Waste heat water pumping model with direct contact cooling

被引:0
|
作者
Kittiwoot Sutthivirode [1 ]
Naris Pratinthong [1 ]
Pichai Namprakai [1 ]
Natthaphon Roonprasang [2 ]
Taveewat Suparos [3 ]
机构
[1] Division of Energy Technology, School of Energy, Environment and Materials,King Mongkut's University of Technology Thonburi
[2] Department of Alternative Energy Development and Efficiency Ministry of Energy,Bureau of Energy Regulation and Conservation  3. Department of Mechanical Technology Education, Faculty of Industrial Edu
关键词
direct contact cooling; driving tank; steam-air power; liquid piston; waste heat;
D O I
暂无
中图分类号
X706 [废热利用]; TH38 [各种用途];
学科分类号
摘要
The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for underground water. In this model, a heater installed within the heat tank represented sources of waste heat as energy input for finding appropriate conditions of the 10 L pump model. The system operation had five stages: heating, pumping, vapor flow, cooling, and water suction. The overall water heads of 3, 4.5, 6 and 7.5 m were tested. At the same time, it was found that the pump with 50% air volume is sufficient for pumping water to a desired level. In the experiment, the temperatures in the heating and pumping stages were 100-103 °C and 80-90 °C, respectively. The pressure in the pumping stage was 12-18 kPa, and the pressure in the suction stage was about-80 kPa, sufficient for the best performance. It could pump 170 L of water at a 2 m suction head, 120 L at a 3.5 m suction head, 100 L at a 5 m suction head, and 65 L at a 6.5 m suction head in 2 h. A mathematical model for larger pumps was also presented, which operates nearly the same as the present system. Economic analysis of the 10 L pump was also included.
引用
收藏
页码:3896 / 3910
页数:15
相关论文
共 50 条
  • [41] Experimental evaluation on concentrating cooling tower blowdown water by direct contact membrane distillation
    Yu, Xianguo
    Yang, Hai
    Lei, Hui
    Shapiro, Andrew
    DESALINATION, 2013, 323 : 134 - 141
  • [42] Ice Slurry Generation for Direct Contact Cooling
    Fumoto, Koji
    Sato, Toshiki
    Kawanami, Tsuyoshi
    Inamura, Takao
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2016, 8 (02)
  • [43] Melt crystallization with direct contact cooling techniques
    Kim, KJ
    Mersmann, A
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1997, 75 (A2): : 176 - 182
  • [44] Melt crystallization with direct contact cooling techniques
    Kim, Kwang-Joo
    Mersmann, A.
    Chemical Engineering Research and Design, 1997, 75 (A2): : 176 - 182
  • [45] Thermodynamics of Cascaded Waste Heat Utilization from Flue Gas and Circulating Cooling Water
    Li, Yuanyuan
    Chen, Xin
    Jiang, Shan
    Lu, Gui
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (06) : 2166 - 2178
  • [46] Thermodynamics of Cascaded Waste Heat Utilization from Flue Gas and Circulating Cooling Water
    Yuanyuan Li
    Xin Chen
    Shan Jiang
    Gui Lu
    Journal of Thermal Science, 2023, 32 : 2166 - 2178
  • [47] Thermodynamics of Cascaded Waste Heat Utilization from Flue Gas and Circulating Cooling Water
    LI Yuanyuan
    CHEN Xin
    JIANG Shan
    LU Gui
    JournalofThermalScience, 2023, 32 (06) : 2166 - 2178
  • [48] Reducing pumping costs for industrial cooling and service water
    Andrews, G
    ENERGY SAVING IN THE DESIGN AND OPERATION OF PUMPS, 1996, : 123 - 141
  • [49] Optimal design and operation of cooling water pumping systems
    Pontes R.F.F.
    Pinto J.M.
    Silva E.K.G.
    Computers and Chemical Engineering, 2022, 157
  • [50] MANUFACTURER'S VIEWPOINT ON DIRECT CONTACT AIR TO WATER HEAT EXCHANGERS.
    Andrews, P.J.
    Journal of the Mine Ventilation Society of South Africa, 1985, 38 (07) : 73 - 78