Improved image resolution on thoracic carcinomas by quantitative 18F-FDG coincidence SPECT/CT in comparison to 18F-FDG PET/CT

被引:0
|
作者
Yuming Zheng [1 ]
Chaoling Jin [1 ]
Huijuan Cui [2 ]
Haojie Dai [3 ]
Jue Yan [1 ]
Pingping Han [1 ]
Bailing Hsu [4 ]
机构
[1] Nuclear Medicine Department,China-Japan Friendship Hospital
[2] Oncology of Integrative Medicine Department,China-Japan Friendship Hospital
[3] Nuclear Medicine Department,Danli Hospital  4. Nuclear Science and Engineering Institute,University of Missouri-Columbia
关键词
D O I
暂无
中图分类号
R730.44 [放射线、同位素诊断];
学科分类号
100105 ;
摘要
Currently,18F-FDG coincidence SPECT(Co-SPECT)/CT scan still serves as an important tool for diagnosis,staging,and evaluation of cancer treatment in developing countries.We implemented full physical corrections(FPC) to Co-SPECT(quantitative Co-SPECT) to improve the image resolution and contrast along with the capability for image quantitation.FPC included attenuation,scatter,resolution recovery,and noise reduction.A standard NEMA phantom filled with 10:1 F-18 activity concentration ratio in spheres and background was utilized to evaluate image performance.Subsequently,15 patients with histologically confirmed thoracic carcinomas were included to undergo a 18 F-FDG Co-SPECT/CT scan followed by a 18 F-FDG PET/CT scan.Functional parameters as SUVmax,SUVmean,SULpeak,and MTV from both quantitative Co-SPECT and PET were analyzed.Image resolution of Co-SPECT for NEMA phantom was improved to reveal the smallest sphere from a diameter of 28 mm to 22 mm(17 mm for PET).The image contrast was enhanced from 1.7 to 6.32(6.69 for PET) with slightly degraded uniformity in background(3.1% vs.6.7%)(5.6% for PET).Patients’ SUVmax,SUVmean,SULpeak,and MTV measured from quantitative Co-SPECT were overall highly correlated with those from PET(r=0.82-0.88).Adjustment of the threshold of SUVmax and SUV to determine SUVmean and MTV did not further change the correlations with PET(r=0.81-0.88).Adding full physical corrections to Co-SPECT images can significantly improve image resolution and contrast to reveal smaller tumor lesions along with the capability to quantify functional parameters like PET/CT.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 50 条
  • [21] Prospective comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for thoracic staging of non-small cell lung cancer
    Julian Kirchner
    Lino M. Sawicki
    Felix Nensa
    Benedikt M. Schaarschmidt
    Henning Reis
    Marc Ingenwerth
    Simon Bogner
    Clemens Aigner
    Christian Buchbender
    Lale Umutlu
    Gerald Antoch
    Ken Herrmann
    Philipp Heusch
    European Journal of Nuclear Medicine and Molecular Imaging, 2019, 46 : 437 - 445
  • [22] The comparative performances of 18F-FDG PET/MRI and 18F-FDG PET/CT for the detection of pancreatic neoplasms
    Xing, H.
    Hou, B.
    Zhu, W.
    Ding, H.
    Li, X.
    Hu, Y.
    Xue, H.
    Feng, F.
    Lv, K.
    Wu, X.
    Li, F.
    Jin, Z.
    Li, D.
    Huo, L.
    Zhao, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S501 - S501
  • [23] Prospective comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for thoracic staging of non-small cell lung cancer
    Kirchner, Julian
    Sawicki, Lino M.
    Nensa, Felix
    Schaarschmidt, Benedikt M.
    Reis, Henning
    Ingenwerth, Marc
    Bogner, Simon
    Aigner, Clemens
    Buchbender, Christian
    Umutlu, Lale
    Antoch, Gerald
    Herrmann, Ken
    Heusch, Philipp
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (02) : 437 - 445
  • [24] Prospective comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for thoracic staging of non-small cell lung cancer
    Kirchner, J.
    Sawicki, L. M.
    Schaarschmidt, B. M.
    Umutlu, L.
    Herrmann, K.
    Buchbender, C.
    Antoch, G.
    Heusch, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S502 - S502
  • [25] To enhance or not to enhance?: 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT
    Antoch, G
    Freudenberg, LS
    Beyer, T
    Bockisch, A
    Debatin, JF
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 : 56S - 65S
  • [26] Evaluation of 18F-FDG uptake and arterial wall calcifications using 18F-FDG PET/CT
    Ben-Haim, S
    Kupzov, E
    Tamir, A
    Israel, O
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (11) : 1816 - 1821
  • [27] 18F-FDG PET/CT in Bladder Cancer
    Tagliabue, Luca
    Russo, Giovanna
    Lucignani, Giovanni
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (12) : E522 - E524
  • [28] 18F-FDG PET/CT in the Management of Aortitis
    Bruls, Samuel
    Courtois, Audrey
    Nusgens, Betty
    Defraigne, Jean-Olivier
    Delvenne, Philippe
    Hustinx, Roland
    Moutschen, Michel
    Sakalihasan, Natzi
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (01) : 28 - 33
  • [29] PET/CT with 18F-FDG in the evaluation of Sarcomas
    Jover-Diaz, R.
    Vicente-Bartulos, A.
    Lourido-Garcia, D.
    Gorospe-Sarasua, L.
    Montero-Navas, A.
    Garcia-Poza, J.
    Ortiz, E.
    Pozo, M.
    Nunez-Miller, R.
    Alfonso-Alfonso, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S444 - S444
  • [30] Abdominal gossypiboma in PET / CT with 18F-FDG
    Sanchez-Aguilar, Marta
    Javier Garcia-Gomez, Francisco
    Caballero-Gullon, Luis
    IMAGEN DIAGNOSTICA, 2018, 9 (01): : 29 - 30