Sensitive determination of buformin using poly-aminobenzoic acid modified glassy carbon electrode

被引:1
|
作者
Gui-Ying Jin [1 ]
Hui Li [1 ]
Wan-Bang Xu [1 ]
机构
[1] Guangdong Institute for Drug Control
关键词
Chemically modified electrode; Aminobenzoic acid; Buformin;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Glassy carbon electrode, which is used to electrochemically determine the content of buformin, is modified with an electropolymerized film of p-aminobenzoic acid in pH 7.0 acetate buffer solution (ABS). The polymer showed an excellent electrocatalytic activity for the reduction of buformin. In pH 7.0 ABS, the cathodic peak current increased linearly over three concentration intervals of buformin, and the detection limit (S/N=3) was 2.0×10-9 g/mL. The method was successfully applied to directly determine buformin in tablets with standard addition recoveries of 95.8-102.5%. The proposed method is simple, cheap and highly efficient.
引用
收藏
页码:458 / 461
页数:4
相关论文
共 50 条
  • [41] Determination of Amino Group Content on Nanosilicas with p-Aminobenzoic Acid Modified Glassy Carbon Electrode Using Copper(II) as Intermedia
    Chang, Zhixian
    Qu, Jianying
    Zhang, Ling
    Li, Deliang
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (06) : 2424 - 2426
  • [42] Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Aslisen, Burak
    Karabiberoglu, Sukriye
    Ozdokur, Kemal Volkan
    Aslan, Avni
    Kocak, Suleyman
    CHEMISTRYSELECT, 2022, 7 (41):
  • [43] Sensitive determination of dopamine on poly(aminobenzoic acid) modified electrode and the application toward an experimental Parkinsonian animal model
    Xu, F
    Gao, MN
    Wang, L
    Shi, GY
    Zhang, W
    Jin, LT
    Jin, JY
    TALANTA, 2001, 55 (02) : 329 - 336
  • [44] A glassy carbon electrode modified with poly(anthranilic acid), poly(diphenylamine sulfonate) and CuO nano-particles for the sensitive determination of hydrogen peroxide
    Haiyan Song
    Yongnian Ni
    Serge Kokot
    Microchimica Acta, 2013, 180 : 1263 - 1270
  • [45] A glassy carbon electrode modified with poly(anthranilic acid), poly(diphenylamine sulfonate) and CuO nano-particles for the sensitive determination of hydrogen peroxide
    Song, Haiyan
    Ni, Yongnian
    Kokot, Serge
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1263 - 1270
  • [46] Sensitive Determination of Copper on New Modified Glassy Carbon Paste Electrode
    Skrivanj, Sandra
    Stankovic, Dalibor M.
    Khan, Muslim
    Nikolic, Aleksandar S.
    Vulic, Predrag
    Manojlovic, Dragan D.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (02): : 230 - 241
  • [47] A selective determination of norepinephrine on the glassy carbon electrode modified with poly(ethylenedioxypyrrole dicarboxylic acid) nanofibers
    Heejin Seol
    Haesang Jeong
    Seungwon Jeon
    Journal of Solid State Electrochemistry, 2009, 13 : 1881 - 1887
  • [48] Electrochimical determination of uric acid, xanthine and hypoxanthine by poly(xylitol) modified glassy carbon electrode
    窦志宇
    崔丽莉
    何兴权
    Journal of Central South University, 2014, 21 (03) : 870 - 876
  • [49] A glassy carbon electrode modified with a polyaniline doped with silicotungstic acid and carbon nanotubes for the sensitive amperometric determination of ascorbic acid
    Xiaowen Zhang
    Guosong Lai
    Aimin Yu
    Haili Zhang
    Microchimica Acta, 2013, 180 : 437 - 443
  • [50] Determination of L-DOPA at an optimized poly(caffeic acid) modified glassy carbon electrode
    Rohanifar, Ahmad
    Devasurendra, Amila M.
    Young, Joshua A.
    Kirchhoff, Jon R.
    ANALYTICAL METHODS, 2016, 8 (44) : 7891 - 7897