Three-Tesla magnetic resonance elastography for hepatic fibrosis:Comparison with diffusion-weighted imaging and gadoxetic acid-enhanced magnetic resonance imaging

被引:7
|
作者
Hee Sun Park [1 ]
Young Jun Kim [1 ]
Mi Hye Yu [1 ]
Won Hyeok Choe [2 ]
Sung Il Jung [1 ]
Hae Jeong Jeon [1 ]
机构
[1] Department of Radiology,Konkuk University School of Medicine,Seoul 143-729,South Korea
[2] Digestive Disease Center,Konkuk University School of Medicine,Seoul 143-729,South Korea
关键词
Magnetic resonance elastography; Hepatic fibrosis; Diffusion weighted imaging; Gadoxetic acid enhanced magnetic resonance imaging; Serum markers;
D O I
暂无
中图分类号
R575.2 [肝硬变]; R445.2 [核磁共振成像];
学科分类号
1002 ; 100201 ; 100207 ;
摘要
AIM:To evaluate the feasibility of 3-Tesla magnetic resonance elastography(MRE)for hepatic fibrosis and to compare that with diffusion-weighted imaging(DWI)and gadoxetic acid-enhanced magnetic resonance(MR)imaging.METHODS:Forty-two patients were included in the study.On MRE,mean stiffness values were measured on the elastograms in kilopascals.The apparent diffusion coefficient(ADC)of the liver was measured using DWI.On gadoxetic acid enhanced MR,the contrast enhancement index(CEI)was calculated as signal intensity(SI)post/SIpre,where SIpost is liver-to-muscle SI ratio on hepatobiliary phase images and SIpre is that on nonenhanced images.Correlation between aspartate aminotransferase to the platelet ratio index(APRI)and three MR parameters was assessed.Each MR parameter was compared between a hepatic fibrosis(HF)group and non-hepatic fibrosis(n HF)group.RESULTS:Liver stiffness showed strong positive correlation with APRI[Spearman correlation coeffiecient(r)=0.773,P<0.0001],while ADC and CEI showed weak or prominent negative correlation(r=-0.28 and-0.321,respectively).In the HF group,only liver stiffness showed strong correlation with APRI(r=0.731,P<0.0001).Liver stiffness,ADC,and APRI were significantly different between the HF group and n HF group.CONCLUSION:MRE at 3-Tesla could be a feasible method for the assessment of hepatic fibrosis.
引用
收藏
页码:17558 / 17567
页数:10
相关论文
共 50 条
  • [21] MRI-based staging of hepatic fibrosis: Comparison of intravoxel incoherent motion diffusion-weighted imaging with magnetic resonance elastography
    Ichikawa, Shintaro
    Motosugi, Utaroh
    Morisaka, Hiroyuki
    Sano, Katsuhiro
    Ichikawa, Tomoaki
    Enomoto, Nobuyuki
    Matsuda, Masanori
    Fujii, Hideki
    Onishi, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (01) : 204 - 210
  • [22] Comparison of Magnetic Resonance Elastography and Gadoxetate Disodium-Enhanced Magnetic Resonance Imaging for the Evaluation of Hepatic Fibrosis
    Choi, Ye Ra
    Lee, Jeong Min
    Yoon, Jeong Hee
    Han, Joon Koo
    Choi, Byung Ihn
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 607 - 613
  • [23] Diffusion-weighted Magnetic Resonance Imaging for the Staging of Liver Fibrosis
    Bonekamp, Susanne
    Torbenson, Michael S.
    Kamel, Ihab R.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2011, 45 (10) : 885 - 892
  • [24] Comparison of the effect of region-of-interest methods using gadoxetic acid-enhanced MR imaging with diffusion-weighted imaging on staging hepatic fibrosis
    Ying Ding
    Shengxiang Rao
    Li Yang
    Caizhong Chen
    Mengsu Zeng
    La radiologia medica, 2016, 121 : 821 - 827
  • [25] Breast Magnetic Resonance Imaging: Diffusion-Weighted Imaging
    Brandao, Alice C.
    Lehman, Constance D.
    Partridge, Savannah C.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (02) : 321 - +
  • [26] Impact of baseline gadoxetic acid-enhanced liver magnetic resonance and diffusion-weighted imaging in resectable colorectal liver metastases: A prospective, monocentric study
    Moretto, Roberto
    Borelli, Beatrice
    Boraschi, Piero
    Roffi, Nicolo
    Donati, Francescamaria
    Antoniotti, Carlotta
    Della Pina, Clotilde
    Colombatto, Piero
    Balestri, Riccardo
    Signori, Stefano
    Gigoni, Roberto
    Guidoccio, Federica
    Volterrani, Duccio
    Masi, Gianluca
    Cremolini, Chiara
    Urbani, Lucio
    SURGICAL ONCOLOGY-OXFORD, 2022, 44
  • [27] Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis
    Koinuma, M
    Ohashi, I
    Hanafusa, K
    Shibuya, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 80 - 85
  • [28] Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B
    Hennedige, Tiffany P.
    Wang, Gang
    Leung, Fiona P.
    Alsaif, Hind S.
    Teo, Lynette L. S.
    Lim, Seng Gee
    Wee, Aileen
    Venkatesh, Sudhakar K.
    GUT AND LIVER, 2017, 11 (03) : 401 - 408
  • [29] Gadoxetic acid-enhanced magnetic resonance imaging in the assessment of hepatic sinusoidal obstruction syndrome in a mouse model
    Chen, Yuan-Yuan
    Yang, Li
    Li, Jun
    Rao, Sheng-Xiang
    Ding, Ying
    Zeng, Meng-Su
    WORLD JOURNAL OF HEPATOLOGY, 2024, 16 (08)
  • [30] Detection of Liver Fibrosis: Comparison of Magnetic Resonance Elastography and Diffusion-Weighted MRI
    Venkatesh, S.
    Teo, L.
    Ang, B.
    Ehman, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)