Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode

被引:0
|
作者
WANG Juan~1
2. Department of Environmental Engineer
机构
关键词
epinephrine; carbon nanotube; glassy carbon electrode; modified electrode;
D O I
暂无
中图分类号
O657.1 [电化学分析法];
学科分类号
摘要
The electrochemical behavior of epinephrine at activated glassy carbon electrode and carbon nanotube-coated glassy carbon electrode was studied. Epinephrine could exhibit an anodic peak at about 0.2 V (vs. SCE) at bare glassy carbon electrode, but it was very small. However, when the electrode was activated at certain potential (i.e. 1.9 V) or modified with carbon nanotube, the peak became more sensitive, resulting from the increase in electrode area in addition to the electrostatic attraction. Under the selected conditions, the anodic peak current was linear to epinephrine concentration in the range of 3.3×10~-7-1.1×10~-5 mol/L at activated glassy carbon electrode and in the range of 1.0×10~-6-5.0×10~-5 mol/L at carbon nanotube-coated electrode. The correlation coefficients were 0.998 and 0.997, respectively. The determination limit was 1.0×10~-7 mol/L. The two electrodes have been successfully applied for the determination of epinephrine in adrenaline hydrochloride injection with recovery of 95%-104%.
引用
收藏
页码:913 / 918
页数:6
相关论文
共 50 条
  • [31] Voltammetric studies on the interaction of epinephrine with DNA base on a glassy carbon electrode modified with Au nanoparticles
    Wang, Xueliang
    Li, Jinjin
    Wang, Tao
    Yu, Zhangyu
    IONICS, 2015, 21 (04) : 1105 - 1110
  • [32] Voltammetric study of saffron in blood mediated by modified glassy carbon electrode (GCE) with carbon nanotube (CNT/GCE)
    Radhi, Muhammed Mizher
    Khalaf, Maysara Samer
    Ali, Zainab Oun
    Al-Dabbagh, Thamir Aboud
    EPITOANYAG-JOURNAL OF SILICATE BASED AND COMPOSITE MATERIALS, 2018, 70 (03): : 78 - 81
  • [33] Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube
    Noroozifar, M.
    Khorasani-Motlagh, M.
    Akbari, R.
    Parizi, M. Bemanadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2014, 1 (01): : 62 - 72
  • [34] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617
  • [35] Electrochemical behavior and voltammetric determination of epinephrine by different pretreated glassy carbon electrode
    Li, Zhiguo
    Hu, Yanfei
    Liu, Yuge
    Jia, Yongmei
    Ye, Cui
    Zhang, Lingling
    Chinese Journal of Analysis Laboratory, 2022, 41 (08) : 920 - 924
  • [36] Electrocatalytic oxidation of hydrazine at epinephrine modified glassy carbon electrode (EPMGCE).
    Golabi, SM
    Mirzazadeh, J
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2003, 22 (01): : 43 - 54
  • [37] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [38] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [39] Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid
    Soman, Sithara
    Ramakrishnan, Kala
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (12) : 2831 - 2843
  • [40] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519