Luminosity monitoring and calibration of BLM

被引:0
|
作者
薛镇 [1 ,2 ]
许咨宗 [1 ]
汪晓莲 [1 ]
胡涛 [2 ]
王至勇 [2 ]
傅成栋 [2 ]
鄢文标 [1 ]
吕军光 [2 ]
周莉 [2 ]
蔡啸 [2 ]
俞伯祥 [2 ]
方建 [2 ]
孙希磊 [2 ]
石峰 [2 ]
王志刚 [2 ]
安正华 [2 ]
孙丽君 [2 ]
刘宏邦 [2 ]
章爱武 [2 ]
王晓东 [2 ]
机构
[1] Laboratory of High Energy Physics,Department of Modern Physics,University of Science and Technology of China
[2] Institute of High Energy Physics,Chinese Academy of Sciences
关键词
luminosity; luminosity monitor; EEMC; Bhabha scattering; cross-section;
D O I
暂无
中图分类号
O572.214 [];
学科分类号
070202 ;
摘要
The BEPC Luminosity Monitor (BLM) monitors relative luminosity per bunch.The counting rates of gamma photons,which are proportional to the luminosities from the BLM at the center of mass system energy of the ψ(3770) resonance,are obtained with a statistical error of 0.01% and a systematic error of 4.1%.Absolute luminosities are also determined by the BES End-cap Electro-Magnetic Calorimeter (EEMC) using Bhabha events with a statistical error of 2.3% and a systematic error of 3.5%.The calibration constant between the luminosities obtained with the EEMC and the counting rates of the BLM are found to be 0.84±0.03 (×10 26 cm-2.count-1).With the calibration constant,the counting rates of the BLM can be scaled up to absolute luminosities.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Luminosity monitoring and calibration of BLM
    Xue Zhen
    Xu Zi-Zong
    Wang Xiao-Lian
    Hu Tao
    Wang Zhi-Yong
    Fu Cheng-Dong
    Yan Wen-Biao
    Lue Jun-Guang
    Zhou Li
    Cai Xiao
    Yu Bo-Xiang
    Fang Jian
    Sun Xi-Lei
    Shi Feng
    Wang Zhi-Gang
    An Zheng-Hua
    Sun Li-Jun
    Liu Hong-Bang
    Zhang Ai-Wu
    Wang Xiao-Dong
    CHINESE PHYSICS C, 2011, 35 (01) : 1 - 5
  • [2] The energy calibration of BGO system for luminosity monitoring
    Liau, Jiun-Jie
    Chen, Yu-Tan
    Lin, Kuan-Po
    Lin, Fa-Hui
    Shiu, Jing-Ge
    Wang, Ming-Zu
    2015 International Symposium on Next-Generation Electronics (ISNE), 2015,
  • [3] PETRIE HGAMMA LUMINOSITY CALIBRATION
    HOAG, AA
    ASTRONOMICAL JOURNAL, 1968, 73 (10P2): : S184 - &
  • [4] Beam imaging and luminosity calibration
    Klute, M.
    Medlock, C.
    Salfeld-Nebgen, J.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] The luminosity calibration of the uvby -: β photometry
    Jordi, C
    Luri, X
    Masana, E
    Torra, J
    Figueras, F
    Domingo, A
    Gómes, AE
    Mennessier, MO
    HIGHLIGHTS OF ASTRONOMY, VOL 12, 2002, 12 : 684 - 687
  • [6] DETECTOR CALIBRATION, LUMINOSITY MONITORING, AND SEARCH FOR AN E-STAR AT DESY-HERA
    COURAU, A
    KESSLER, P
    PHYSICAL REVIEW D, 1986, 33 (07): : 2028 - 2030
  • [7] CALIBRATION OF GRB LUMINOSITY RELATIONS WITH COSMOGRAPHY
    Gao, He
    Liang, Nan
    Zhu, Zong-Hong
    INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 2012, 21 (02):
  • [8] Emittance scans for CMS luminosity calibration
    Karacheban, Olena
    Tsrunehev, Peter
    XXII INTERNATIONAL SCIENTIFIC CONFERENCE OF YOUNG SCIENTISTS AND SPECIALISTS (AYSS-2018), 2019, 201
  • [9] ASTROSTATISTICS FOR LUMINOSITY CALIBRATION IN THE GAIA ERA
    Palmer, M.
    Luri, X.
    Arenou, F.
    Masana, E.
    MILKY WAY UNRAVELLED BY GAIA: GREAT SCIENCE FROM THE GAIA DATA RELEASES, 2015, 67-68 : 271 - 274
  • [10] Luminosity monitoring and measurement at CDF
    Cronin-Hennessy, D
    Beretvas, A
    Derwent, PF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (01): : 37 - 50