A capture-gated fast neutron detection method

被引:0
|
作者
刘毅 [1 ,2 ]
杨祎罡 [1 ,2 ]
邰杨 [1 ,2 ]
张智 [1 ,2 ]
机构
[1] Department of Engineering Physics, Tsinghua University
[2] Key Laboratory of Particle & Radiation Imagaing, Tisinghua University, Ministry of Education
基金
中国国家自然科学基金;
关键词
neutron detector; homeland security; nuclear physics;
D O I
暂无
中图分类号
O571.5 [中子物理];
学科分类号
0827 ; 082701 ;
摘要
To address the problem of the shortage of neutron detectors used in radiation portal monitors(RPMs),caused by the;He supply crisis, research on a cadmium-based capture-gated fast neutron detector is presented in this paper. The detector is composed of many 1 cm × 1 cm × 20 cm plastic scintillator cuboids covered by 0.1 mm thick film of cadmium. The detector uses cadmium to absorb thermal neutrons and produce capture γ-rays to indicate the detection of neutrons, and uses plastic scintillator to moderate neutrons and register γ-rays. This design removes the volume competing relationship in traditional;He counter-based fast neutron detectors, which hinders enhancement of the neutron detection efficiency. Detection efficiency of 21.66% ± 1.22% has been achieved with a 40.4 cm × 40.4cm × 20 cm overall detector volume. This detector can measure both neutrons and γ-rays simultaneously. A small detector(20.2 cm × 20.2 cm × 20 cm) demonstrated a 3.3 % false alarm rate for a;Cf source with a neutron yield of 1841 n/s from 50 cm away within 15 s measurement time. It also demonstrated a very low(<0.06%) false alarm rate for a 3.21 × 10;Bq;Cs source. This detector offers a potential single-detector replacement for both neutron and the γ-ray detectors in RPM systems.
引用
收藏
页码:120 / 127
页数:8
相关论文
共 50 条
  • [41] High grade gliomas irradiation: use of fast neutrons, boron neutron capture therapy (BNCT) and boron neutron capture enhancement of fast neutron (BNCEFN)
    Paquis, P
    Pignol, JP
    Breteau, N
    NEUROCHIRURGIE, 2000, 46 (01) : 23 - 33
  • [42] Treatment planning for boron neutron capture enhanced fast neutron therapy
    Kota, C
    Burmeister, J
    Maughan, R
    Levin, K
    Chuba, P
    Gaspar, L
    Forman, J
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 723 - 728
  • [43] An MRPC for fast neutron detection
    王义
    程建平
    李元景
    罗明
    张国光
    中国物理C, 2010, 34 (01) : 88 - 91
  • [44] An MRPC for fast neutron detection
    Wang Yi
    Cheng Jian-Ping
    Li Yuan-Jing
    Luo Ming
    Zhang Guo-Guang
    CHINESE PHYSICS C, 2010, 34 (01) : 88 - 91
  • [45] Boron neutron capture enhancement of fast neutron-induced cell kill as a function of fast neutron fraction size
    Stelzer, KJ
    Laramore, GE
    Risler, R
    Wilbur, DS
    Wiens, L
    Griffin, TW
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : B463 - B467
  • [46] γ-Flash suppression using a gated photomultiplier assembled with an LaBr3(Ce) detector to measure fast neutron capture reactions
    Hara, K. Y.
    Harada, H.
    Toh, Y.
    Hori, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 723 : 121 - 127
  • [47] FAST NEUTRON CAPTURE CROSS SECTIONS AND SHELL STRUCTURE
    HUGHES, DJ
    GARTH, RC
    PHYSICAL REVIEW, 1951, 83 (01): : 234 - 234
  • [48] PROPOSALS FOR INVESTIGATION OF FAST NEUTRON CAPTURE BY LIGHTEST NUCLEI
    ILAKOVAC, K
    KNAPP, V
    NUCLEAR PHYSICS, 1963, 43 (01): : 69 - &
  • [49] MEASUREMENTS OF FAST-NEUTRON CAPTURE INTEGRALS IN CFRMF
    SCOVILLE, JJ
    NISLE, RG
    HOWES, BW
    HARKER, YD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (02): : 755 - &
  • [50] FAST NEUTRON RADIATIVE CAPTURE CROSS SECTION FOR IRON
    MALISHEV, AV
    STAVISSK.YY
    SHAPAR, AV
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1965, 19 (11PA): : 918 - &