Ground experimental investigations into an ejected spray cooling system for space closed-loop application

被引:0
|
作者
Zhang Hongsheng [1 ]
Li Yunze [1 ]
Wang Shengnan [2 ]
Liu Yang [1 ]
Zhong Mingliang [1 ]
机构
[1] School of Aeronautic Science and Engineering,Beihang University
[2] School of Automation Science and Electrical Engineering,Beihang University
基金
中国国家自然科学基金;
关键词
Ejected spray cooling system; Evaluation models; Ground experiment; Heat transfer performance; High heat flux; Space closed-loop;
D O I
暂无
中图分类号
TK124 [传热学];
学科分类号
080701 ;
摘要
Spray cooling has proved its superior heat transfer performance in removing high heat flux for ground applications.However,the dissipation of vapor–liquid mixture from the heat surface and the closed-loop circulation of the coolant are two challenges in reduced or zero gravity space environments.In this paper,an ejected spray cooling system for space closed-loop application was proposed and the negative pressure in the ejected condenser chamber was applied to sucking the two-phase mixture from the spray chamber.Its ground experimental setup was built and experimental investigations on the smooth circle heat surface with a diameter of 5 mm were conducted with distilled water as the coolant spraying from a nozzle of 0.51 mm orifice diameter at the inlet temperatures of 69.2 °C and 78.2 °C under the conditions of heat flux ranging from 69.76 W/cm2to 311.45 W/cm2,volume flow through the spray nozzle varying from 11.22 L/h to 15.76 L/h.Work performance of the spray nozzle and heat transfer performance of the spray cooling system were analyzed;results show that this ejected spray cooling system has a good heat transfer performance and provides valid foundation for space closed-loop application in the near future.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 50 条
  • [21] Closed-loop cooling technologies for microprocessors
    Upadhya, G
    Zhou, P
    Goodson, K
    Munch, M
    Kenny, T
    2003 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, TECHNICAL DIGEST, 2003, : 775 - 778
  • [22] Closed-loop electroosmotic microchannel cooling system for VLSI circuits
    Jiang, LN
    Mikkelsen, J
    Koo, JM
    Huber, D
    Yao, SH
    Zhang, L
    Zhou, P
    Maveety, JG
    Prasher, R
    Santiago, JG
    Kenny, TW
    Goodson, KE
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2002, 25 (03): : 347 - 355
  • [23] Safe and Ecological Refluxing with a Closed-Loop Air Cooling System
    Böhmdorfer S.
    Eilenberger G.
    Zweckmair T.
    Sumerskii I.
    Potthast A.
    Rosenau T.
    Böhmdorfer, Stefan (stefan.boehmdorfer@boku.ac.at), 1600, Wiley-VCH Verlag (10): : 461 - 465
  • [24] CLOSED-LOOP COOLING UNIT ELIMINATES ELECTRONIC SYSTEM FAILURES
    STEFANIDES, EJ
    DESIGN NEWS, 1985, 41 (14) : 96 - 98
  • [25] Safe and Ecological Refluxing with a Closed-Loop Air Cooling System
    Boehmdorfer, Stefan
    Eilenberger, Gottfried
    Zweckmair, Thomas
    Sumerskii, Ivan
    Potthast, Antje
    Rosenau, Thomas
    CHEMSUSCHEM, 2017, 10 (02) : 461 - 465
  • [26] Experimental and computational analysis of a passive containment cooling system with closed-loop heat pipe technology
    Lu Changdong
    Ji Wenying
    Yang Jiang
    Cai Wei
    Wang Ting
    Cheng Cheng
    Xiao Hong
    PROGRESS IN NUCLEAR ENERGY, 2019, 113 : 206 - 214
  • [27] Experimental and Computational Analysis of a Passive Containment Cooling System with Closed-loop Heat Pipe Technology
    Lu Changdong
    Ji Wenying
    Yang Jiang
    Cai Wei
    Wang Ting
    Cheng Chehg
    Xiao Hon
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2020, 65 (05): : 280 - 286
  • [29] Heat transfer characteristics in closed-loop spray cooling of micro-structured surfaces
    Zhang, Wei
    Wang, Zhaoliang
    Xu, Minghai
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2012, 24 (09): : 2053 - 2058
  • [30] BACTERIAL FOULING OF A HOSPITAL CLOSED-LOOP COOLING SYSTEM BY PSEUDOMONAS SP
    DUMOULIN, GC
    DOYLE, GO
    MACKAY, J
    HEDLEYWHYTE, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 13 (06) : 1060 - 1065