Jorge Guerrero
    Nolte, Ralf
    Zboril, Miroslav
    Zimbal, Andreas
    BAYESIAN INFERENCE AND MAXIMUM ENTROPY METHODS IN SCIENCE AND ENGINEERING (MAXENT 2014), 2015, 1641 : 321 - 328
  • [34] Experimental response functions of a single-crystal diamond detector for 5-20.5 MeV neutrons
    Pillon, M.
    Angelone, M.
    Krasa, A.
    Plompen, A. J. M.
    Schillebeeckx, P.
    Sergi, M. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 640 (01): : 185 - 191
  • [35] Thermal neutron measurement by single crystal CVD diamond detector applied with the pulse shape discrimination during deuterium plasma experiment in LHD
    Kobayashi, Makoto I.
    Angelone, Maurizio
    Yoshihashi, Sachiko
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Nishitani, Takeo
    Sangaroon, Siriyaporn
    Kamio, Shuji
    Fujiwara, Yutaka
    Tsubouchi, Tomomi
    Uritani, Akira
    Sakama, Minoru
    Osakabe, Masaki
    FUSION ENGINEERING AND DESIGN, 2020, 161
  • [36] Combined X-ray and neutron single-crystal diffraction in diamond anvil cells
    Grzechnik, Andrzej
    Meven, Martin
    Paulmann, Carsten
    Friese, Karen
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2020, 53 : 9 - 14
  • [37] DESIGN AND TECHNIQUES FOR FUSION BLANKET NEUTRONICS EXPERIMENTS USING AN ACCELERATOR-BASED DEUTERIUM-TRITIUM NEUTRON SOURCE
    OYAMA, Y
    KONNO, C
    IKEDA, Y
    MAEKAWA, F
    MAEKAWA, H
    YAMAGUCHI, S
    TSUDA, K
    NAKAMURA, T
    ABDOU, MA
    BENNETT, EF
    MATTAS, RF
    PORGES, KG
    YOUSSEF, MZ
    FUSION TECHNOLOGY, 1995, 28 (01): : 56 - 73
  • [38] Neutron spectroscopy measurements of 14 MeV neutrons at unprecedented energy resolution and implications for deuterium-tritium fusion plasma diagnostics
    Rigamonti, D.
    Giacomelli, L.
    Gorini, G.
    Nocente, M.
    Rebai, M.
    Tardocchi, M.
    Angelone, M.
    Batistoni, P.
    Cufar, A.
    Ghani, Z.
    Jednorog, S.
    Klix, A.
    Laszynska, E.
    Loreti, S.
    Pillon, M.
    Popovichev, S.
    Roberts, N.
    Thomas, D.
    Litaudon, X.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V
    Sunden, E. Andersson
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (04)
  • [39] Development and high temperature testing by 14 MeV neutron irradiation of single crystal diamond detectors
    Pilotti, R.
    Angelone, M.
    Pagano, G.
    Loreti, S.
    Pillon, M.
    Sarto, F.
    Marinelli, M.
    Milani, E.
    Prestopino, G.
    Verona, C.
    Verona-Rinati, G.
    JOURNAL OF INSTRUMENTATION, 2016, 11 : 1 - 9
  • [40] STANDARDIZATION OF DT NEUTRON FIELD AND ITS APPLICATION TO DETECTOR CALIBRATION FOR FUSION DIAGNOSTICS
    KUDO, K
    KINOSHITA, T
    FUSION ENGINEERING AND DESIGN, 1989, 10 : 145 - 149