Effects of supply air temperature and inlet location on particle dispersion in displacement ventilation rooms

被引:0
|
作者
Yanming Kang
机构
基金
中国国家自然科学基金;
关键词
Displacement ventilation; Particle dispersion; Numerical simulation; Supply air temperature; Inlet location;
D O I
暂无
中图分类号
X513 [粒状污染物];
学科分类号
摘要
The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. The results indicate that the temperature and vertical location of inlet supply air did not greatly affect the air distribution in the upper parts of a DV room, but could signiflcantly influence the airflow pattern in the lower parts of the room, thus affecting the indoor air quality with contaminant sources located at the lower level, such as particles from working activities in an offlce. The numerical results also show that the inlet location would slightly influence the relative ventilation efflciency for the same air supply volume, but particle concentration in the breathing zone would be slightly lower with a low horizontal wall slot than a rectangular diffuser. Comparison of the results for two different supply temperatures in a DV room shows that, although lower supply temperature means less incoming air volume, since the indoor flow is mainly driven by buoyancy, lower supply temperature air could more efflciently remove passive sources (such as particles released from work activities in an offlce). However, in the breathing zone it gives higher concentration as compared to higher supply air temperature. To obtain good indoor air quality, low supply air temperature should be avoided because concentration in the breathing zone has a stronger and more direct impact on human health.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 50 条
  • [1] Effects of supply air temperature and inlet location on particle dispersion in displacement ventilation rooms
    Kang, Yanming
    Wang, Youjun
    Zhong, Ke
    PARTICUOLOGY, 2011, 9 (06) : 619 - 625
  • [2] Effects of supply air temperature and inlet locations on particle dispersion in a displacement ventilated room
    Kang, Yanming
    Wang, Youjun
    Zhong, Ke
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 991 - 998
  • [3] Effect of source location on particle dispersion in displacement ventilation rooms
    Zhong, Ke
    Kang, Yanming
    Wang, Youjun
    PARTICUOLOGY, 2008, 6 (05) : 362 - 368
  • [5] Vertical temperature gradient and ventilation efficiency in rooms with displacement ventilation - influence of supply air temperature and heat load
    Department of Architectural Engineering
    Technol Rep Osaka Univ, 2348 (179-188):
  • [6] CFD study on effect of the air supply location on the performance of the displacement ventilation system
    Lin, Z
    Chow, TT
    Tsang, CF
    Fong, KF
    Chan, LS
    BUILDING AND ENVIRONMENT, 2005, 40 (08) : 1051 - 1067
  • [7] Effect of air supply temperature on the performance of displacement ventilation (Part II) - Indoor air quality
    Lin, Z
    Chow, TT
    Tsang, CF
    Fong, KF
    Chan, LS
    INDOOR AND BUILT ENVIRONMENT, 2005, 14 (02) : 117 - 131
  • [8] Effect of air supply temperature on the performance of displacement ventilation (Part I) - Thermal comfort
    Lin, Z
    Chow, TT
    Tsang, CF
    Chan, LS
    Fong, KF
    INDOOR AND BUILT ENVIRONMENT, 2005, 14 (02) : 103 - 115
  • [9] Investigation of Air Distribution in Mosque Rooms with Different Angles of Supply and Inlet Velocity
    Harsito, Catur
    Permata, Ariyo Nurachman Setiya
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1383 - 1388
  • [10] Effects of air temperature and humidity on particle deposition in a ventilation duct
    Han, Yun-Long
    Hu, Yong-Mei
    Qian, Fu-Ping
    Tumu Jianzhu yu Huanjing Gongcheng/Journal of Civil, Architectural and Environmental Engineering, 2010, 32 (04): : 66 - 70