Treatment of tibial defect and bone nonunion with limb shortening with external fixator and reconstituted bone xenograft

被引:0
|
作者
王志刚
刘建
胡蕴玉
孟国林
金格勒
袁志
王海强
戴先文
机构
[1] Orthopaedic Department of Xijing Hospital
[2] China
[3] Orthopaedic Department of Xijing Hospital Fourth Military Medical University
[4] Xi’an 710032
关键词
External fixators; Bone transplantation; Bone lengthening; Bone defects;
D O I
暂无
中图分类号
R687.3 [骨骼手术];
学科分类号
1002 ; 100210 ;
摘要
Objective: To explore the effect of external fixator and reconstituted bone xenograft (RBX) in the treatment of tibial bone defect, tibial bone nonunion and congenital pseudarthrosis of the tibia with limb shortening. Methods: Twenty patients ( 13 males and 7 females) with tibial bone defect, tibial bone nonunion or congenital pseudarthrosis of the tibia with limb shortening were treated with external fixation. Two kinds of external fixators were used: a half ring sulcated external fixator used in 13 patients and a combined external fixator in 7 patients. Foot-drop was corrected at the same time with external fixation in 4 patients. The shortened length of the tibia was in the range of 2-9 cm, with an average of 4.8 cm. For bone grafting, RBX was used in 12 patients, autogenous ilium was used in 3 patients and autogenous fibula was implanted as a bone plug into the medullary canal in 1 case, and no bone graft was used in 4 patients. Results: All the 20 patients were followed-up for 8 months to 7 years, averaging 51 months. Satisfactory function of the affected extremities was obtained. All the shortened extremities were lengthened to the expected length. For all the lengthening area and the fracture sites, bone union was obtained at the last. The average healing time of 12 patients treated with RBX was 4.8 months. Conclusions: Both the half ring sulcated external fixator and the combined external fixator have the advantages of small trauma, simple operation, elastic fixation without stress shielding and non-limitation from local soft tissue conditions, and there is satisfactory functional recovery of affected extremities in the treatment of tibial bone defects, tibial bone nonunion and congenital pseudarthrosis of the tibia combined with limb shortening. RBX has good biocompatibility and does not cause immunological rejections. It can also be safely used in treatment of bone nonunion and has reliable effect to promote bone healing.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 50 条
  • [31] The treatment of infected tibial nonunion with aggressive debridement and internal bone transport
    Atesalp, AS
    Komurcu, M
    Basbozkurt, M
    Kurklu, M
    MILITARY MEDICINE, 2002, 167 (12) : 978 - 981
  • [32] The treatment of osteomyelitis with gentamicin-reconstituted bone xenograft-composite
    Li, XD
    Hu, YY
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (07): : 1063 - 1068
  • [33] HUGHES EXTERNAL FIXATOR IN TREATMENT OF TIBIAL FRACTURES
    COURTBROWN, CM
    HUGHES, SPF
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1985, 78 (10) : 830 - 837
  • [34] Treatment of a Large Tibial Non-Union Bone Defect in a Cat Using Xenograft with Canine-Derived Cancellous Bone, Demineralized Bone Matrix, and Autograft
    Kim, Keun-Yung
    Oh, Minha
    Kim, Minkyung
    ANIMALS, 2024, 14 (05):
  • [35] Efficacy comparison of trifocal bone transport using unilateral external fixator for femoral and tibial bone defects caused by infection
    Liu, Kai
    Liu, Yanshi
    Cai, Feiyu
    Fan, Chenchen
    Ren, Peng
    Yusufu, Aihemaitijiang
    BMC SURGERY, 2022, 22 (01)
  • [36] Efficacy comparison of trifocal bone transport using unilateral external fixator for femoral and tibial bone defects caused by infection
    Kai Liu
    Yanshi Liu
    Feiyu Cai
    Chenchen Fan
    Peng Ren
    Aihemaitijiang Yusufu
    BMC Surgery, 22
  • [37] Anti-infective reconstituted bone xenograft used for primary bone grafting to repair contaminated defect in the radius in dogs
    袁志
    赵黎
    胡蕴玉
    刘建
    孙梁
    李丹
    廉凯
    吕荣
    中华创伤杂志(英文版), 2003, (02) : 23 - 27
  • [38] Anti-infective reconstituted bone xenograft used for primary bone grafting to repair contaminated defect in the radius in dogs
    袁志
    赵黎
    胡蕴玉
    刘建
    孙梁
    李丹
    廉凯
    吕荣
    Chinese Journal of Traumatology, 2003, (02)
  • [39] A cost analysis of treatment of tibial fracture nonunion by bone grafting or bone morphogenetic protein-7
    Z. Dahabreh
    G. M. Calori
    N. K. Kanakaris
    V. S. Nikolaou
    P. V. Giannoudis
    International Orthopaedics, 2009, 33
  • [40] Acrylic external fixator with percutancous bone screws for the treatment of long bone fractures in miniature dogs
    Franch, J.
    Fontecha, P.
    Font, C.
    Sanna, M.
    Diaz-Bertrana, M. C.
    Durall, I.
    CLINICA VETERINARIA DE PEQUENOS ANIMALES, 2007, 27 (02): : 127 - 136