Luminosity monitoring and calibration of BLM

被引:0
|
作者
薛镇 [1 ,2 ]
许咨宗 [1 ]
汪晓莲 [1 ]
胡涛 [2 ]
王至勇 [2 ]
傅成栋 [2 ]
鄢文标 [1 ]
吕军光 [2 ]
周莉 [2 ]
蔡啸 [2 ]
俞伯祥 [2 ]
方建 [2 ]
孙希磊 [2 ]
石峰 [2 ]
王志刚 [2 ]
安正华 [2 ]
孙丽君 [2 ]
刘宏邦 [2 ]
章爱武 [2 ]
王晓东 [2 ]
机构
[1] Laboratory of High Energy Physics,Department of Modern Physics,University of Science and Technology of China
[2] Institute of High Energy Physics,Chinese Academy of Sciences
关键词
luminosity; luminosity monitor; EEMC; Bhabha scattering; cross-section;
D O I
暂无
中图分类号
O572.214 [];
学科分类号
070202 ;
摘要
The BEPC Luminosity Monitor (BLM) monitors relative luminosity per bunch.The counting rates of gamma photons,which are proportional to the luminosities from the BLM at the center of mass system energy of the ψ(3770) resonance,are obtained with a statistical error of 0.01% and a systematic error of 4.1%.Absolute luminosities are also determined by the BES End-cap Electro-Magnetic Calorimeter (EEMC) using Bhabha events with a statistical error of 2.3% and a systematic error of 3.5%.The calibration constant between the luminosities obtained with the EEMC and the counting rates of the BLM are found to be 0.84±0.03 (×10 26 cm-2.count-1).With the calibration constant,the counting rates of the BLM can be scaled up to absolute luminosities.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] K-band calibration of the red clump luminosity
    Alves, DR
    ASTROPHYSICAL JOURNAL, 2000, 539 (02): : 732 - 741
  • [22] Calibration of gamma-ray burst luminosity indicators
    Liang, Enwei
    Zhang, Bing
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2006, 369 (01) : L37 - L41
  • [23] USE OF TRIGONOMETRIC PARALLAXES FOR CALIBRATION OF LUMINOSITY SYSTEMS - THEORY
    LUTZ, TE
    KELKER, DH
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1973, 85 (507) : 573 - 578
  • [24] Direct calibration of the Cepheid period-luminosity relation
    Lanoix, P
    Paturel, G
    Garnier, R
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1999, 308 (04) : 969 - 978
  • [25] Emittance scans for CMS luminosity calibration in Run 2
    Karacheban, O.
    Cekmecelioglu, Y. C.
    EUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2019, 2020,
  • [26] Luminosity monitoring in ATLAS with MPX detectors
    Sopczak, A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [27] CdTe photoconductors for LHC luminosity monitoring
    Rossa, E
    Bovet, C
    Meier, D
    Schmickler, H
    Verger, L
    Mongellaz, F
    Rumen, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 488 - 493
  • [28] BACKGROUND AND LUMINOSITY MONITORING AT THE CERN ISR
    HEMERY, JY
    LEMEILLEUR, F
    OLSEN, R
    POTTER, K
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 145 - 145
  • [29] A Cherenkov Detector for Monitoring ATLAS Luminosity
    Sbrizzi, A.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2011, 215 : 232 - 234
  • [30] BACKGROUND AND LUMINOSITY MONITORING AT THE CERN ISR
    HEMERY, JY
    LEMEILLEUR, F
    OLSEN, R
    POTTER, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3034 - 3036