The Transient Modal Dynamic Analysis of a Coke Tower

被引:0
|
作者
XIE Teng-teng
机构
关键词
wind load; coke tower; dynamic analysis; vibration; resonance;
D O I
10.13434/j.cnki.1007-4546.2012.03.001
中图分类号
TQ520.5 [机械与设备];
学科分类号
摘要
Dynamic analysis must be performed when the duration of the applied load is short or if the load is dynamic in nature. Wind load, as a random load, can lead to the vibration of the coke tower. In order to study the influence to the strength of the coke tower by wind, ABAQUS was used to conduct the transient modal dynamic analysis of the wind load. The response of the structure during loading and unloading was mainly observed. The results indicate that, with the effect of wind, the maximal nodal displacement appears at the top of the tower, which is 0.79 mm; while the maximal stress locates at the node around the skirt, the maximum is 3.26 MPa. Both of the displacement and stress cannot cause the failure of the structure. After loading and unloading, the structure engenders vibration along the loading direction. The frequency is 10 Hz, under the effect of external loads, it may easily cause the resonance of the structure, which can cause damage to the structure. So it must be taken into consideration during the process of design and operation.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [31] Modal analysis of a wind turbine tower by digital image correlation
    Curt, Jordan
    Capaldo, Matteo
    Hild, Francois
    Roux, Stephane
    SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2020), PTS 1-5, 2020, 1618
  • [32] Dynamic Analysis of a Large Freestanding Rock Tower (Castleton Tower, Utah)
    Moore, Jeffrey R.
    Geimer, Paul R.
    Finnegan, Riley
    Michel, Clotaire
    BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 2019, 109 (05) : 2125 - 2131
  • [33] Lightning Transient Analysis of Telecommunication System With a Tubular Tower
    Chen, Hongcai
    Zhang, Yang
    Du, Yaping
    Cheng, Qingsha S.
    IEEE ACCESS, 2018, 6 : 60088 - 60099
  • [34] Modal analysis for the transient internal voltage of a transformer
    Song, S
    Kim, HS
    Chung, TK
    Hahn, SY
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (02) : 581 - 584
  • [35] A transient modal analysis of a BWR instability event
    Ginestar, D
    Miró, R
    Verdú, G
    Hennig, D
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (05) : 554 - 563
  • [36] Modal and transient analysis of membrane acoustic metasurfaces
    Lani, Shane
    Sabra, Karim G.
    Degertekin, F. Levent
    JOURNAL OF APPLIED PHYSICS, 2015, 117 (04)
  • [37] MODAL APPROACH TO TRANSIENT ANALYSIS OF SYNCHRONOUS MACHINES
    KALSI, SS
    LIPO, TA
    ELECTRIC MACHINES AND ELECTROMECHANICS, 1977, 1 (04): : 337 - 354
  • [38] Dynamic investigation of an ancient masonry bell tower with operational modal analysis a non-destructive experimental technique to obtain the dynamic characteristics of a structure
    Foti, Dora
    Ivorra Chorro, Salvador
    Sabbà, Maria Francesca
    Foti, D. (d.foti@poliba.it), 1600, Bentham Science Publishers B.V., P.O. Box 294, Bussum, 1400 AG, Netherlands (06): : 384 - 391
  • [39] MODELING OF A FIXED OFFSHORE TOWER IN DYNAMIC ANALYSIS
    MUKHOPADHYAY, M
    SINHA, SK
    OCEAN ENGINEERING, 1988, 15 (06) : 611 - 632
  • [40] NONLINEAR DYNAMIC ANALYSIS OF COOLING TOWER.
    Yeh, Chang-hua